Tweet
Contents.
Introduction
1.
Description of Colliery and Method of Working
Explosives
Haulage
Ventilation
Safety Lamps
Management
Persons Employed and Organisation of Shifts
Inspections before and during work
Precautions against Coal Dust
2.
Narrative of Events leading up to Explosion
(a) Operations to combat fire prior to the stopping of the colliery
(b) Operations to combat fire subsequent to the stopping of the colliery
3.
Cause of the Explosion and point of origin
4.
Gas in the Low East, Top East and Middle East Districts
(a) Prior to the commencement of damming off operations
(b) Gases on the return side of the fire during damming off operations
(c) Firedamp on the intake side of the fire during damming off operations from the 24th July to about 1 p.m. on the 27th July
(d) Firedamp on the intake side of the fire during the 20 hours preceding the explosion
27th July, 1 p.m. to 7 p.m.
27th July, 7 p.m. until midnight
From midnight on 27th July to the time of the explosion (9.15 a.m., 28th July)
5.
Arrangements for ventilating points where sealing off operations were in progress
6.
Supervision of operations
7.
Conclusions
8.
Irregularities as regards Statutory reports on the condition of the mine
9.
General system of working at the colliery
10.
Recovery of the 26 bodies still in the mine
11.
General remarks as to the Rescue Operations
Appendix I. — List of Persons who lost their lives in the Explosion
Appendix II. — Results of Analyses of Air Samples taken in the Mine (22nd to 27th July)