Museum Entrance Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Disaster Report Text
Disaster Report Name Index
UK Disaster Report Text
UK Disaster Report Name Index
Inquest Texts
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious

Reports Prev Page Return to Index Next Page Reports
Index

Report on the causes of, and circumstances attending, the explosion which occurred at Glyncorrwg Colliery, Glamorganshire, on 13th January, 1954

The Right Honourable Geoffrey Lloyd, M.P.,

Minister of Fuel and Power.

March, 1955.

Sir,

Introductory

In accordance with your instructions given under the terms of Section 82 of the Coal Mines Act, 1911, I beg to submit my report on the causes of, and circumstances attending, the explosion which occurred at the Panzer Face in the Six Feet Seam at Glyncorrwg Colliery, Glamorganshire, on 13th January, 1954, when 24 persons were injured. In no case did the injuries prove fatal.

I. — Description Of The Colliery

General

Glyncorrwg Colliery is situated near the village of Glyncorrwg, about 9 miles north-east of Port Talbot, and has been a working mine Since 1904. The output is about 800 tons of coal per day and the numbers of persons employed are 633 below ground and 150 on the surface.

The mine is served by two vertical shafts. The South Shaft is the downcast, 18 feet in diameter, and sunk to the Six Feet Seam at a depth of 407 yards. It is the main winding shaft for men and mineral. The North Shaft is the upcast, 16 feet in diameter, sunk to the Red Vein Seam at a depth of 428 yards, and equipped with a Waddle fan producing about 143,000 cubic feet of air per minute at a water gauge of 7.2 inches.

Management

The mine is in the No. 2 Area of the South Western Division of the National Coal Board and the principal officials are as follows :—

Area General Manager Mr. A. T. Minhinnick.
Area Production Manager Mr. S. B. Bassett.
Sub-Area Production Manager Mr. F. Stacey.
Group Agent Mr. W. Moore.
Manager Mr. E. L. Powell.
Assistant Manager Mr. R. J. Evans.
Undermanager Mr. G. Thomas.

Seams Worked and Lamps Used

The seams worked, in descending order, are the Six Feet, Nine Feet and Peacock. Safety lamps have always been required to be used throughout the mine but automatic detectors are not required by the Regulations to be provided, there being no electric power in use at any of the longwall faces and no "broken" workings. The lamps in general use throughout the mine are Oldham G.W. electric cap lamps, with E. Thomas and Williams Cambrian No. 9E flame safety lamps for use by workmen as firedamp detectors. Cambrian No. 2A flame safety lamps are used as officials' inspection lamps.

The Six Feet Seam

The seam has an average thickness of about 7 feet 6 inches, including two thin bands of dirt. It has a roof of shale and a floor of weak fireclay. The volatile content of the coal on an ash-free dry basis is 102 per cent.

Work in this seam was started about five years ago and the full extent of the workings is shown on Plan 1. The seam was reached by driving two cross-measure drifts from intake roadways in the Nine Feet Seam and another cross-measure drift from a return airway in the Peacock Seam. The development in the seam consisted of a double-unit longwall face advancing north-east with two intakes and a return at the left side. The area proved to be geologically disturbed with faults, patches of barren ground and irregular gradients. Eventually, the development face was stopped at a fault of about 30 feet displacement.

Attempts to win out faces to advance south-east on the right flank of the development face proved unsuccessful due to barren ground until, towards the end of 1952, one such face was set away in normal ground. This face, known as the Panzer Face, and drivages to form a similar face adjacent to it, were the only active workings in the seam at the time of the explosion.

 

Prev Page Return to Top of Page Next Page


mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.
Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 31 Dec 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z