Museum Entrance Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Disaster Report Text
Disaster Report Name Index
UK Disaster Report Text
UK Disaster Report Name Index
Inquest Texts
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious

Reports Prev Page Return to Index Next Page Reports
Index

VII. — Intrinsically Safe Remote Control Circuits

43. The drilling machine involved in this explosion was of a type first certified as flameproof in 1953 and was fitted with a rectifier for "pilot-earth" protection. This rectifier had been removed to enable the machine to be used with a drill panel having a remote control circuit which did not include "pilot-earth" protection. This drill panel incorporated a remote control circuit operating at 25 volts for which a test certificate of intrinsic safety (T/RC/l) was issued during 1939. This certificate was granted following tests carried out at the Safety in Mines Research Board testing station at Sheffield. The test procedure adopted was believed, at the time, to represent the most dangerous conditions of circuit interruption. From about 1940 further research in connection with intrinsic safety was undertaken and it was found that under a more modern method of testing some doubt was cast upon the safety of this and a number of other remote control circuits.

44. From 1940 to 1946, 11 ignitions, causing the death of 13 persons and injuries to 13 others, occurred in connection with the use of electric drilling machines underground.

45. Each of the 11 accidents presented certain disturbing features, two of which were common to each case, namely,

 (1) 
local defects in the ventilation arrangements, accompanied by failure on the part of those immediately concerned to detect and appreciate the potential danger; and
 (1) 
a concurrent electrical defect which resulted in open sparking.

The attention of the owners and managers of all mines under the Coal Mines Act, 1911, and of the secretaries of National and Local Associations of Owners, Officials and Workmen was drawn to these matters in Ministry of Fuel and Power Safety Circular No. 148, dated 25th September, 1946, which referred to intrinsically safe remote control circuits, and No. 153, dated 30th December, 1946, which referred to electric drilling machines. Details were given of each accident and of the precautions which should be taken to avoid similar types of accident. The Chief Inspector and the Principal Electrical Inspector in their reports covering the years 1939 to 1946, and the Principal Electrical Inspector in his reports for the years 1949, 1952. 1953 and 1954 called attention to these circulars.

46. I think it is important that I should quote the recommendations contained in the circulars in full because the explosion at St. John's might not have occurred if the precautions which were then recommended had been observed.

M.F.P. Safety Circular No. 148

Intrinsically Safe Remote Control Circuits

 "1. 
There can be no dangerous sparking unless a remote control circuit is deliberately or accidentally interrupted at contacts which are exposed to the atmosphere. The deliberate bridging of pilot and earth contacts, when the plug has been withdrawn from the socket, as a means of testing the operation of the remote controlled switch should be avoided.
 "2. 
A remote control circuit includes an earthing conductor. Care should be taken to see that it is not interrupted by loose connections or faulty contact between the parts of a plug and socket coupler, and the continuity of the earthing conductor should be tested at frequent intervals.
 "3. 
Plug and socket couplers are likely to be subjected to very rough handling. They should be examined daily and replaced as often as may be necessary, and in so far as this is practicable dispensed with altogether.
 "4. 
Finally, there can, of course, be no danger of a firedamp explosion unless firedamp is present in the air. Therefore, look after the ventilation. This is specially important in fast ends, particularly if driven to the rise, where electric drilling machines may be used."

M.F.P. Safety Circular No. 153

Electric Drilling Machines

The Circular emphasised the importance of :—

 "1. 
a high standard of ventilation being maintained in all places where electric drills are used, particularly right up to the roof at a ripping lip;
 "2. 
the use at all times of suitable firedamp detectors by properly trained competent workmen;
 "3. 
frequent and thorough examination of all drilling equipment by properly appointed and qualified electricians;
 "4. 
proper care of drilling machines and their associated apparatus by all workmen operating them, who should be thoroughly instructed in their use;
 "5. 
full regard to the precautions necessary in handling the remote control apparatus associated with electric drilling machines, as outlined in M.F.P. Safety Circular No. 148."

47. Until such time as appropriate modifications could be made in the design of remote control circuits and such modified circuits were generally available, it was considered that the risk, if any, of allowing existing circuits to remain in use could be controlled by observing the precautions which had been recommended.

48. A large number of these remote control circuits are still in use and are likely to remain so for some time. As long as they do remain in use the recommendations in the Safety Circulars of 1946 will hold good. All persons concerned with the installation or operation of apparatus which incorporates these remote control circuits should ensure that these recommendations are fully implemented. For general guidance I would point out that remote control circuits with certificate numbers less than T/RC/31 have been found by modern methods of testing to be suspect.

49. Ignitions of firedamp caused by drilling machines incorporating the older types of remote control circuit occurred in this Division in 1952 and 1954. As a result of correspondence between my predecessor and the Production Director of the North Eastern Division of the National Coal Board, the Board carried out a review which showed that in 1955 there were still in use 1,005 of these electric drilling machines with remote control circuits on the safety of which doubts had been cast: these were being gradually replaced by new or modified types. By the time the St. John's explosion took place, 512 had been replaced or modified and rather less than half of those in use in 1955 were still in use. If these are replaced or modified at the same rate it will be five years before they have been eliminated from the Division.

50. The hazard presented by the use of apparatus which incorporates this early type of remote control circuit is not confined to the North Eastern Division. The amount of such apparatus in use throughout the whole country must be very large. It is however important that its use should be discontinued. I therefore recommend that the National Coal Board and any other mine owners who may be concerned should review the position and then arrange for the withdrawal of this apparatus, giving priority to that used for drilling which presents the greatest hazard.

 

Prev Page Return to Top of Page Next Page


mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.
Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 31 Dec 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z