VIII. — Summary Of Conclusions
51. My conclusions are summarised as follows : —
| | 1. |
The explosion was one of firedamp initiated in the pilot heading being driven to win out the right side of 1's face (Paragraph 32).
|
| | 2. |
At the time of the explosion steps had not been taken for securing that there was constantly produced in the heading, ventilation adequate for diluting gases that were inflammable so as to render them harmless and to remove them in accordance with Section 55 of the Mines and Quarries Act, 1954 (Paragraph 36).
|
| | 3. |
The igniting agent was an incendive spark at the flange gap of the plug and socket coupling of a drilling machine which was being used at the time to bore a shot hole (Paragraph 30) in a place in which inflammable gas, although not normally present, was likely to occur in a quantity sufficient to be a danger (Paragraph 35).
|
| | 4. |
The scheme for systematic examination, maintenance and testing of all electrical apparatus at the mine was not being fully implemented (Paragraph 42).
|
| | 5. |
The recommendations contained in M.F.P. Safety Circulars Nos. 148 and 153 in regard to the use of electrical apparatus incorporating the type of remote control circuits described therein were not observed (Paragraph 46).
|
IX. — Acknowledgments
52. I welcome this opportunity of expressing my sincere thanks to the representatives of all organisations, members of the staff of the Safety in Mines Research Establishment as well as members of my staff, who assisted in the investigation of this explosion and in the preparation of material for this Report.
I have the honour to be, Sir,
Your obedient Servant,
H. J. Perrins.