Museum Entrance Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Disaster Report Text
Disaster Report Name Index
UK Disaster Report Text
UK Disaster Report Name Index
Inquest Texts
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious

Reports Prev Page Return to Index Next Page Reports
Index

IV. — THE CAUSE OF THE EXPLOSION

The Practical Investigation

All the safety lamps, both flame and electric, in use in the district when the explosion occurred were sent in the condition in which they were brought out of the mine to be tested at the Safety in Mines Research Establishment. No defect was found in any lamp which would cause it to be a risk of ignition of methane.

The telephone system throughout the mine and the signalling bell and relay used in connection with the haulage in the Top Level were likewise tested and found to be in conformity with approval specifications. There was no other electrical apparatus involved.

The auxiliary fan for the ventilation of the cul-de-sac in the Top Level was found to be well earthed so as to preclude the possibility of a static charge of electricity, and there was no evidence of friction which could have caused heat or sparking. All other possible causes of frictional heat were ruled out after due consideration.

An examination of all the compressed-air equipment revealed no leakage which might have caused heating.

There was no shred of evidence pointing to smoking or the use of a naked light.

There remained the possibility that the shots fired in the Carrier Gate rippings might have ignited firedamp which continued to burn in bed separation cavities and roof breaks until it reached an explosive mixture over an hour later. Air samples taken for the purpose of testing this theory gave entirely negative results, and after consideration of all factors involved this possible cause was also ruled out.

The Evidence of the Injured Persons

When those injured in the explosion had recovered sufficiently for statements to be taken from them, their evidence pointed conclusively to the Companion Road as the point of origin of the explosion. All who were in the Carrier Gate or on the face between the Carrier Gate and the Companion Road at the time said a blast of flame came down the face and out into the Carrier Gate against the air current; all who were on the return side of the Companion Road said a searing blast came up the face and outbye along the Top Level.

The evidence of those who were in or about the Companion Road at the time confirms this and also points conclusively to a Thomas & Williams Cambrian "Midget" Internal Igniter flame safety lamp as being the igniting medium under the following circumstances

A few minutes prior to the explosion, John Beauchamp, an assistant surveyor, took a tripod into the Companion Road and set it near the entrance to the Arcade. He had with him an electric cap lamp and a "Midget" flame lamp. Both lamps were lit when he entered the road from the face, but when he came to put the Midget lamp on the tripod he found the flame extinguished. Attempts to relight it were unsuccessful, so he went back to the roadhead and exchanged it for the surveyor's "Midget" lamp which was lit. The flame of this lamp also was extinguished before he reached the tripod, so he used his cap lamp to illuminate the head of the tripod and the surveyor sighted the spindle.

Beauchamp then attempted to relight this second Midget lamp. At the first attempt there occurred what he took to be a "fuel pop" inside the lamp. He blew into the bonnet of the lamp to clear it of the products of combustion and then made a second attempt. This time, to use his own words, "the place just seemed to go on fire. As I turned the key it automatically started."

An assistant repairer, T. Palczykewycz, who was standing a few yards away watching Beauchamp, is equally positive that the explosion originated at this Midget lamp instantaneously with the operation of the relighter mechanism.

The Cambrian "Midget" Internal Igniter Lamp

In the light of this evidence, further exhaustive tests were carried out by the Safety in Mines Research Establishment on the suspect lamp and the others of the same type. These tests were designed to cover the additional hazards arising from particles ground from the pyrophor bars by the operation of the relighter mechanism. In view of the fact that there was a slight leakage from the fuel vessel of the suspect lamp, the tests also covered the hazards arising from the presence of spirit vapour. Numerous experiments were carried out under all conditions which might be presumed to have prevailed at the time of the explosion, but all attempts to stage an external ignition failed.

Experiments were also carried out by the Research Establishment to determine (a) the size distribution of pyrophor particles produced by the normal operation of the relighter mechanism of a Midget lamp, and (b) the minimum size of particle which would, on combustion, liberate sufficient heat energy to ignite a mixture of methane and air. These experiments proved that a particle of sufficient size to cause ignition was occasionally produced, and that such a particle could pass through, or become lodged in, an aperture in either of the gauzes of a safety lamp. The probability of ignition by means of a pyrophor particle was found to be greatest when the methane/air mixture contained 5.5 per cent. methane.

Conclusions

My conclusions are as follows :—

(1) There was a mildly explosive mixture of methane and air in the Companion Road throughout the time it was being surveyed, and it was this which caused the flame safety lamps carried by John Beauchamp to be extinguished.

(2) This explosive mixture was ignited by the Thomas & Williams' Cambrian "Midget" Internal Igniter flame safety lamp when John Beauchamp made his final attempt to relight it.

(3) This external ignition was not due to any defect in the lamp but was the result of an abnormal effect of pyrophor ground off by the operation of the relighter mechanism.

(4) The explanation which I consider most feasible is that a previous operation of the relighter mechanism, at a time when the lamp contained an inert atmosphere, had ground off a particle of pyrophor of sufficient size to ignite a mildly explosive mixture of methane and air, and that this unburnt particle had become lodged in the outer gauze in contact with the external atmosphere. On the final operation of the relighter mechanism, this particle was ignited either by being struck by an incandescent particle of pyrophor or, more probably, by the heat generated by a mild explosion inside the lamp.

(5) Coal dust played no part in the propagation of the explosion. This was probably due to the effectiveness of the measures adopted for the prevention and suppression of airborne dust coupled with the fact that stone and not coal was being conveyed on this shift.

(6) It is probable that accumulations of firedamp lying back in the wastes were forced out on to the face line in the initial stage of the explosion and caused its spread to the extent indicated.

 

Prev Page Return to Top of Page Next Page


mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.
Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 31 Dec 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z