III. — NARRATIVE OF THE EXPLOSION
Discovery and First Exploration
The first person outside the affected area to discover the occurrence was the afternoon shift overman, Charles Jones, who was sitting having his food near the loading point on the Carrier Gate when, at about 6.30 p.m., he felt a violent blast of air from the direction of the face and a momentary reversal of the air current. He realised at once that an explosion had occurred, and with commendable coolness and efficiency he immediately telephoned to the surface, informed the manager and asked for rescue and ambulance services to be summoned, and then telephoned for help and additional stretchers from the districts nearest to L.21.
Two deputies, E. Williams and I. Jones, quickly responded to the call for help, and reached the loading point just as the first of the injured men arrived there from the face of the Carrier Gate. Deputy B. Williams, who was highly skilled in first aid, took charge of the treatment of the injured while overman Charles Jones with a few volunteers went inbye to explore the district.
They found the air current to be taking its normal course and the ventilation adequate except in the Companion Road where the air was foul with thick fumes right to the ripping lip. They extinguished several small fires where discarded articles of clothing were burning or smouldering in the Carrier Gate, along the face and in the Top Level, In the Top Level they found the dead body of deputy Arthur Griffiths, badly burned with the clothing still on fire. All the other persons employed at the face on this shift had sustained burn injuries, but all were fully conscious, able to walk and were making their way off the face. Deputy George Greenhaf, despite his injuries, insisted on remaining until the last.
The Path of the Explosion
(a) Effects of the blast. There was evidence of the passage of flame along the full length of the face, outbye for about 30 yards along the Carrier Gate and 50 yards along the Top Level including the cul-de-sac hauler house, and throughout the Companion Road and Arcade. There was no evidence of violence or the effects of force, and only very slight coking on a few props on the face. All the indications were that the explosion had been one of firedamp and that coal dust had played no part in its propagation. There was no visual evidence to indicate the probable point of origin of the explosion.
(b) Inflammable gas. In the cul-de-sac off the Top Level, a feeder of firedamp was issuing as described earlier in this Report. There were also small accumulations in a few roof cavities above the steel arches on the Top Level in this vicinity.
When the fumes cleared from the Companion Road an accumulation of firedamp was left. This was found to be the result of a small feeder issuing from bedding planes in the strata above the seam which had been exposed when the ripping of this road was commenced. It needed careful bratticing so as to divert part of the face air current right to the back end of this road in order to dilute the feeder near its point of issue. The Arcade airway immediately after the explosion was only 18 inches to 2 feet high.
Air samples taken about two hours after the explosion showed that the air current was carrying its normal methane content of about 0.25 per cent. at a point 10 yards on the return side of the face, but about 1.25 per cent further outbye near the fault.