VI. — Cause Of Cut Belt
As already mentioned, the cause of the grooving and subsequent cutting of the belt had not been ascertained from the examinations made before the occurrence of the fire. Nor did the investigations underground after the fire reveal the cause. Experiments were therefore made to see if it was possible to determine the probable cause. The gear-head of the No. 2 conveyor was re-erected on the surface to operate a short length of conveyor. It was known that the No. 2 belt transported stone from rippings and that, among this stone, pieces of ironstone were occasionally found. Pieces of shale and pieces of ironstone, both from the South-West District, were held firmly and fed to the belt as it passed over the delivery roller. It was found that pieces of shale cut into the belt but soon splintered after several yards of belt had passed. As the shale was fed in, a cutting edge developed that was capable of cutting through two plies of canvas for a distance of little more, than 50 feet. The chances of a piece of shale cutting evenly through 500 or 600 yards of belt to a depth of seven plies of canvas seemed very remote. When a piece of ironstone, however, was used, a cut of precisely even depth for a length of 200 feet — the limit of belt available in the experiment — was obtained. A shorter cut, but also to the limit of the length of belt available, was also obtained to a depth of six plies of canvas and part way into the seventh. After cutting, the ironstone was just perceptibly warm to the touch and, apart from being blackened by rubber, was practically unworn. It seemed evident that a piece of ironstone suitably wedged would be capable of continuing indefinitely to cut a belt to an even depth. It is important to note that although a belt was readily cut in this way, the appearance of the cut — even in broad daylight — gave no clue as to its depth. The belt had to be suitably flexed to determine the depth of cut.
From these experiments, a reasonable explanation of the damage and cutting of the No. 2 belt as found after the fire would appear to be as follows. A piece of ironstone had settled at the top of the No. 2 chute — probably due to a pile-up of stone when the No. 1 belt stopped while the No. 2 belt was still running — and became wedged against the No. 2 belt. At first it caused the "sloughings" and then, settling into position it caused the 8 inches long hole, cutting the belt right through to the delivery drum. The edge in contact with the steel drum became worn away, or the stone may have shifted slightly, so that it remained in a position to cut nearly through the belt.