Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious

I.M.E. Previous Return to Index Next I.M.E.
/   \

Volume 9 (IX), 1860-1861, published 1861

William Gardiner, miner — I was at work in the East Minor Pit on the day of the explosion, down the east bank, about 770 yards from the shaft. Whilst we were working, near nine o'clock, a mighty rushing of wind came upon us — it blew our lights out. I went up the bank first and met the stythe, and then came back and went by the return to the furnace, and then towards the shaft, but we were obliged to turn back again, and then we went hack to the furnace and staid till Mr. Daglish and others came to us; we then went down the return and through to the Eppleton Pit and got out. We found the after-damp first on going up the east bank — it was going from the shaft — it was very strong. Shortly after the explosion, the direction of the air was reversed, and soon afterwards it was again reversed. I have seen the damage done by the explosion. I am not able to form an opinion where the explosion took place, or the cause of it. There was no accumulation of gas in the workings that I know of. The ventilation where we were working was in full operation. I cannot form any opinion where the gas came from which caused the explosion. The air where we were working was good up to the time of the explosion.

Ralph Hope, miner — I was in the East Minor Pit at the time of the explosion, at the east bank. After it had taken place, I and William Gardiner, Robert Gardiner, Joseph Scott, William Anderson, and Thomas Smith were together. We went first up the east way towards the shaft. We met the after-damp a good bit down the bank — it was very strong. From the effects of the after-damp, I cannot recollect which direction we took. I was insensible, and was carried out of the pit. The after-damp was going inbye when we met it, from the shaft. Up to the time of the explosion the air was good where we were working. There was no gas there at the time. I have no idea how the explosion took place. I considered the pit perfectly safe before it.

Robert Simpson, shifter — On the day of the explosion, I was working down the east bank of the East Minor Pit. After the explosion, I went up the east bank. We met the after-damp coming from the shaft, a good bit down the bank, it was very strong. We came back and went into the return drift, and proceeded to the East Minor shaft. We got out by the Eppleton Pit. Up to the time of the explosion, the air where we were working had been very good. There was no gas. I cannot form any opinion as to where the explosion took place, nor the cause of it. I had previously considered the pit perfectly safe.

John Bond, wagon way man — On the day of the explosion, I was working in the north cross-cut, down the east bank of the East Minor Pit. Before the explosion, the air was very good. There was no gas. I considered the pit perfectly safe. We were working with two oil lamps. One of them was blown out by the force of the explosion. We proceeded to the east bank, and met with the Gardiners and Smith. We first met the after-damp at the bottom of the bank, where we came out from the north cross-cut end, about 600 or 800 yards from the shaft. It was not strong there. It was coming in the direction from the shaft. It got stronger as we proceeded towards the shaft up the east bank. We were obliged to return. We proceeded up the return to the shaft. We remained there eight or nine hours, and then got out by the Eppleton Pit. It was the main wagonway where I was working in the first of the air. If I had considered there was any danger, I would not have gone down that night, but I thought I was as safe as I am standing here. We were working about 800 yards from the shaft. The force of the explosion threw me and my mate down. The place where we were was six feet high and eight feet broad. There was only one blast of wind.

George Gleghorn, pitman — I was working with John Bond in the north cross-cut of the East Minor Pit, at the time of the explosion. We had two naked oil lamps. The force of the explosion threw us both down, and blew out one of our lamps. Before the explosion the air was very good. There was no gas where we were. I considered the pit perfectly safe. We met the after-damp nearly at the top of the east bank, it was very strong, and coming in the direction from the shaft. I am not able to give an opinion as to where the explosion took place, or the cause of it.

Robert Gardiner, hewer — On the day of the explosion, I was at work with my brother on the east bank of the East Minor Pit. Before the explosion the air was very good — there was no gas. We met the afterdamp a little up the bank. It was very strong when we got about three parts up the bank. It was coming from the shaft. We got up the Eppleton Pit. I cannot form the least opinion as to where the explosion took place, or the cause of it.

William Anderson — I am a stone workman, and was at work in the East Minor Pit, on the 20th of December last, at the north cross-cut, down the east bank. When the explosion took place the air was very good. We found little effect from it, merely a ringing in our ears. We would be about a mile and a quarter from the shaft. I have heard of no gas in any of the goaves that could have caused it. My opinion is if it had come from the goaves to the furnace the furnace would have been blown to pieces, and it is undamaged.

James Reed — I am master wasteman of the East and West Minor Pits. I was down the East Minor Pit on the morning of the day of the explosion. I went down at half-past two o'clock in the morning, to set my men to work. After I set the men to work, I went in the wagonway of the East Minor to the bottom of the new south incline, into the return. I met George Lowden at that point, to arrange about some stores ha wanted, and I then went into the waste, and examined further in than is shown upon the plan. The ventilation was capital — in a real good state. There was no accumulation of gas; I do not believe an inch. I examined every part of the returns of that pit up to the furnace, and found nothing but well, all ways. I left the pit about a quarter-past eight o'clock in the morning. I examined all the places that morning, and they were all clean. I have examined many a time the place where the explosion is supposed to have occurred. I am of opinion it took place in the flues. I think it had been gas in the flues, but I cannot tell how or why it had come there. It could not I think, possibly have come down the downcast shaft, and so got to the flues. If the ventilation was perfect, gas accumulated in the workings could not get to the flues, nor even if it was imperfect. I know no other place where it could come from, except the coals put on the engine fire for damping. There were some repairs done in the upcast shaft. They commenced on the Sunday before the explosion, and concluded on the Tuesday previous. The wedging of the tubbing had given way, and some water was going down the pit, which interfered with the ventilation, hut not to any considerable extent. The ventilation was perfect again on the Wednesday morning. These repairs could not in any way have assisted in causing the explosion. The principal returns were examined on the Wednesday morning, but I found not the slightest gas. Whilst the repairs were going on in the shaft, the High Main furnace was going in full operation. The two west furnaces in the Hutton Seam were also going, but not in full operation. The east furnace was out, or nearly so. and the three boiler fires were on to a certain extent. The dampers were down, but the fires were not damped. [Mr. Reed then explained the mode of repairing the tubbing.] During the stoppage we had as much ventilation as before the furnaces were put out. Before recommencing work the High Main was examined, and there was no gas in any of the edges of the goaves. I examined the intake and the outtake of the Low Main myself but not inbye, and I found her clean. I have known the Low Main twenty-three or twenty-four years, and never saw an inch of gas in her. It gives off less gas than the other seams. I do not think that gas, during these repairs, can have accumulated to any extent in any part of these pits. If it had been, I do not see the possibility of its getting to the flues with the benefit of the portion of air going to Eppleton from the Minor Pit, which supplied the east, north, and west districts of the East Minor Pit, which was a benefit to the West Minor Pit. What the Eppleton Pit upcast took was a benefit to the West Minor Pit. At the time of the explosion I think we would have 157,668 cubic feet per minute going down. That was measured a fortnight before the explosion. It does not surprise me, with that quantity of air, that there has been so much after-damp from the explosion. I know, of my own knowledge, that men have been suffocated, at considerable distances, in all directions from the shaft. I have travelled some distance underneath after-damp, but not a considerable distance. The furnaces, after the explosion, did not assist to make after-damp. The burning of the hay in the stables I think would. It made a serious quantity of smoke. I do not think any man could have lived where it was very strong for any length of time. I believe there has been no other gas, except what was in the flue, to cause this explosion. There was no possibility of gas getting from the Low Main to the flues, because the flues were shut off altogether, and it could only get through the damper, and would have to pass over the fire, and, although damped, would have exploded, and gone back to the Low Main. Gas generated in the Low Main would make for the upcast. If gas came down the downcast shaft, and so over the fire, it was impossible for it to get into the flues. If it did, it would pass No. 1 and No. 2 boilers before it came to the flues. No. 8 boiler has flues: the others have none. I do not think it possible for any gas to come down the downcast, from the quantity of air we had. There was no goaf to foul from in the east, and the returns were examined in the west, and no gas found. I think it is possible, with so large a quantity of air, when the ventilation is broken, to have as much afterdamp as in this explosion.

George Lowden recalled — After the stoppage, on the Sunday previous to the explosion, I examined the whole of the driftways, but found no gas. I examined the waste, and the workings which belong to us, but not the stables. They are the only part I did not examine, and they are in the first intake of the air. It would not be possible for gas to accumulate there.

George Davison, engineman — I had charge of the engine in the east side of the East Minor Pit. I took charge of it at four o'clock in the morning, and continued in charge up to about ten minutes to five o'clock in the afternoon. Up to that time my engine had gone all right, and the ventilation also. The fire was damped when I left. I did not examine the steam valves, but I examined the steam gauge immediately before I left; it indicated 18lbs. on the square inch. It might have been worked at 33lbs. on the square inch — that is the ordinary pressure. The damper was out a little to take away the smoke. I think it would not be more than an inch and a half open. I did not see the damper, but ascertained by the weight and chain attached to it, which I did see. The fire would be damped by the fireman, William Clennell. After the fire is damped I think it will give off less smoke than before. I cannot say that damping would cause more gas. After a time it would give off more smoke. There was a little scale of fresh air from the top of the damper. I did not hold my lamp to it that day before I left the pit. A week after the explosion I saw my boiler and engine. The boiler was standing in the same place where I had left it. I examined it that day by looking round it. It had not been displaced. I have not examined it inside. I had examined the boiler before I left on the day of the explosion, but there was no leakage. The smoke would go through the scale left under the damper and so into the flues. The draught was only sufficient to take away the smoke "cannily" into the flues. The fire was damped in the usual way. The opening of the damper is regulated by guess, according to one's own idea of the space required. The damper could not have been nearly down without my knowing — the smoke would come out in a contrary direction. If the damper was down to the bottom there might be a bit scale at the sides, but it would not take away the smoke. The grooves in which the damper worked were formed of fire-bricks, and not metal, and there was a small leakage into the flue. The brick grooves would not fit the damper as perfectly as metal — it would admit more space for gas to get into the flues. I cannot say anything about gases. It is the first time I have heard of or seen fire behind my engine. I have been an engineman twenty-four years, and had charge of this engine two years. I never knew a case of gas firing behind the damper, nor in front of it. I have seen a little on the fire — a bit "flisk." When the damper was in and was lifted it gave a bit explode. That was at bank. My damper was not broken when I left it before the explosion, but is so now. I think it might be broken by an explosion of gas inside the flues. If the damper was put too close, the draught would have come back. There was always sufficient draught to prevent back draught through the fire doors. The fire doors were open when I left, and every thing else was left as usual, and, as I considered, perfectly safe. No alteration has taken place in the boiler or the flues for some time. About ten months ago the boiler was repaired and the side flues built up again in the same way as before. During Monday and Tuesday previous to the explosion I was at my boiler. I was driving the engine on these days pumping water. I was pumping water by the force pump out of the Hutton Seam to the main coal. My engine worked night and day these two days. Once before, when cleaning the drift out, about three weeks before the explosion, she went three nights and days, and nothing unusual occurred. I have examined my flues since the explosion, and see they are blown up in two places. I think it was gas in the flues that caused the explosion. I cannot say where the gas came from. We had plenty of air coming to the fire on the Monday and Tuesday, and I saw no difference on the Wednesday, and on the Thursday it was coming just the same. The fire burned sharper in cold weather. We do not put the damper further down than in hot weather. Two or three hours after being damped a flame might play about the fire. The fire is sometimes green when damped. At the week's end we burn her down to damp. I think there would be more cinder than green coal on when she was damped. There was a little flame playing over the top after she was damped that night, at the backside. There is sufficient flame at the backside to explode fire-damp if it came back from the flue. If the same gas as is made in the gas works was in the flues, and had come back upon the fire, it would have lighted. There was nothing to prevent the damper falling down. I never cleaned the framework of my damper. Dirt might accumulate, and dust also. The distance from the firebars to the damper is about sixteen or eighteen feet. There is a flue with an end door to it at the entrance to the boiler, on the right hand side. The door was kept open always. The air might get in there. It had no connection with the centre or smoke flue. There was no opening into the centre flue that I know of. If gas was coming in at the door and over the fire, if it came in contact with the flame it would ignite. I am quite sure my damper was not left half-way up that night. As soon as the fireman puts the fire in he damps it, and I see if it is right. One night it might be half an inch lower than another without my knowing it. I think about a tub of coals, which is eight cwts., is required to damp the fire. On returning in the morning, eleven hours after, I cannot say more than a quarter of it would be burnt. The fire burns more to the back, and in the morning there is both cinder and green coal. When we commence to damp, there may be a tubful of fire on the grate bars. The flame at the back of the fire was not peculiar to that night. There is generally a little flame there.

Prev Page Return to Top of Page Next Page

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 31 Dec 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print