E. Thomas and Williams Type G2 (Garforth) LampsAppendix III to
 EI/G(70)5

INSTRUCTIONS FOR MAINTENANCE

1. Dismantling

Unlock the lamp by placing the plug of the magnetic lock on to a suitable unlocking magnet, when the lock bolt will be withdrawn and the fuel vessel can be removed by unscrewing it from the lamp frame. Next, place the lamp frame over a fixed bench key so that the holes on the underside of the brass glass-seating ring are engaged and unscrew the lamp frame. The gauzes, glass, and washers can then be removed from the lamp for inspection and cleaning.

2. Filling

The fuel container is packed tightly with Cotton Wool. Remove the screw Stopper on the shoulder of the container and pour in spirit until the wool will absorb no more. Invert the container to drain off surplus spirit (on no account should free liquid be allowed to remain in the container) and replace screw Stopper. Wipe top of container dry. Care should be taken to see that the fuel is perfectly clean and no dirt should be allowed to enter the fuel container.

The only fuels permitted for use are N.C.B. Relighter Spirit No. 1 or No. 2, Shell-Mex S.P.B.4 and Rubber Solvent.

3. Gauzes

Inner and outer gauzes, which must be of 28's mesh, must be examined and cleaned inside and out, after every working shift. If a gauze is damaged, or if some wires appear thinner than others, it should be replaced. For cleaning use the special gauze cleaning brush available from stock. Note that new gauzes are coated with a solution to protect against rust and there will be some smoke when these new gauzes are first used in a lit lamp.

4. Glass

Glasses which are cracked, or chipped on the top or bottom face, must not be used. The Glass should be examined daily and cleaned inside and out.

Note Lamp fuel must not be used for cleaning glasses.

5. Washers

Both top and bottom washers of asbestos must be in good clean condition. Make sure they are correctly positioned when assembling lamps.

6. Wick and Cotton Wool

The wick must be kept clean and will seldom need trimming and only very rarely need replacing. To replace the wick, or re-pack with cotton wool, first unscrew the re-lighter key in a clock-wise direction then unscrew the Burner Plate keep-ring and lift out the entire top of the fuel container. The Wick Tube is then exposed and can be removed by screwing off the adjustment bar so that the new wick can be threaded through the tube and the unit re-assembled. This process also exposes the "O", sealing ring around the secondary sample intake. If there is any sign of leakage this should be checked and, when necessary, replaced.

7. Fuel Vessel

Clean dirt from the top. Make sure that the wick adjusting button on the base of the lamp turns easily and that the wick can be turned up freely and turned down to a testing flame position.

8. Garforth Chamber

Any crust or dirt round the top of the burner tube or in the top of the "Garforth" chamber should be cleaned off daily using a dry rag with the fuel vessel in an inverted position. If the incrustation is not easily removed, a rag slightly moistened with relighter spirit may be used — again with the fuel vessel inverted, so that neither dirt nor fuel will enter the Garforth chamber. On no account should the crust be removed by abrasives such as wire brushes, emery cloth etc.

Note New burner tubes made of stainless steel will shortly be available and which will be more resistant to erosion. The new tubes will project above the top of the thimble by at least 0.080 inch and maintenance of this height should ensure freedom from condensation.

9. Sealing Rings and Gasket

In addition to the "O" Ring referred to under para. 6 there is another on the Adjustment Bar and another inside the sampling socket. If leakage occurs the adjustment bar "O" Ring may also have to be checked and, if necessary, replaced. To do this the Adjustment button in the base of the lamp must be removed by melting the solder with a hot iron and screwing off the Button then the process described in para. 6 should be followed and the Adjustment Bar and Wick Tube can be lifted clear and the "O" Ring exposed. The "O" Ring inside the sampling socket can be visually checked and, when necessary replaced. The gasket which seals the fuel vessel and the relighter spindle tube should be checked and replaced if hardened, permanently distorted or otherwise damaged.

10. Relighter

Ensure that the flint and the striker wheel are dry and that the striker wheel serrations are clear. A small brass wire cleaning brush is available for this purpose. The pyrophoric bar or flint is adjusted by means of the small grub screw at the end of the relighter block.

ONLY APPROVED PYROPHORIC BARS SUPPLIED IN SEALED PACKETS TO BE USED.

Operate the relighter after cleaning as follows: first raise the wick approximately in. by means of the adjusting button in the base of the lamp: turn the key in the base of the lamp in an anti-clockwise direction to a stop and then let the fingers slip off the key very quickly. The spring leaded spindle then snaps back and drives the striker wheel against the flint. Adjust the flame to a convenient height immediately.

11. Assembly

Place the brass glass-seating ring on a fixed Bench Key so that the holes in the underside of the ring are engaged. Place an Asbestos Washer, Glass, Asbestos Washer, and pair of Gauzes upon the glass-seating ring and lower the lamp frame over this assembly to engage the threads of the glass-seating ring — which should then be tightly screwed up into the lamp frame, thus securing the inner fittings. The glass-seating ring must be tightly screwed home to retain the inner fittings firmly in position. In a properly assembled lamp it will not be possible to rotate the glass by finger pressure: any such movement indicates incorrect assembly and it should be dismantled, examined and re-assembled. Finally screw on the full vessel tightly. Verify that the lock is preventing reverse rotation of the fuel vessel.

12. Daily Testing

The Garforth system is tested by injecting a sample of fresh air by means of a bulb fitted with a brass nozzle and restrictor (a Garforth Bulb) after adjusting the wick to give a small testing flame, and observing the effect on the flame. The air sampled in the bulb for this test should be taken well away from any relighter spirit fumes, and the bulb should be squeezed firmly and steadily so as to empty the bulb in about 5 seconds. With a system in good condition, the testing flame will flatten and the yellow eye decrease in size or disappear completely.

If there is any distortion, such as pulling up of the edge of the flame, check that the wick tube and the edges of the Garforth chamber are clean; If these are satisfactory a new (clean) sintered bronze ring should be fitted. To remove the sintered ring, dismantle the lamp, and unscrew the milled cap from the top of the Garforth chamber surrounding the wick and remove the sintered ring. The new sintered ring can then be placed round the wick tube, pressed firmly but evenly on to its seating, and finally tightened by screwing home the milled cap.

If the nozzle of the Garforth bulb does not seal properly in the sample inlet socket, in the base of the lamp, the "O" ring should be replaced with a new one.

Check that the component parts of the Garforth bulb i.e. nozzle, restrictor, and the bulb itself are in good order.

13. General

 (i) 
Lamp Bonnet. Frequent hammering out of dents weakens the metal. Replace if in doubt.
 (ii) 
Do not allow lamps to be issued with bent standards.
 (iii) 
All magnetic locks to be tested before issue.
 (v) 
Thinning down of vessel walls mostly due to over buffing should be avoided.
 (viii) 
Regulator tube must be perfectly free in movement.
 (ix) 
Quantity of lamps available should be watched, as inadequate supplies can result in double shifting and ultimately 'skipping' of examination.
 (x) 
Manufacturers 'Name, Type and Approval No.' Plates must be replaced if damaged or obliterated.