Wolf Flame Safety Lamps Type FG (Garforth)Appendix II to
 EI/G(70)5

INSTRUCTIONS FOR MAINTENANCE

1. Fuel and Fuel Consumption

Rubber solvent Spirit or Equivalent (NCB Spec. No. 303, Relighter Spirit Type 2 or 1).

First filling 3fl.ozs. Subsequently 1½ to 2fl. ozs. depending on how long lamp has been burning. Fully filled lamps will burn 12/14 hrs. with ½in, flame.

2. Unlocking

Unlock the lamp by placing the two poles of the magnetic lock to a Wolf Unlocker, when the nose of the rocking bar will be withdrawn and the vessel can be removed by unscrewing it from the top. Care should be taken to hold the lamp glass with the finger and thumb as there is no retaining ring for glass and gauzes. Place the top with its inside fittings on the bench, take the knurled cap on the top of the lamp vessel between the finger and thumb and remove the vessel cover to which it is attached.

3. Filling

Fill from a Wolf Filling Can until the felt pads will absorb no more fuel. Lamps must not be over-filled, i.e. there must be no free fuel. Check by turning the lamp vessel upside down, allow to drain for a minute or two and shake gently to remove excess fuel.

Care should be taken to see that the fuel is clean from the time it leaves the container in which it is supplied till it enters the lamp vessel. Only clean cans which have not be used for any other purpose should be used for lamp fuel and rubber tubing should not be used. No dirt should be allowed to enter the lamp vessel. Spirit fuel should not be kept in glass vessels (except in small quantities) and should not be exposed to light.

After filling, replace the vessel cover so that the wick tube and inlet pipe slip in to the mating tubes and press down.

4. To Light the Lamp

The wick adjusting screw is turned right to lower and left to raise the wick. To light the lamp, which is fitted with a self-contained cerium relighter, first raise the wick, then fold down the relighter key underneath the lamp vessel, twist the key clockwise and pull down. If the lamp fails to light the first time, the operation must be repeated. Underground, spirit-burning lamps are usually warm and light easily. Lamps should be lit in the lamp room and burned for one hour immediately prior to issue. The wick, when lit, should be lowered a little below the smoking point and, as the flame will rise when the lamp warms up, should be lowered again after a few minutes, if necessary. If a lamp does not light at the first attempt, it can be cleared by swinging, blowing into it at the middle ring or blowing air through with the Garforth bulb, When the lamp has been lit, remove the relighter key, which is attached to the spindle by a screw fitting. The key should be carried separately by the Official. (The first time a new lamp is lit, there may be some smoke due to burning off of the coating which is used to preserve the gauzes from rust.)

5. To Extinguish the Lamp

Lower the wick to slightly below the level of the burner tube and give the lamp a sharp downward movement. Always leave the wick turned down when the lamp is not lit.

6. Cleaning

All internal parts should be kept perfectly clean and dry and care should be taken to see that both glass washers are in correct position when assembling.

7. To Clean Garforth Fittings

Any encrustation on the top of the wick, wick tube and burner tube, should be cleaned off daily with a dry cloth, holding the parts in an inverted position. If it is set hard, wipe the parts clean with a cloth moistened with lamp fuel, again with the cover plate in an inverted position. Do not use abrasive devices such as wire brushes, emery cloth etc.

It is recommended that the Garforth filter and knurled cap holding it in position should not be interfered with so long as the lamp functions satisfactorily.

The nozzle on the Garforth bulb is fitted into the ¼m. I/D, outer tube underneath the lamp vessel and the sample is fed through the centrally placed inner tube, which is straight and so can be easily cleaned by blowing through it, or, if very dirty, by using a piece of wire.

8. To Change the Garforth Filter

Remove the knurled cap and lift the filter out by inserting the point of a pen-knife blade into the exposed edge at three equally spaced points around the filter. Take care not to damage the brass housing or burner tube when removing the filter. See that the recess into which the filter fits and the inside of the knurled cap are clean and no particles of the old filter remain. Take a new filter with rounded edges down, and push down evenly round the burner tube until the filter has just entered the recess. Screw the cap back as tightly as possible over the filter, burn the lamp for 15 minutes and tighten the cap down as far as it will go. Test as described below.

9. Wicks

Lamp wick does not need trimming on spirit burning lamps unless the lamp has been allowed to burn dry or the wrong fuel has been used, but it must be kept clean. Where trimming is necessary, it should be done evenly with scissors. IT IS IMPORTANT in this lamp that the wick is so fitted, or trimmed, that it is level with or no more than approx. in, above the top of the wick tube. Replacement of a wick presents no difficulty; the correct length for replacement is 9 inches (23cm) of 9/32 in. (7mm) round wick of special Wolf type.

10. Inner and Outer Gauzes

Examine after every working shift and clean inside and out with the fibre brush provided. Wire brushes must not be used.

11. Glasses

Examine after every working shift and clean inside and out. Glasses which are cracked or chipped on the top or bottom face must not be used.

Note Lamp fuel must not be used for cleaning glasses.

12. Washers

In all Wolf Flame Safety Lamps, compressed asbestos fibre washers are used at the top and bottom of the Approved Type glass. These should be kept clean and replaced if damaged. Particular attention must be paid to ensure that the bottom washer is free of contamination by fuel or other solvent.

13. Relighter Mechanism

The pressure of the Approved type flint against the friction wheel is adjusted by means of a grub screw and spring fitted in the relighter casting, near the top. It is at this point that a new cerium piece is inserted when needed. The friction wheel can be cleaned with a wire brush or with a pen-knife blade and its position on the spindle should be changed from time-to-time. Check regularly that the screws retaining the relighter mechanism are a tight fit and will not permit the escape of fuel or fuel vapour.

14. Absorbent Filler Pads

The cotton wool filling in these lamps has now been replaced by felted pads. When fitting a pad it is desirable that a small gap should exist between the top of the pad and the underside of the fuel vessel cover plate to ensure that the cover plate is not in direct contact with fuel.

15. Fuel Vessel Cover Plates

The material from which the cover plates are manufactured is absorbent to a degree and may permit the diffusion of fuel vapour into the flame chamber with the possibility of 'false cap' readings. Until non-absorbent cover plates are available, existing cover plates will be coated with epoxy resin on the underside to render them impermeable to fuel or fuel vapour.

The treatment will be carried out by Scientific Department, or at Central Workshop.

16. To Check a Lamp after Assembling

Hold the lamp glass between finger and thumb and try to turn it. If it can be just moved the lamp is correctly assembled.

17. Daily Testing

The Garforth system, when assembled, is tested by feeding an air or gas/air sample into it using a Garforth bulb. The tube to which the nozzle of the Garforth bulb is fitted when feeding a sample into the lamp is between the wick adjusting knob and the relighter key. When fresh air is used, with the flame in the testing position, the flame will be slightly lowered or flattened and should remain even all round. When a gas/air mixture is used, an even cap should be visible, on which there is no sign of distortion.

The air sampled in the bulb for this test should be taken well away from any relighter spirit fumes and the bulb should be squeezed firmly and steadily so as to empty the bulb in about 5 seconds. If there is any distortion of the flame check that the wick tube and the edges of the Garforth chamber are clean; if these are satisfactory a new filter ring should be fitted.

Examine the Garforth bulb and check that its component parts i.e. nozzle, restricter and bulb itself are in good order.

18. General

 (i) 
Lamp Bonnet. Frequent hammering out of dents weakens the metal. Replace if in doubt.
 (ii) 
Do not allow lamps to be issued with bent standards.
 (iii) 
All magnetic locks to be tested before issue.
 (v) 
Thinning down of vessel walls mostly due to over buffing should be avoided.
 (viii) 
Regulator tube must be perfectly free in movement.
 (ix) 
Quantity of lamps available should be watched, as inadequate supplies can result in double shifting and ultimately 'skipping' of examination.
 (x) 
Manufacturers 'Name, Type and Approval No.' Plates must be replaced if damaged or obliterated.

Prev Page Return to Top of Page Next Page