The parts of face workings and roadheads to which the provisions of Part IV apply are defined in Regulation 11, and the extents of the face working with various methods of working are shown in Figs. 12(a), (b) and (c).
Different provisions, as regards support spacing, are made for faces on which an armoured conveyor is used (Reg. 12) and those on which there is no armoured conveyor (Reg. 13). Faces on which armoured conveyors are used are divided into two classes, those on which persons do not work on the face side of the conveyor other than occasionally or for short periods — the prop-free front — and those on which more regular or prolonged work has to be done there.
For prop-free fronts, the maximum interval, to be specified in support rules, between rows of props is 3½ feet, and that between the front row of props and the face is 6½ feet. The intervals between adjacent props m the same row depend on the two above figures. If the specified interval between the front row of props and the face does not exceed 6 feet, props in the same row may be 5 feet apart, but if it exceeds 6 feet, props in the same row must not be more than 4½ feet apart. These maximum intervals are desirable to allow some flexibility, but if they were all specified for the same face, the prop density would be too low. To avoid this, provision is made that the sum of the specified intervals between rows of props and between props in a row may not exceed 7 feet where the distance between the front row of props and the face may not be greater than 6 feet, and may not exceed 6½ feet where the distance between the front row of props and the face may be greater than 6 feet.
However, under the terms of Regulation 14(2), bars may not be more than 4 feet apart, unless they are arranged on what is known as the triangular system with bars in adjacent rows about half a bar length apart, in which case the distance between corresponding bars may be 5 feet. This affects the spacing of props in a row if pairs of bars are set side by side as shown in Fig. 13(a). If the interval A between the front row of props and the face may not exceed 6 feet, then the sum of B, the interval between rows of props, and C the interval between props in a row, may not be more than 7 feet; B may not be more than 3 feet 6 inches and C may not be more than 4 feet. If the limit of A is 6½ feet then B plus C may not be more than 6½ feet. Fig. 13(b) shows a triangular system; the same limiting distances apply, except that the distance between bars, and so between props in a row, may be 5 feet.
The permissible spacings, which are already widely adopted, are not easy to explain in words, but are shown in detail in the following table.
Where persons do much work on the face side of an armoured conveyor, for example, as on most faces on which coal is loaded by a flight loader or in the stables of power loader faces generally, the maximum distance between the front row of props and the face is 3½ feet, but the permissible intervals between supports are somewhat greater than those for prop-free fronts, though less than those for faces on which there is no armoured conveyor. The maximum intervals are 4 feet between adjacent rows of props and 3½ feet between adjacent props in the same row (Fig. 14), except that whilst the conveyor is being advanced the distance between adjacent rows of props may be up to 7 feet for a length of face not greater than 30 yards.
Where power loaders are fitted with a pre-cutting jib, the length of face on which the distance between the front row of props and the back of the precut is greater than 6½ feet shall not be more than 20 yards (Fig. 15). The armoured conveyor will have to be advanced and the supports set close behind such machines.
As power loaders can move rapidly, the Regulations prohibit a power loader from approaching within 30 yards of a place where the support operations of the previous strip are incomplete (Fig. 16). This restriction does not apply to machines, such as coal ploughs, taking strips not greater than 15 inches deep.
If abnormal conditions make the approved props ineffective, the manager may specify the temporary use of unapproved props in the part of the face concerned. A change in seam thickness might make it impracticable to use the approved props available, and if the roof is poor, their replacement by expendable types of prop, which could be left in the waste, might be in the interest of safety. Fig. 17 shows a face on which the height has increased. Wooden props have been substituted for the hydraulic props and, to prevent the roof in the waste breaking forward, they have been left in place. If unapproved props are in use for more than seven days, notice has to be given to the inspector for the district.
If at any part of a face powered supports are made ineffective by abnormal conditions, the manager may specify the use of approved hand-set supports in accordance with Regulation 12, or, in the circumstances considered in the previous paragraph, the temporary use of unapproved props.
On longwall faces on which armoured conveyors are not used and in workings other than longwall faces (Reg. 13), the maximum intervals between props remain 6 feet between rows of props (4 feet if bars are not used) and 4 feet between props in the same row, and the limit of 3 feet between the front row of props and the face, after filling or loading has been completed, is unchanged (Fig. 18 (a) and (b)).
Concerning the setting of bars in face workings and roadheads (Reg. 14), all props or chock-props set in compliance with the Regulations, that is, all except those set as temporary supports or as extra supports, must be set under a bar, and the bars must extend over the whole width of the face working or roadhead. However, exceptions as stated below are made.
Bars need not be set in face workings where machinery is not used for cuffing, conveying or loading. Where the height of the roof from the floor in a face working is not, or is usually not, greater than 2 feet, bars are not required, provided that the props are so spaced that the sum of the interval between adjacent props in the same row and that between adjacent rows of props is not more than 7 feet. This does not, of course, prevent the setting of bars in thin seams, but whether greater safety is got by setting bars or by spacing the props more closely is left to the judgment of the manager.
Tolerances are provided close to the face, mainly to allow for the safe passage of machines. On a face where an armoured conveyor is used and persons do not work on the face side of it other than occasionally or for short periods, there may be a distance of 18 inches between the ends of the bars and the face provided the bars are approved bars. In all other circumstances a distance of 12 inches must not be exceeded.
Bars are not required to be set in the path or travel of an overcutting machine and, so that bars have not to be set across the roof steps often formed by an overcutting machine, an interval of up to 1 foot is allowable between the ends of adjacent rows of bars if such a machine is used (Fig. 19).
The part of the roof adjacent to a waste behind the front line of the packs need not be supported with bars (Fig. 20). The object of this is to avoid having bars extending farther into the waste than a row of chocks. Generally the backs of the chocks should be in line with the bar ends, but in some cases, as in Fig. 20, the roof breaks are so positioned that the roof blocks they create are less likely to fall if the chocks are behind the bars.
Bars generally must, of course, be supported by at least two props, but coupled bars of an approved type need be supported by only one prop provided that each is connected to another propped bar, and the front bar in each line of coupled bars may be a cantilever (Fig. 21).
Slide bars must be mounted on at least two props, fitted with approved bar slide heads, which must give effective support to the roof even when the bars are being moved forward, so that if a slide bar cannot be advanced without disturbing its props, another bar should first be set alongside it.
As regards spacing in a roadhead, props, which must have bars above them, must not be more than 4 feet apart in each direction (Fig. 22). If the main girders are set parallel with the face and the depth of undercut is about 4½ feet or more, two girders should be set for each cut in order not to exceed the 4 feet spacing; this can best be done on the unit system as shown in Fig. 23. At a place where an armoured conveyor is used in a roadhead, the interval between props in a row must not exceed 3½ feet.
As before, supports may be removed or their setting delayed as is necessary to make way for machinery. Under Regulation 20, the removal or the delay should be for as short a time as practicable, and the roof must be supported all the time by effectively propped bars. If the distance between the props on each side of the machine is ever more than 7 feet, the bars must be single bars rather than coupled; therefore, over the wider types of conveyor gear head (Fig. 24) and at the entrance to stables, except where the power loader takes only a narrow strip, single piece bars must be used.
The limit of 4 feet is also applied to the spacing of arch girders in roadheads, except for the parts of roadheads outbye of the roadside pack fronts.
As in the previous regulations, extra supports must be set at rippings (Reg. 17). Formerly, a bar was required to be set close to the ripping lip (Fig. 10). This is still acceptable but it has been found that, especially where the main bars are at right angles to the face, other forms of support, such as chock-props, may be better than a lip bar, and these may now be used, as shown in Fig. 25. The roof newly exposed by ripping must be forthwith effectively supported. This is generally done by forepoling from the arch girders nearest the face (Fig. 10). For this to be satisfactory, the girders carrying the forepoles must be fully tightened. Arch girders set on stilts yielding at a very low resistance and those set on soft floor without footpads or on debris cannot carry effective forepoles, In some circumstances, pre-loading of the arch girders may be necessary to ensure that the newly exposed roof is satisfactorily upheld. Ripping faces must, as previously, be supported. The support of a ripping face by "L" bars is illustrated in Fig. 10 and in Fig. 26 it is shown done by bolting.
The manager must specify the amount of ripping that can be done at any one stage. Under Regulation 22, the maximum face advance before advancing the packs is limited to 7 feet, and where, as is usual, the roadside packs are built with ripped stone, this will limit the amount of ripping that can be done at once to 7 feet.
Except on prop-free fronts temporary supports must be set systematically during the process of filling or loading (Reg. 18). Where the coal is worked on the front, temporary props must be set not more than 3 feet in advance of the front row of props and at the same intervals as the props in the front row (Fig. 27(a)). Where the coal is worked on the buttock a temporary prop must be set when the distance between the nearest bar and the coal is more than 3 feet (Fig. 27(b)). In a narrow place, that is, one other than a longwall face, the newly exposed roof must be forthwith effectively supported. Temporary props will generally be used for this purpose, and they should be set, not more than 4 feet apart, when the distance between the front row of props and the coal exceeds 3 feet (Fig. 27(c)). However, where propping is impracticable, as when the roof line is curved or is very high, other means such as forepoling may be used to support the newly exposed roof. On a prop-free front, temporary props are not required to be set systematically but only if anyone is working or passing on the face side of the conveyor, when he must have a temporary prop within 3 feet of him; this is intended for the personal protection of those working for short periods on the face side of the conveyor. If, to clear debris over a few feet of the face, such a person had to move along the face, he should set a second prop before removing the original one (Fig. 27(d)). The conditions of most exemptions did not require temporary props to be set if persons had to cross the conveyor to set bars; the new Regulations do not include this concession, because there are now available devices which enable bars to he set from the goaf side of the conveyor. If powered supports fitted with cantilevers approved for the purpose are used, the temporary support may be given by the cantilevers.
As in the past, holing props or sprags must be set forthwith at intervals not exceeding 6 feet (Reg. 19), but two exceptions to this requirement are now made. Sprags may be necessary to prevent falls of coal and they help in the general roof control, but on prop-free fronts the risk in setting or removing them from across the conveyor may outweigh the advantages to be gained from their use and so they are not generally required on such faces. On some other faces, the coal breaks so freely as it is cut that it would be a hazard to persons setting sprags close behind the cutting machine. In such cases, the safest course may be to allow the coal to fall where it is weak, sprags being set later to the still upstanding stronger coal, and this procedure may be laid down in support rules.