The prop-free front system spread rapidly and now over 70% of the longwall faces are so worked. All these faces were operating under exemption from certain provisions of the old Regulations rather than under the Regulations themselves. The Minister therefore decided that the time had come to prepare new Regulations, to reduce the number of exemptions needed and to give statutory force to the best current practice. The Regulations were agreed after long consultations with representatives of the interested parties, who saw the importance of the Regulations to both safety and production.
The Regulations are divided into five parts. Part I includes interpretations. The existing Support Regulations are revoked, and consequently the exemptions there from lapse, but an Inspector is given power to issue exemptions from the 1966 Regulations. Part II indicates that the Regulations apply to mines of coal, shale and fireclay. Part III requires persons setting various forms of support to set them so as to be effective and to correct or replace them should that become necessary. Part IV is concerned with systematic support at faces and roadheads. Part V contains miscellaneous provisions, dealing with such matters as the treatment of cavities.
The effects of Parts III, IV and V are set out in detail below, but among the chief changes made by the new Regulations are the following. A limit is put to the extent of face advance before packing. Closer support is now needed at the roadheads of longwall faces. The roof newly exposed by ripping must now be forthwith effectively supported. Arch girders must be set securely, and, near the end of a line of arch girders, as at a ripping or a repair lip, means of preventing the girders from moving towards the open end are necessary. There are changes in the provision dealing with falls that have affected supports. The props used on faces where an armoured conveyor is used must be of an approved type and, if powered supports or coupled bars are used on such faces, they also must be of approved types. The informal arrangements for testing are put on a statutory basis; supports achieving fixed standards of performance in tests made, on a procedure laid down by the Minister, at the Central Engineering Establishment of the National Coal Board will be considered for formal approval by the Minister.
Anyone setting a prop anywhere in a mine must set it securely and on a proper foundation. When the floor is soft (Fig 2(a)) a prop may have to be set on a foot lid (Fig. 2(b)) or on a hard bed below the floor of the seam (Fig. 2(c)). In a level seam, a prop should be square with the roof and floor, but where the seam is inclined, experience shows that props are best angled between the vertical and a line at right angles to the seam (Fig. 3). Where there is a space between the roof and a bar above a prop (Fig 4(a)), that space should be filled tightly (Fig. 4(b)).
Anyone whose job includes prop setting must reset or replace any prop that appears to have become ineffective. A broken wood prop or a defective hydraulic prop must be replaced by a sound prop. A prop that has become unstable must be corrected; examples of instability are shown in Fig. 5 — a prop that has become insecure because of the crushing of timber packing (Fig. 5(a)), one set too near to a lip (Fig. 5(b)), one set on several foot lids (Fig. 5(c)), and one under a lip bar that is twisting outwards (Fig. 5(d)). If a faulty prop cannot be corrected or replaced, the deputy must be told immediately and he should take steps to ensure that matters are put right.
Lids are usually necessary above props in order to spread the load, to take up crushing and so avoid damage to props and bars, and to reduce the risk of the prop slipping from the bar. A lid set between a prop and a bar should cover the whole of the top of the prop. A lid set directly under the roof on a rectangular or a square prop must be at least as wide as the top of the prop and twice as long (Fig. 6(a)), and on a round prop must be at least as wide as the prop diameter and at least twice as long (Fig. 6(b)).
There are circumstances in which the advantages of using lids can be achieved in other ways. Lids need not be used under wooden bars (Fig. 7(a)), or over approved yielding props engaged to the bar by means preventing them from slipping (Fig. 7(b)). They are not required above such yielding props fitted with approved friction caps (Fig. 7(c)), though the conditions of approval of the friction caps will limit their use to faces on which the gradient is not more than 1 in 5. Lids are not needed on props set at the waste edge with the intention of causing the roof to break. In parts of a mine, away from working faces, where there is little convergence, a rigid steel prop may be fixed directly to a girder (Fig. 7(d)). Lids are not essential if wood props are set under corrugated bars where the working height does not, or does not generally, exceed 2½ feet — for in thin seams there is little convergence and a more secure setting of supports may be made if lids are not used. Lids are not required with approved types of bar slide head (Fig. 7(e)) or on chocks or chock-props having a top with a smallest dimension of not less than 9 inches.
Chocks must be tight to the roof (Reg. 8), and to this end must be on a proper foundation, not on debris, with big enough bearing surfaces against roof and floor and between any parts of the chock (Fig. 8). Round wood should not be used in a chock, because the contact areas between round pieces are small and would allow the chock to crush without much resistance.
Packs must be built tightly and spaces between the walling stones filled with small material to increase the bearing surfaces (Fig. 9).
Arch girders must be set on a proper foundation (Reg. 10): where the floor is soft, wood foot blocks are usually necessary and any stilts on which the girders are mounted should have sufficient resistance when they are first set as well as later. The girders must be made tight to the roof and sides and fixed to their neighbours to ensure that none can swing out. Struts set between the flanges of the girders serve this purpose except near the end of a line of arch girders, where some form of tie is necessary. Fig. 10 shows ties preventing a recently set girder from moving towards a face ripping, and Fig. 11 shows girders at a back ripping restrained from moving towards the repaired length by securing them with chains.