I. Description Of The Workings In The Cockshead Seam.
1. Mossfield Colliery is situated on the outskirts of the town of Longton at the South Eastern end of the North Staffordshire Coalfield.
2. There are two shafts, both sunk to a depth of 440 yards, which is about 20 yards below the Cockshead seam in which the explosion occurred. This seam dipping to the South West at about 1 in 3 is recovered by a level crut, 6o yards long, from the downcast shaft. Other seams, both above and below the Cockshead seam, are worked from the shaft, but since these seams were in no way affected by the explosion there is no need further to refer to them except to say that roads in one of them, viz., the Seven Feet Banbury seam, were used as part of the return airway for the Cockshead seam workings, as will be seen on reference to Plate I, which is a plan showing the general lay-out of the workings and the ventilation system in the Cockshead seam and in particular the district (15's Level) in which the explosion occurred.
Other plates attached to this report show :—
(1) the positions in 15's Level district in which the dead and injured were found when rescue parties reached them a short time after the explosion (Plate II).
(2) a plan of 15's district on a large scale showing the packs and wastes in the area between the coal face and the faulted part about 50 yards outbye of the face, together with a longitudinal section of the seam as worked; showing also the immediate roof strata, two faults, and a crut which was driven and abandoned when it failed to recover the seam on the inbye side of the inner fault which at first appeared to be a downthrow, but which later proved to be a reversed or overlap upthrow (Plate III).
3. Ventilation of 15's Level workings. — The coursing of the air to ventilate the face is shown in Plate I. The quantity of air measured in 15's Level on 23rd February at a point 100 yards outbye from the face was 4,900 cubic feet per minute. All this air, except what may have been lost by leakage through the packs and wastes inbye of the faults, passed up the face to the return airway. That there was some such leakage a few days before the occurrence will emerge later in section III.
A copy of this report was kindly donated by
West Cumbria Mines Research.