Ventilation And Occurrence Of Firedamp Before Explosion
The mine is ventilated by a Bumstead & Chandler exhausting fan passing a total quantity of 110,000 cu. ft. of air per minute with a 3 inches water gauge. From a measurement taken on the 5th May, 11,440 cu. ft. of air per minute were passing into the intake airway from the downcast pit bottom, but as already stated only 2,835 cu. ft. per minute were passing into the district at a point 100 yards from the first working place, the loss of 8,605 cu. ft. being due to leakages through the connexions between the main intake and the main return airways. This excessive leakage was known to the management and steps were being taken to deal with it, but little work had been done before the explosion. Since the explosion most of the leakages have been dealt with, and the air current entering the first working place in the district had increased to 6,450 cu. ft. per minute when a measurement was made on the 6th July.
The course of the air was directed by sheets hung in the roads in the positions shown on Plan 1, and by four separation doors, two in 335's road and two in the short road connecting 347's passbye with the intake airway. There was considerable leakage at the latter two doors which had suffered from crush. After the explosion the inbye door in 335's road was found open, but there is evidence that this door was in use on the previous day, and the door was probably jammed open by the rush of air at the time of the explosion.
The number of sheets employed, especially the sheets in 328's level, through which tubs were continually passing, must have led to a good deal of leakage from the face, and some leakage was actually allowed in order to ventilate the pillars which were being extracted, so that it is probable that while the air current in the face affected by the explosion was sufficient to keep the faces clear under ordinary conditions, it was not sufficient to deal with any exceptional circumstances which might arise.
Separation doors near the foot of 328's level and in 327's road would have been preferable to sheets, for any damage to the lowest sheet in 328's level or to the sheet in 327's road would have left only a single sheet between the face and the main return airway in a position where it would have had to withstand approximately half the ventilating pressure required to drive the air round the district, and the leakage of air under such conditions would be serious in its effect on the whole of the face affected by the explosion.
Firedamp had been reported by the deputies on three occasions during the previous twelve months, and when air samples were taken by one of H.M. Inspectors on the 16th February, 1933. at a time when the face was obstructed by a fall, a percentage of 1.06 was found in the general body of the air in the face near 333's road.
Later samples, taken on the 6th April, showed no firedamp on the face on the intake side of 335's road, but 0.76 per cent, in the return air in 340's level.
It will be seen therefore, that while the seam is not a gassy one, in the ordinary use of the term, the emission of firedamp may be expected, and in his evidence at the Inquest, the Manager, Mr. Latham, stated that when falls of roof occur on the face, the presence of gas may be looked for.
It was stated at the Inquest by more than one witness that the fan near the face of 360's level had served no useful purpose for some little time; it had been installed when 360's level formed a long narrow corner, at which time it had a use, and had been carried forward as the face advanced.