118. I recommend that:
| | (1) (a) |
polyurethane foam as at present constituted, whether or not treated with a fire-retardant coating, should not be used underground at any coal mine, or at the surface of any mine in such a situation that the products of its combustion would be likely to enter the mine;
|
| | (1) (b) |
any foam which has been placed in moving ground or in a situation where there is a spontaneous combustion hazard shall be removed immediately, or sealed off, or be given an adequate fire-retardant coating and removed within 12 months;
|
| | (1) (c) |
any foam which has been placed in a situation other than in (b) above shall be given an adequate fire-retardant coating and be removed as soon as practicable or sealed off. (Para. 104).
|
| | (2) |
The National Coal Board should review the present procedures for implementation of the Emergency Organisation (including charts posted in offices) and give specific instructions to managers that the senior official at the mine available at the time of an incident should be authorised, without prejudice, to call on the Rescue Station services and to declare an Area emergency. (Para. 108).
|
| | (3) |
The Board and H.M. Inspectors should examine the possibility of improving the checking systems. (Paras. 12 and 109).
|
| | (4) |
The methods of signposting all means of egress should be examined and a standard method instituted. (Para. 112).
|
| | (5) |
Overmen and deputies shall at least once in every month inspect and report on the state of every means of egress from the parts of the mine assigned to them. (Para. 112).
|
119. In order that action should be taken without delay on the above recommendations, your predecessor agreed that I should submit them to the interested parties and this was done in February, 1968.