Museum Entrance Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Disaster Report Text
Disaster Report Name Index
UK Disaster Report Text
UK Disaster Report Name Index
Inquest Texts
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious

Reports Prev Page Return to Index Next Page Reports
Index

II. — Description Of The Colliery

(3) Cardowan Nos. 1 and 2 Colliery is situated at Stepps in the County of Lanark about five miles north-east of Glasgow. It produces a daily output of approximately 1,500 tons of coal from four seams, the Meiklehill Main, the Meiklehill Wee, the Cloven and the Kilsyth Coking Coal. The latter, in which the explosion occurred, lies at a depth of approximately 700 yards from the surface. The mine is served by two shafts, No. 1 the downcast and No. 2 the upcast. In addition a third shaft, No. 3, has been sunk to a depth of 700 yards for the future development of the colliery but its existence has no bearing on this accident. During normal working prior to the accident a total of some 1,400 men were employed underground and 250 on the surface. The mine is gassy and safety-lamps are used throughout the workings. It is ventilated by a double inlet Sirocco fan situated on the surface at No. 2 Pit, which before the fire in January circulated a total quantity of 450,000 cubic feet of air per minute with a water gauge of 5.14 inches.

(4) The mine has a history of heavy gas emission. An explosion of firedamp occurred in No. 2 Shaft while it was being sunk in 1927, a second explosion occurred in 1931 while an underground fire in the Meiklehill Main Coal was being sealed off, and a third, in which 11 men were killed, occurred in 1932 in the same seam. This latter explosion was the subject of a formal investigation under Section 83 of the Coal Mines Act, 1911, conducted by Sir Henry Walker, then H.M. Chief Inspector of Mines, and a report Cmd. 4309 was published in 1933.

(5) The colliery is situated in the No. 3 (Central West) Area of the Scottish Division of the National Coal Board. The Colliery Manager was J. MacMaster and there were three undermanagers of whom J. B. Henderson was in charge of the part of the mine where the accident occurred. The Group Manager was W. G. Neilson, one of the injured persons; the Deputy Area Production Manager (Operations) J. Lawrie; the Area Production Manager J. R. Cowan; and the Area General Manager D. Lang.

 

Prev Page Return to Top of Page Next Page


A copy of this report was kindly donated by
West Cumbria Mines Research.

 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.
Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 31 Dec 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z