This accident occurred at a junction of putting roads in the Main Coal seam which was being worked in the whole whole below the goaf of the Hutton seam which is 11 feet thick and lies 15 feet from the Main Coal, the roof of which is consequently somewhat broken and wet and requires careful timbering. The road had become too low a few yards from the turn, and the two hewers inbye of the point had been called out to assist the deputy and deceased in making height. Operations had hardly begun and deceased was sitting at the turn when a stone 5½ feet by 3½ feet and 13 inches thick relieved by slips, fell upon him from the roof partially displacing two planks in its fall. Unlike the preceding case no running balk was used so as to better secure the roof at the turn. The Local Inspectors reported "we consider that it was a pure accident."
|
|||||||||||||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 31 Dec 2022
|