Chapter VIII

Some Regulations of particular importance to operators of coal cutting machinery

The extracts from Regulations made under the Mines and Quarries Act, 1954. contained in this chapter are only a selection of those which apply to you and your job.

You should make yourself familiar with the Act itself and its Regulations in order to understand your statutory obligations fully.

We give here some extracts from Regulations which affect the work of coal cutter operators. The dots . . .) indicate that words have been left out in order to simplify the reading of these Regulations.

The Coal and Other Mines (General Duties and Conduct) Regulations, 1956

"5 (1) Every person engaged at any working face (including a place in a road at which ripping or work of repair is in progress) or in setting or withdrawing supports shall make a careful examination of his working place at the beginning of each period of work and at appropriate times during the course of it, and in particular after any shot has been fired (at or near his working place) . . . and after any other interruption of work;

Provided that where several persons are working at a place together and one of them is in charge, it shall be sufficient for such examinations to be made by that person.

(2) Every person so engaged shall to the best of his power leave his working place at the end of his period of work in such condition as to allow work to be resumed there safely. If he is unable to do so, he shall . . . fence off the place and report the matter (immediately) to an official of the mine.

(3) Every person so engaged shall take any necessary steps to avoid interruption of the ventilation of the mine whether by accumulations of mineral, vehicles or stores.

"6 (1) No person shall interfere with any machinery . . . or operate any machinery required by or under the Act or by the manager of the mine to be operated in compliance with signals or which if not so required is capable of developing more than ten horse power except —

  (a) 
a mechanic or electrician of the mine;
  (b) 
a person carrying out duties in relation thereto in pursuance of an instruction in writing by the manager;
  (c) 
in emergency for the purpose of cutting off the supply of power.

(2) No person shall interfere with an electrical apparatus at a mine or operate any such apparatus which works at a voltage exceeding twenty-five except —

  (a) 
an electrician of the mine;
  (b) 
a person carrying out duties in relation thereto in pursuance of an instruction in writing by the manager;
  (c) 
in emergency for the purpose of cutting off the supply of power."

The Coal and Other Mines (Mechanics and Electricians) Regulations, 1956 — Pt. III

"8 (3) No person shall commence any work upon any cond uctor (or near an exposed conductor) . . . until an electrician of the mine has ensured that [the] conductor has been made dead and has taken any necessary steps by earthing or otherwise to ensure that it will remain dead until he is satisfied that it is safe to restore the current . . .

"9 (1) No person whose duties include the operation of any portable electrical apparatus supplied with electricity by means of a flexible trailing cable shall at any time either leave that apparatus while it is working, or leave the working place (except for the purpose of cutting off the supply of electricity to the cable) without ensuring that the cable has been made dead unless his instructions expressly authorise him to do so.

(2) A person whose duties include the operation during his shift of any electrical apparatus supplied with electricity by means of a flexible trailing cable shall ensure, before using that cable during that shift, that so much of it as is accessible is examined, and subsequently ensure that any further parts which become accessible are examined, and shall not use any cable which is thus found to be damaged or defective.

"10 (1) . . . a mechanic of the mine, in respect of mechanical apparatus, an electrician of the mine, in respect of electrical apparatus, or a person instructed (in writing by the manager) . . . shall stop forthwith the use of any such apparatus which it appears to him. . . may be in a dangerous condition by reason of some mechanical or electrical defect or abnormality, and cut off the supply of mechanical energy. . . or make dead the circuit or part of a circuit in which it is connected. . . and take any other necessary action to avoid danger. Unless in the case of a person instructed (in writing by the manager) his duties include the repair of the defect and he has repaired it, that apparatus shall not be used again . . . until a mechanic of the mine or an electrician of the mine (as the case may require) is satisfied that it is safe to do so.

(3) . . . a mechanic of the mine,. . . an electrician of the mine, . . . or a person instructed (in writing by the manager) shall report forthwith to an official of the mine anything which it appears to him . . . may affect the safe use of any (mechanical or electrical) apparatus, and which it is not part of his duties to prevent or remedy."

The Coal and Other Mines (Support) Regulations, 1956 — Pt. III

In Bars at Faces

"6 (1) At every working face . . . where machinery is used for cutting, conveying or loading mineral the system of support of the roof shall include the use of bars throughout the length of the face and over the whole width of the face working. Support rules in relation thereto shall require such bars to be so set that the interval between adjacent bars in the same row does not exceed four feet and that each such bar shall be supported at all times as effectively as practicable by at least two supports . . .

Bars at Roadheads

"7 (1) At every roadhead . . . the system of support of the roof shall include the use of rows of bars over the whole width thereof and throughout the following distance from the face in that roadhead or, where the road passes beyond a face to which it leads, from that face, that is to say —

  (a) 
in the case of a roadhead at an advancing face in which the roof is ripped within thirty feet outbye from the face, throughout the distance between the face and such ripping or, if there is more than one, such ripping farthest from the face; or
  (b) 
in the case of such a roadhead in which the roof is not so ripped, throughout the distance of thirty feet outbye from the face; or
  (c) 
in the case of a roadhead at a retreating face, throughout the width of the face working . . .

(4) Every such bar and (where used) crossbar shall be of adequate strength having regard to its length and span between points at which it is supported and shall be supported in such manner as to ensure its stability.

"8 (1) Support rules made with respect to every face working and roadhead. . . shall specify the intervals normally to be allowed and not to be exceeded between props, chocks or other supports set systematically, including the intervals between rows of . . . supports, between adjacent supports in the same row, and between the front row of supports and the face.

Holing Props and Sprags

"10 (1) During holing at any working face (including the face at any roadhead) holing props, sprags, or other suitable supports shall be set forthwith at such intervals not exceeding six feet as may be specified in the support rules . . . and such props, sprags or other supports shall not be removed until the mineral holed is about to be taken down.

Temporary Removal of Supports

"11 (1) Nothing in the foregoing Regulations shall prevent provision being made in support rules for the removal of —

  (a) 
any prop or other support, in so far as the maintenance thereof would prevent the operation of machinery used for cutting or loading, or the advancing or turning of any machine or the making of room for it;
  (b) 
any bar which cannot be maintained in the path of travel of an overcutting machine.

Any support or bar so removed shall be replaced forthwith after the passage of the machine.

(2) Where provision is made in pursuance of the last preceding paragraph for the removal of supports in order to advance or turn a machine or to make room for it, provision shall be made for the continued support of the roof which shall wherever practicable comprise the use of bars long enough to be effectively supported at all times by not less than two props or other supports.

(3) Nothing in the foregoing Regulations shall prevent provision being made in support rules for the postponement of the setting in any face working of any bar which would be in the intended path of travel of an overcutting machine and which would have to be removed to enable the machine to operate, but where such provision is made the rules shall provide for the setting of props or other supports instead of those bars and the maintenance thereof until it is necessary to remove them to permit the passage of the machine."

The Coal and Other Mines (Electricity) Regulations, 1956

Cutting off Electricity where In flammable Gas is found

"6 (1) Where any person finds that any place below ground . . . an amount of inflammable gas is present in the general body of the air at that place exceeding one and a quarter per cent by volume or sees an indication of gas at that place on the lowered flame of a safety-lamp, then . . . that person shall —

  (a) 
forthwith cause the supply of electricity to be cut off from all electrical apparatus at that place, other than any telephone or signalling apparatus or any electric safety-lamp, if the taking of those measures falls within the scope of his normal duties; or
  (b) 
if not, forthwith report the matter to an official of the mine or a person whose normal duties include the taking of those measures . . .

(3) After the supply of electricity has been cut off from electrical apparatus at that place in pursuance of sub-paragraph (a) of paragraph (1) . . . of this Regulation, no such supply shall be restored to that apparatus at that place until the senior official on duty at the mine, being satisfied that the amount of inflammable gas present in the general body of the air at that place does not exceed one and a quarter per cent by volume, so directs.

Protection of Apparatus

"10 Every person doing any work which may result in such damage to any electrical apparatus . . . that that apparatus might be a source of danger . . . shall take such steps to protect it from such damage as may be appropriate."

The Coal and Other Mines (Fire and Rescue) Regulation., 1956 — Pt. II

Fire Precautions and Equipment

"7 Where at any mine machinery for cutting or getting mineral is in use at a working face at which an ignition of gas has been, or having regard to the nature of the strata is liable to be, produced by such machinery, it shall be the duty of the manager to secure that —

  (a) 
the machine is provided with effective means to prevent such ignition; or
  (b) 
a portable fire extinguisher or supply of suitable dust or sand in a suitable container is carried on the machine; or
  (c) 
if owing to the height of the working it is impracticable to carry such an extinguisher or such a container on the machine, portable fire extinguishers or supplies of suitable dust or sand in suitable containers are provided at suitable intervals along the face and at any point at which an airway, which as regards that face is an intake airway, meets the face."