Chapter V

Regulations Regardinf the Roof Supports at the Coal Face

The system of supports which must be employed at the coal face is laid down in the Coal Mines Act and in Regulations which have been made under the Act. The Manager is required to post a notice near the entrance to the mine showing the system of supports that is to be employed at the colliery. The notice must show the following information:—

1. The distance between holing props or sprags.

This distance must not exceed 6 feet.

2. The distance between each row of props.

This distance between the rows must not be more than 4 feet unless bars are used, in which case the distance between the rows of props may be extended to 6 feet.

3. The distance between one prop and the next in the same row. This distance must not exceed 4 feet.

4. The distance between the nearest row of props to the face and temporary supports set nearer to the face.

This distance must not exceed 3 feet.

The Regulations also state how the supports shall be set:—

1. Every prop used as a support to the roof or side shall be set securely on a proper foundation, and if it becomes broken or loosened it shall be replaced or re-set as soon as practicable.

2. Every prop which is set as a roof support, unless it is set under a wooden bar or is set for the purpose of causing the roof to break, shall have a suitable wooden lid, big enough to cover the whole end of the prop, between the top of the prop and the roof or the bar.

3. Chocks which form part of the system of support shall be built on the natural floor and shall be set tightly between roof and floor. No round pieces of material shall be used in the building of a chock except where the chocks are left in the packs or waste.

4. The walls of every pack forming part of the system of support shall be well built on the natural floor. The pack must be filled with debris and rammed as tightly as possible to the roof over its whole area.

5. Bars shall be used to support the roof in all face workings where machinery is used for cutting, conveying or loading coal. Each bar must be supported by at least two supports.

6. The roof between the coal face and the ripping lip must be adequately supported over the whole width of the roadhead by rows of bars or of bars and cross bars, and the distance between the bars or cross bars shall not be more than 4 feet. Where there are any roof rippings within the roadhead a bar or bars shall be set as near as practicable to each ripping lip extending across the whole width of the lip.

7. Wherever the roof supports are removed in order to move or turn a machine or to make room for it, long bars shall be used to support the roof at that place and there shall never be less than two props under each bar.

The Coal Mines Act states that:—

1. Where roof supports have to be removed temporary supports shall in all cases be set to secure the safety of the persons employed.

2. Props shall not be withdrawn from the waste or from under any roof which appears to the Deputy to be insecure other than by means of a safety contrivance, e.g., a Sylvester.

According to the Regulations the Manager should also state the system of withdrawing the supports and the intervals between the supports which are to be set and maintained with a view to preventing the roof breaking down over the face working or in any other place than in the waste.