Museum
Museum
Friends of Durham Mining Museum
Events Calendar
Items for sale
Items for Sale
e-Books
Photograph Gallery
Document Archive
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious

Logo
E-Book Prev Page Return to Index Next Page E-Book
/ Act \

Summary of Main Recommendations and Conclusions

VENTILATION

General
1. 
The development plans for each colliery should incorporate full details of the ventilation arrangements to be adopted at each stage of development and the means to he adopted at each stage to achieve effective ventilation with a note of the date from which they will operate. The colliery officials should be fully conversant with these overall development plans for the ventilation of the colliery both as a whole and especially as it affects the particular part of the pit for which they may be responsible and their attention should be drawn without delay to any significant changes which are to be made from time to time in the plan. (Para. 7.)
2. 
All colliery officials who have a responsibility in connection with the ventilation should be familiar with the statutory ventilation plan of the mine. In particular, under-officials should be familiar with that part of the ventilation plan which applies to the section of the mine in which they work. All officials should be informed of projected changes in the ventilation system. The person responsible for the preparation of the statutory ventilation plan and for keeping it up to date should also be notified promptly of all such changes. (Para. 8.)
3. 
A coal face should not have two adjacent gate roads which are both either intake or return airways unless steps are taken to maintain effective ventilation in both airways and along the length of face between them. (Para. 10.)
4. 
Local management, when confronted with difficult ventilation problems, should take advantage of the expert advice which should always be available to them within the National Coal Board. (Para. 11.)
5. 
Before the ventilation systems of two or more collieries are interconnected a ventilation engineer should always be consulted. (Para. 11.)

Gas Emission
6. 
Even though the results of determinations of firedamp content in the general body of the air show that the gas emission is very low and/or well diluted, there should be no reduction in the frequency of, or care in, testing for gas at places outside the main airstream such as ripping lips, the roof of roads, the waste edge and fast ends. Especially is this true if analysis shows any increase in the gas content of successive samples taken from the general body of the air in a return airway, since such an increase can have an effect locally much greater than the size of the increase would seem to indicate. (Para. 15.)
7. 
A sufficient margin of ventilation should be maintained to provide for the normal contingencies of mining such as emissions due to a waste fall or drop in barometer. (Para. 16.)
8. 
Precautions such as firedamp drainage, improvement in control of the strata in the district as a whole and in the support of the roof in the face workings, including strengthening of the waste edge supports, and ample ventilation can, either individually or in combination, make a valuable contribution towards minimizing the danger of gas emission from the waste. (Para. 17.)
9. 
Adequate means such as "bleeder" or gas drainage systems should he provided for removing gas which may collect in the wastes of retreating longwall faces. (Para. 18.)
10. 
Care should be exercised to avoid excessive air leakage anywhere and especially through wastes during pillar extraction and through pillared areas. (Para. 18.)
11. 
In the ventilation of localized vulnerable points it may not be necessary to use mechanical means of ventilation such as an auxiliary fan. Consideration should always be given to diverting part of the normal ventilation airstream, e.g., by means of a brattice or some other suitable airduct. (Para. 19.)

Supervision of Ventilation Systems and Equipment
12. 
Ventilating systems and all the equipment and arrangements which they incorporate should be kept under close review to ensure (i) that they are actually achieving what they are intended to achieve, and (ii) to ensure that any alterations found necessary in the light of changing circumstances are made effectively and promptly. (Para. 20.)
13. 
Apart from observance of the statutory requirements relating to the installation of booster fans, the colliery manager will he well advised to consult a ventilation engineer when a system of auxiliary fan ventilation is being established. (Para. 21.)
14. 
The wider application of reversible ventilation for headings and drifts in coal mines warrants further investigation. (Para. 22.)

Inspection for Gas
15. 
Deputies and overmen must be given a clear understanding of the parts of the mine for which they are responsible. In particular, as new roads are started and old ones finished, Deputies should be informed in good time by a superior official of any changes in the arrangements for their inspection. (Para. 23.)
16. 
Extra care is called for in testing for gas along the waste edge of a new developing face. (Para. 24.)
17. 
The Deputy must record a full account in his statutory report of any unusual incidents reflecting on the efficiency of the ventilation system, e.g., the percentages and location of any gas encountered or the stoppage of any auxiliary fan. (Para. 24.)

Gas Detectors
18. 
Investigations into the various methods and types of equipment which could be used by Deputies for testing for gas at places where tests should be made but are normally difficult of access, and especially gas in a thin layer next to the roof in a high roadway, should be pursued energetically as a priority project. (Paras. 26 and 31.)
19. 
Until such time as better methods of testing for gas in places where tests should be made, but are normally difficult of access, are developed, the main instrument for routine gas testing by the Deputy must remain the flame safety lamp which, if raised with a fairly full flame, can give a satisfactory indication of the presence or otherwise of gas in high places by the flicker and colour of the flame. (Para. 29.)
20. 
Improved rods or sticks and methods of connection between the lamp and the stick should be devised to assist in the testing for gas at high places. Consideration should also be given to the production of flame safety lamps with flat tops and top air feed only. (Para. 30.)
21. 
The emphasis in safety lamp development should be on the use of the equipment as a means of gas detection rather than as a means of illumination. (Para. 32.)
22. 
The development of methods of relighting flame safety lamps alternative to the pyrophor bar should be pursued. Now that the battery relighter is available, there is scope for a considerable reduction in the size and weight of such lamps. (Para. 33.)
23. 
Automatic gas detectors are of value in checking ventilation conditions on the face and they also have a useful application at special points of potential gas risk, e.g., the highest points on roadways. We would welcome further work in their development. (Para. 34.)
24. 
A strong campaign should he initiated down to colliery level through the consultative machinery and in conjunction with the local union officials to obtain the co-operation of the workmen in carrying and using firedamp detectors. (Para. 35.)
25. 
In making underground visits officials of the mine should always carry a flame safety lamp or alternative instrument. (Para. 36.)

Gas Dispersal
26. 
The Safety in Mines Research Establishment should give priority to the research which they are conducting into means of tackling the gas layering problem. (Para. 39.)
27. 
Apart from good general ventilation, the best practical local means at present available for preventing or dispersing accumulations of gas at the roof of roadways is the use of brattices at the key points where gas may be expected to accumulate. Brattices may also have an important application in certain circumstances at the face to maintain good ventilation conditions, e.g., in fast ends or possibly at the waste edge. (Paras. 39 and 40.)
28. 
For the purpose of preventing or dispersing roof layers of firedamp in headings and drifts, trials should he carried out of the use of small individual branch pipes from the main ventilation duct to blow air into or exhaust gas from places where gas is likely to accumulate. (Para. 41.)
29. 
An exceptionally large cavity in the roof of a roadway calls for special treatment both for the detection of gas and dispersal of any gas that may be found. The use is recommended either of a small auxiliary fan to blow air into the cavity or of small drainage pipes to exhaust the gas into a return airway. (Para. 42.)
30. 
Colliery officials should be aware of the ability of gas in certain circumstances to act as a plug in a roadway, thus impeding the ventilation current. (Para. 43.)

STRATA CONTROL

31. 
Special steps should be taken to limit the effects of first roof weighting. In certain circumstances it would seem advantageous to build packs for some distance after a new face moves off before adopting full caving. (Para. 46.)
32. 
Roadway cavities should be dealt with rapidly and effectively with a view to preventing their extension. (Para. 47.)
33. 
Where packing is done, regular and systematic advancement of the packs along the whole length of the face is important and individual packs should not he allowed to fall behind the general face line. It is essential that these packs should be built of proper material. (Para. 48.)
34. 
The workmen engaged in the setting of supports should appreciate the importance of avoiding practices likely to create cavities or unintentional voids which give rise to difficulties in ventilation and where gas may collect. To this end it is essential that supports should be both set and later withdrawn strictly in compliance with the instructions given by the colliery management. (Para. 49.)

CARE AND MAINTENANCE OF EQUIPMENT

Electrical Apparatus
35. 
In the design and manufacture of electrical apparatus and choice of its site, regard should be paid to the risk of falls of ground and of the occurrence of inflammable gas. All electrical apparatus which, if damaged, is capable of producing incendive sparking should have substantial protection. and effective support of the roof and sides should be provided at all times to safeguard against falls of ground in the immediate vicinity of the apparatus. (Para. 51.)
36. 
Makeshift arrangements for the protection of electric cables in places where shots are to be fired are unsatisfactory. Protection should be achieved by the systematic use of a sufficient length of strong protective material and whatever method is adopted should be carefully chosen to suit the particular circumstances. (Para. 52.)
37. 
The mechanical strength of paper-insulated cables and their suitability for underground use should be further examined jointly by the National Coal Board, H.M. Electrical Inspectors and the manufacturers. (Para. 53.)
38. 
In view of the prohibition of the jointing of shotfiring cables for use with large capacity exploders, the shotfirer or his assistant should examine the cable visually for damage every time it is used to ensure that any defective portion is cut off or the cable replaced. (Para. 54.)
39. 
Efforts to find and introduce a safer type of large capacity exploder, including the modification of the Beethoven exploder to reduce the risk associated with its use in its present form, should be urgently pursued. (Para. 55.)
40. 
Switchgear calls for specially high standards of supervision and maintenance because it contains the apparatus both for earth leakage and for overload protection. (Para. 56.)
41. 
All electricians should constantly bear in mind the need to maintain the high standards which their duties demand. (Para. 57.)
42. 
Electricians should always bear in mind their statutory obligation to isolate electrical apparatus before carrying out work on it. The electrical industry should he encouraged to develop easier methods than are now available for tracing electrical faults when the power has been cut off. (Paras. 57 and 58.)

General
43. 
All employed underground should exercise common sense and reasonable care in the treatment of underground equipment, and have a responsible awareness of the potential consequences of its abuse. (Para. 60.)

OTHER MINING FACTORS

Coal Dust Explosions
44. 
A working party of experts on coal dust should he established to consider all the available evidence including the results both of British and Polish research and to submit a report, with recommendations, on their investigations. (Para. 66.)
45. 
Managers should continue at all times in compliance with the present Regulations to ensure (i) a high standard of cleanliness in respect of dust accumulations on roadways, (ii) stone dusting at frequent intervals on the "little and often" principle and (iii) the proper installation of stone dust barriers in accordance with the N.C.B. directive. (Para. 67.)
46. 
The need at all times for high standards in the cleaning up of accumulated coal dust and in stone dusting should be recognized by all persons concerned. (Para. 68.)

Shotfiring
47. 
All concerned must be seized of the need for scrupulous compliance with the requirements of the Explosives Regulations. (Para. 69.)
48. 
The jettisoning or concealment of unused explosives underground instead of returning them to store at the end of the shift cannot be too strongly condemned. Everyone concerned should co-operate in making effective the official systems for the control of explosives issued, consumed and returned to store. (Para. 69.)

Contraband
49. 
All the interests concerned should co-operate in the implementation of the measures recommended by the Sub-Committee for preventing smoking underground in safety lamp mines. (Para. 70.)

Naked Light Mines
50. 
We recommend that the industry should work towards the progressive elimination of naked lights in mines, subject to appropriate relief from certain of the consequential requirements of the Act and Regulations when safety lamps are introduced. (Para. 76.)

HUMAN FACTORS

51. 
The moral approach to the problems of safety in mines should be given greater emphasis in all education and training courses and particularly in the preliminary training courses for all new entrants to the industry. The special responsibility for standards of underground safety carried by under-officials, in particular the Deputy, must he given due weight in their training. (Paras. 79-84.)
52. 
Greater efforts should be made, through the consultative machinery, to develop and encourage the growth of the personal feeling of responsibility for safety by the individual. (Para. 85.)
53. 
Special steps should he taken with the active co-operation of all the constituent bodies represented in the consultative machinery for the full and frank consideration of the lessons emerging from this report both within their own organizations and throughout the consultative machinery, particularly at Colliery Consultative Committees. Special meetings should be convened to bring these lessons home to the body of the Board's employees who do not participate directly in the activities of the consultative machinery. The co-operation of H.M. Inspectors should be sought in all these discussions. We suggest that the report should also he considered by the Institution of Mining Engineers and the Association of Mining Electrical and Mechanical Engineers. Publicity for the lessons emerging from the report should be arranged through special articles in Coal magazine and the technical press, and films suitable for showing in colliery canteens or welfare institutes should be made on appropriate aspects of our investigation. (Para. 86.)

 

Prev Page Return to Top of Page Next Page
mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 31 Dec 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print