Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
Items for sale
Items for Sale
e-Books
Photograph Gallery
Document Archive
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious

E-Book Prev Page Return to Index Next Page E-Book
Explosions in Coal Mines
/   \

Conditions In Mines Leading To Explosions.

Some general conditions concerning explosions in coal mines will be considered.

The initiation of an explosion may be due to an ignition of fire-damp, to the ignition of a cloud of coal dust, or to the ignition of a mixture of fire-damp and coal dust. The flame causing ignition may be that of an open light used for lighting, or of a fire for producing ventilation or steam, or of a fire accidentally caused; or it may be from gunpowder or other explosive, or from a safety lamp.

Fire-damp. — Fire-damp, owing to its lightness, rises to the highest points, and until diffusion takes place, is found in such places; otherwise it behaves as air, and passes along mixed with the ventilating current. A naked light is a common source of its ignition.

Fires underground, whether used for producing ventilation or steam, are placed in such positions and under such conditions, as to render it improbable that fire-damp, in such quantity as to be inflammable, can reach them. Fires accidentally caused in mines producing fire-damp may cause explosions. Second explosions, which sometimes occur, are probably initiated in this way. Flame of gunpowder, or other explosive, is probably a rare cause of the ignition of fire-damp present in the air current (in the absence of dust). Before shots are lighted in fiery mines an examination is made for gas, and men know they would risk their lives if they fired a shot where gas could be detected in the air current. It is very improbable that in the interval between the examination and the explosion of the shot, the air passing over it would become inflammable, from gas alone. Gas liberated by a shot, or issuing in a jet near it, is not infrequently ignited by the flame, and burns at the point of issue. A shot fired near a goaf where a proper examination cannot be made, or near a cavity in the roof which has not been examined, may occasionally ignite an accumulation of fire-damp. When a shot is blown out, the probability of it igniting gas is increased, by reason of the increased distance to which the flame is carried; and when coal dust has been used in the stemming of a blown out shot, the flame extends still further, and so increases the possibility of igniting gas.

The flame of a safety lamp may cause ignition of fire-damp outside it from any one of four causes: (a) If the lamp is defective. A defective or injured lamp of any construction may be no safer than an open light. (b) In the case of many of the safety lamps now in use, such as the Davy and Clanny lamps, if they are exposed in an explosive mixture of fire-damp and air travelling above a certain velocity. It has been proved by repeated experiments that such lamps will ignite gas outside them, when exposed in an explosive current travelling at from 6 to 10 feet per second. (e) Some lamps of large internal capacity, or those so enclosed by solid casing as to increase the effect of internal explosion on the gauze, when manipulated in a particular manner, in a stationary mixture of fire-damp and air, will cause the ignition of gas outside them by the explosion of gas within them. This fact was only recently discovered by M. J. B. Marsaut, a French mining engineer, who describes the process by which it can be effected.07 (d) It is possible for some lamps to pass flame to gas outside them, if they are subject to a momentary wave or gust of air such as may be caused by the firing of a shot,08 or by attempting to blow out the flame,09 while they are surrounded by an inflammable or explosive mixture of fire-damp and air, In the cases (b), (c), and (d) it is not the flame of the safety lamp which directly ignites gas outside the gauze; the flame of the lamp first ignites gas inside the gauze, then usually going out; the ignited gas inside the gauze eventually communicates with the outside gas.

It may be pointed out that some of the tests to which safety lamps are submitted in experiments are much more severe than any which they are likely to encounter in practice. The writers believe that many explosions attributed to the ignition of fire-damp by the flame of safety lamps have been due to other causes.

Coal dust. — Coal dust, under ordinary circumstances, does not exist as a dense cloud in the air of a mine, and is not carried along by the ventilating current, except to a very limited extent. To become inflammable in the air the coal dust must be present in the form of a dense cloud.

An open light is a rare source of ignition of a dust cloud. Examples of this are stated to have occurred in some mines in France,10 where the circumstances were favourable to the production of a dense cloud of coal dust above an open light. Accidents caused by the ignition of a cloud of coal dust by open lights on the surface are recorded, both in this country and on the Continent.

Fires underground, used for producing ventilation or steam, are so situated that it is very improbable that they should cause the ignition of coal dust in the air. It appears possible that under favourable conditions a fire accidentally caused might do so. If the conditions were such that the fire caused a current of air, so strong as to carry a cloud of coal dust over it, or if the fire caused a fall of stone or timber so as to produce a dust cloud of sufficient density, the dust might be ignited.

The disturbance produced by the explosion of gunpowder ensures, under some conditions, the production of a dust cloud, and the accompanying flame is a common source of its ignition.

There appears no reason to suppose it possible that a dust cloud may be ignited by the flame of a safety lamp.

Coal dust, not suspended in the air, is sometimes ignited by the flame of a shot, or by an open light. This class of ignition may be compared with that of fire-damp, burning, as a jet, at the point of issue.

Fire-damp and coal dust. — It has been shown experimentally that a cloud of coal dust in air, containing, according to Galloway,11 less than 1 per cent., and according to Abel,12 from 2 to 2½ per cent, of fire-damp, is readily inflamed at ordinary temperatures and pressures, by an open light.

The presence of a porous dust, even of a non-inflammable nature, will determine the ignition of fire-damp and air mixtures, which are not inflammable in the absence of the dust.

The flame of gunpowder, passing into a cloud of coal dust, in air containing a small proportion of fire-damp, will be more likely to cause ignition than in the absence of fire-damp.

There appear, at present, no grounds for stating that the presence of coal dust, in air containing fire-damp, adds to the probability of the flame of a safety lamp igniting the mixture.

The extension of an explosion, however initiated, may be caused by the continued ignition of fire-damp, coal dust, or a mixture of the two. It frequently happens that a gas explosion is confined, owing to the absence of dust, to a gas and air mixture. It cannot be so positively asserted that an explosion is entirely confined to dust, because the practical absence of gas, although it may be probable, cannot be positively proved by an examination after the explosion, as can the absence of dust in some fire-damp explosions.

It has been stated that an inflammation of coal dust may cause a considerable explosion by bringing about the ignition of fire-damp and air mixtures. This is possible, but it appears to the writers that the greatest danger is the converse of this, that the explosion of an accumulation of fire-damp may cause ignition of dust. In all the explosions which have been described, except Whitehaven, they were confined to those parts of the pits where there was a plentiful supply of coal dust, and, in all cases, passed from one part of the pits to others, along roads on which there was the least probability of fire-damp being present in the air. So far as can be gathered, from accounts of other large explosions, the same holds good.

Fire-damp issues from the strata in mines, either normally as a regular flow, or abnormally as a sudden outburst. It exists either mixed with the air current and passing along with it, or as an accumulation, more or less pure, in cavities in the roof, in the open parts of goaves, or in abandoned and unventilated passages.

Fire-damp existing as an accumulation, sometimes flows into the air current with more or less suddenness, as when a fall of roof-stone takes place near it, which may cause a rapid displacement of fire-damp, followed by an equally rapid return. When pent up by water, and under pressure, fire-damp sometimes comes off in gluts, a phenomenon known in mining as a water blast."

A lessened atmospheric pressure causes fire-damp, existing as accumulations in unventilated places or goaves, to flow into previously uncontaminated parts; it also increases the flow of fire-damp issuing from gullets and fissures in the strata. At some collieries, where large areas of abandoned workings and goaves are adjacent to the return air ways, it is found that, during a rapid fall of pressure, fire-damp issues from them in such quantity, as to show on the flame of a safety lamp in the air in some of the returns. It has not been proved, and it is not probable, that the normal flow of fire-damp from solid strata is influenced to an appreciable extent by natural variations of atmospheric pressure.

Sudden outbursts of fire-damp from the strata are rarely met with, so far as the writers can learn, except while mining new ground. Fire-damp issuing as a sudden outburst will probably displace the air in the vicinity of the outburst. It will always have a tendency to pass from the point of issue with the air current, rather than against it. The extent to which it may back against the current will depend upon circumstances, such as the amount of gas given off, compared with the amount and velocity of the air currents, and the rise or dip of the passages in the vicinity.

A study of the phenomena accompanying the issue of large outbursts of gas shows that13 — (a) After the outburst evidence can almost always be found as to the point of issue. (b) During the issue workmen near are alarmed, and retreat with their lamps. (c) In many cases the lamps are extinguished by the gas, and sometimes workmen are suffocated.

The results of the ignition of what were stated to be large outbursts of gas, in the probable absence of coal dust, do not resemble the results described in the five Durham explosions.

The issue of fire-damp, either from the strata or from open parts of the mine, is most likely to take place at or near the working face or in the return air ways ; and, from the place where it issues, it is most likely to exist in the air passing towards or along the return air ways. It is in the return air ways, therefore, that there is the greatest probability of an explosion of fire-damp on a large scale. The fact that such explosions are not experienced renders it improbable that fire-damp plays the principal role in coal mine explosions.

Mixtures of fire-damp and air are only explosive, at ordinary temperatures and pressures, within certain comparatively narrow limits, which have not yet been accurately determined. It appears probable that all mixtures, between those containing per cent, and 20 per cent, by volume of fire-damp, are inflammable. A mixture containing about 10 per cent. by volume of fire-damp is the most explosive. The compression and consequent heating of mixtures of fire-damp and air (not inflammable at ordinary temperatures and pressures), by an explosion, will render them inflammable. A large volume of pure fire-damp existing in a mine is not available for the transmission of flame ; it requires first to be mixed with air.


07 See "Miners' Safety Lamps," Vol. IX., Midland Institute of Mining, Civil, and Mechanical Engineers. Translation of J. B. Marsaut's paper by T. Carrington.
08 See "Safety Lamps and Shot Firing," by W. Galloway, North of England Institute of Mining and Mechanical Engineers, Vol. XXIV.; also Proceedings of the Royal Society, 1874.
09 See letter by W. Galloway. "Colliery Guardian," 27th August, 1886.
10 See paper "On the Influence of Coal Dust in Explosions of Fire-damp," by M.M. Chauselle and Desbief, published in "Bulletin de la Societe de l'Industrie Minerale de Sainte-Etienne. 1875." Translation by W. Galloway, published in "Iron," January 26th to March 23rd, 1878.
11 Transactions of Royal Society, XXIV.
12 Report on the Results of Experiments made with Samples of Dust Collected at Seaham Colliery," by F. A. Abel, C.B., F.R.S.
13 See "On Instantaneous Outbursts of Inflammable Gas in the Coal Mines of the Belgian Basin," by A. G. Arnould, Royal Chief Engineer of Mines at Mons. Translation in Vol. IX. of the Transactions of the Midland Institute of Mining, Civil, and Mechanical Engineers, by T. Mitchell; also "Narrative of Sudden Outbursts of Gas in Collieries Working the Barnsley Thick Coal and the Silkstone Coal in the neighbour. hood of Barnsley," published by the Midland Institute.

 

Prev Page Return to Top of Page Next Page

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 31 Dec 2022