Museum
Museum
Friends of Durham Mining Museum
Events Calendar
Items for sale
Items for Sale
e-Books
Photograph Gallery
Document Archive
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious

Logo
E-Book Prev Page Return to Index Next Page E-Book
/ \
Travelling Roads and Haulage.

42. — (1) For every seam in a mine newly opened after the commencement of this Act and not being a mine exempted from this provision by general regulations under this Act, there shall be provided (except within such distance from the shaft as may be fixed by the regulations of the mine) two main intake airways, which shall be of such size and shall be maintained in such condition as to afford a ready means of ingress to and egress from the workings, and one of which shall not be used for the haulage of coal.

General regulations shall be made under this Act for determining the classes of mines which ought, having regard to their natural condition, to be exempted from the foregoing provision, and those regulations shall also provide for the exemption of any mine in which the number of persons employed underground does not at any one time exceed one hundred or which is naturally wet throughout.

(2) For every seam in a mine newly opened after the commencement of this Act which is exempted by general regulations from the foregoing provisions of this section, and for every seam in a mine opened before the passing of this Act, there shall be provided two main airways, which shall be of such size and shall be maintained in such condition as to afford a ready means of ingress to and egress from the workings.

(3) In the case of every mine or seam newly opened after the commencement of this Act, all stoppings between main intake airways and main return airways and all air-crossings shall so far as practicable be so constructed as not to be liable to be destroyed in the event of an explosion, and general regulations may be made under this Act providing for the manner in which such stoppings and air crossings are to be constructed.

(4) Where, in the case of any mine or seam newly opened after the passing of this Act, the air-current in the main return airway is found normally to contain more than one half per cent. of inflammable gas, that airway shall not (except for the purpose of removing any coal gotten in the operation of enlarging or repairing the airway, or within a distance of three hundred yards from the shaft) be used for the haulage of coal.

For the purpose of this provision, the average percentage of inflammable gas found in six samples of air taken by an inspector in the air-current at intervals of not less than a fortnight shall be deemed to be the percentage normally contained in the air-current.

(5) In the case of every mine newly opened after the commencement of this Act, the main airways, if driven in the same seam, shall be so arranged that they shall not, at any point, except for the purpose of crossing or within a distance of three hundred yards from the shafts, or such other distance from the shafts as may be fixed by the regulations of the mine, be less than such distances apart as shall be fixed by the regulations of the mine, and the distances from one another of the connexions between the main airways shall not be less than the minimum distance specified in those regulations.

43. — (1) On and after the first day of January, nineteen hundred and fourteen, no person, other than an official of the mine or a person employed on the road in connexion with the haulage, or a person engaged in carrying out any repairing work requiring to be carried out forthwith, shall, while the haulage is in motion, travel on foot on any haulage road on which the haulage is worked by gravity or mechanical power, except —

 (a) 
Where there is provided on one side of the road a clear space of at least two feet in width between the tubs and that side of the road, and the rate of haulage is not more than ten miles an hour; or
 (b) 
Where, in the case of a haulage road in which such a clear space as aforesaid is not provided, the rate of haulage is not more than three miles an hour and the gradient does not exceed one in twelve, or in respect of any part of the road not exceeding one hundred yards in length, one in nine, and the space between the tracks of rail, where there is more than one track, is kept clear of obstructions:
  
Provided that —
  
 (i) 
in the case of a haulage road in which such a clear space as aforesaid has been provided, but the space so provided has in some part of it been reduced to a width of less than two feet by reason of some cause over which the owner, agent, or manager of the mine has no control, the foregoing prohibition shall not apply during the time (not exceeding the time reasonably required for the purpose) during which the repairs necessary for restoring the width to two feet are being carried out; and
 (ii) 
the exception herein-before contained as respects haulage roads in which no such clear space as aforesaid is provided shall apply only in the case of mines opened before the commencement of this Act or mines in which the character of the strata makes it unreasonable to require such a clear space to be provided.
  
If any question arises as to whether the character of the strata in any mine makes it unreasonable to require a clear space to be provided, that question shall be determined in the manner provided by this Act for settling disputes.

(2) Where the haulage is worked by gravity or mechanical power, no person shall be allowed to ride on sets or trains of tubs except —

 (a) 
a person travelling on a set or train for the purpose of detaching or attaching tubs from or to the haulage rope, if that set or train is not proceeding at a higher speed than three miles an hour; or
 (b) 
men being conveyed, with the written permission of the manager or under-manager, to or from their work at the commencement or end of their employment (including any person in charge of a set or train of tubs on which men are being so conveyed); or
 (c) 
the driver of a locomotive.

(3) In all places where sets or trains consisting of three or more tubs are coupled or uncoupled, there shall be a clear space of at least two feet between tubs standing on any rails and the side of the road nearest to those rails:

Provided that —

 (a) 
where there are two parallel lines of rails, the foregoing provision shall not apply if there is a clear space of at least three feet between tubs standing on those rails; and
 (b) 
where, in the case of any existing mine, compliance with the requirements of this subsection would necessitate the removal of arching or other masonry work, or where, in the case of any mine, sets or trains of tubs are coupled or uncoupled at the face, or at the pass-bye next the face, other provisions for securing safety may be substituted by the regulations of the mine for those requirements.

The provisions of this subsection shall come into operation on the first day of January, nineteen hundred and thirteen:

Provided that this subsection shall not apply to any district in any mine as respects which the Secretary of State is satisfied that it will be worked out within three years from the commencement of this Act.

(4) In measuring any clear space for the purposes of this section, any props or other supports of the roof projecting beyond the side of the road shall be deemed to form part of the side.

44. — (1) Every haulage road on which the haulage is worked by gravity or mechanical power, shall be provided with sufficient refuge holes at intervals of not more than ten yards, but, if the gradient does not exceed one in twenty, and either such a clear space as aforesaid is provided or the rate of haulage is not more than three miles an hour, it shall be sufficient if the intervals are not more than twenty yards.

(2) Every haulage road on which the haulage is worked by animal power shall be provided with sufficient refuge holes at intervals of not more than twenty-five yards.

(3) Every refuge hole shall be —

 (a) 
as near as may be three feet in width and not less than four feet in depth;
 (b) 
not less in height than the height of the haulage road at the point where the hole is, or six feet, whichever is the less;
 (c) 
if such a clear space as aforesaid is provided, on the same side of the road as that space;
 (d) 
if no such clear space as aforesaid is provided, on the same side of the road as the other refuge holes, or where the road is on a curve, on the outer side of the curve;
 (e) 
marked with a distinctive number;
 (f) 
if necessary to make it readily visible, constantly kept whitewashed both inside and for a distance of not less than one foot round the aperture;
 (g) 
kept clean.

(4) Nothing shall be placed in any refuge hole or across the entrance thereto so as to impede ingress.

(5) Notwithstanding anything in this section, it shall not be necessary to provide refuge holes on any road within twenty-five yards of the working face.

45. — (1) Every travelling road shall be of adequate height, and, if the height of any such road appears to the inspector of the division to be inadequate, he may require that the height be increased to such extent as he thinks proper, and the manager shall comply with the requisition unless he disputes the reasonableness thereof, in which case the dispute shall be settled in manner provided by this Act for settling disputes.

(2) Every road on which a horse or other animal is used underground or by which it has to pass to get to its work shall be of sufficient dimensions to allow the horse or other animal to pass without rubbing itself or its harness against the roof or sides or the bars or props supporting the roof or sides.

46. — (1) Every rope used for haulage which is capped shall be recapped at intervals of not more than six months in accordance with general regulations under this Act.

(2) Sufficient and suitable sprags, lockers, or drags shall be provided and used for the purpose of holding a tub or set of tubs —

 (a) 
at the top of every incline on which the haulage is worked by gravity;
 (b) 
at every place where sets or trains consisting of three or more tubs are coupled or uncoupled;
 (c) 
on all roads or parts of roads where the gradient exceeds one in twenty, and the haulage is worked by animal power.

(3) Stop blocks or other similar contrivances shall be provided at the top of every incline on which the haulage, not being endless-rope or endless-chain haulage, is worked by gravity, and at every entrance thereto by which tubs are brought on to the incline.

(4) On every haulage road where mechanical haulage, not being endless-rope or endless-chain haulage, is used, and where the gradient exceeds one in twelve —

 (a) 
runaway switches or other suitable contrivances shall be provided where the use thereof is practicable to prevent accidents in the event of a tub running away;
 (b) 
there shall be provided and attached to an ascending tub or set of tubs a back-stay or other suitable contrivance for preventing the tub running back;
 (c) 
over-chains, bridle-chains, or other suitable appliances shall be provided to prevent tubs in which persons are being conveyed from becoming disconnected and running away.

47. Every haulage road shall be kept clear as far as possible of pieces of coal and other obstructions.

48. Every haulage road on which persons travel and on which the haulage is worked by gravity or mechanical power shall be provided (if exceeding thirty yards in length) with some proper means of communicating distinct and definite signals between all regular stopping places and the ends of the road.

Support of Roof and Sides.

49. The roof and sides of every travelling road and working place shall be made secure, and a person shall not, unless appointed for the purpose of exploring or repairing, travel on or work in any travelling road or working place which is not so made secure.

50. — (1) Where props or props and bars or chocks are used to support the roof at the working face, the roof under which any work of getting coal or filling tubs is carried on shall be systematically and adequately supported, and the props or chocks shall be set at such regular intervals and in such manner as may be specified in the notice herein-after mentioned.

(2) Holing props or sprags shall be set as soon as practicable, and shall be set at such regular intervals and in such manner as may be specified in the notice hereinafter mentioned, and shall not be removed until the coal is about to be taken down and before the roof supports (if any) have been advanced in the manner specified in the notice.

(3) In all parts of a roadway in which sets or trains consisting of three or more tubs are coupled or uncoupled, the roof and sides shall be systematically and adequately supported, and in such parts and in all other parts of the roadway the roof or sides of which require to be supported, if props or bars are used as supports, such supports shall be set at such regular intervals and in such manner as may be specified in the notice herein-after mentioned.

(4) The manager shall, by notice, specify the manner in which the supports are to be set and advanced, and the maximum intervals to be observed on roadways between the supports, and at the face —

 (a) 
between each row of props;
 (b) 
between adjacent props in the same row;
 (c) 
between the front row of props and the face;
 (d) 
between the holing props or sprags;
 (e) 
between chocks:

Provided that the interval between holing props or sprags shall in no case exceed six feet.

(5) If the inspector of the division considers that the system of supporting the roof and sides adopted in any part of a mine is unsatisfactory, either by reason of the distances fixed or any of them being excessive or otherwise, he may require the manager to fix some less distance or otherwise modify the system, and the manager shall comply with the requisition unless he disputes the reasonableness thereof, in which case the dispute shall be settled in manner provided by this Act for settling disputes.

(6) This section shall not apply to the mines of stratified ironstone in the Cleveland district or of thick coal in the South Staffordshire district or to mines in any other district as respects which the Secretary of State is satisfied that similar conditions prevail.

(7) Nothing in this section shall prevent a workman from setting supports in his working place at more frequent intervals than those specified in the notice aforesaid, where necessary for safety.

51. Where the work of erecting the supports of the roof and sides of working places is done by the workmen employed therein, a sufficient supply of timber or other materials suitable for supports shall be kept at or within ten yards of every working place where, in pursuance of this Act, supports are required to be erected, and also at the pass-bye, siding or other similar place in the mine convenient to the workmen; and it shall be the duty of the firemen, examiners, or deputies to see that such sufficient supply is so kept, and any working place in which such a sufficient supply is not kept shall not be deemed to be safe for the purpose of the provisions of this Act. Sufficient timber or other materials as aforesaid, to enable the firemen, examiners, or deputies to see that the provisions of this section are complied with shall be constantly provided.

52. — (1) In any part of a mine where any work is being carried out which necessitates the removal of roof supports, temporary supports shall, in all cases, be set so as to secure the safety of the persons employed.

(2) Props shall not be withdrawn from the waste or goaf or from under a roof which appears to a fireman, examiner, or deputy to be insecure otherwise than by means of a safety contrivance, and it shall be the duty of the firemen, examiners, and deputies to examine all roofs from under which props are about to be withdrawn with a view to the determining whether the props ought to be withdrawn by means of a safety contrivance.

 

Prev Page Return to Top of Page Next Page
mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 31 Dec 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print