| | (1) |
There should be amendments to the following statutory provisions:
|
| | |
| | (a) |
The Mines and Quarries Act 1954: Section 10 The person appointed to read reports on behalf of the manager should be the holder of a first or second class certificate of competency.
|
| | (b) |
The Coal and Other Mines (Managers and Officials) Regulations 1956:
|
| | |
| | (i) |
The provisions of Regulation 6A relating to the appointment of a competent person to read reports on behalf of an undermanager should be revoked.
|
| | (ii) |
A statutory shift report should be introduced for officials superior to deputies but subordinate to undermanagers.
|
|
| | (c) |
The Coal and Other Mines (Surveyors and Plans) Regulations 1956
|
| | |
The manager should ensure that any information that is necessary to be supplied to the surveyor for recording on the plans and sections which are required to be kept at the mine is accurate and should certify this by counter-signing all such plans and sections prepared by or under the supervision of the appointed surveyor for the mine.
|
| | (d) |
The Coal Mines (Precautions Against Inflammable Dust) Regulations 1956
|
| | |
Regulation 10A should be amended to include the recording on a plan the position of all the stone dust barriers specified in the manager's scheme by virtue of this Regulation.
|
| | (e) |
The Coal and Other Mines (Ventilation) Regulations 1956
|
| | |
These Regulations should be amended to include the following provisions:
|
| | |
| | (i) |
Rules should be made for the installation and operation of auxiliary fans.
|
| | (ii) |
Narrow drivages which require at any time to be ventilated by auxiliary means are, thereafter, constantly ventilated by positive means.
|
| | (iii) |
The manager should specify the construction of any fence erected to prevent access to an unventilated part of a mine and should ensure that it is maintained constantly in an effective condition.
|
|
| | (f) |
The Coal and Other Mines (Fire and Rescue) Regulations 1956:
|
| | |
| | (i) |
Regulation 27 should prescribe standards for the size, equipment and facilities of rescue rooms. The room should be maintained solely for rescue work.
|
| | (ii) |
Regulations should be made to cover the approval, carrying and training in the use of self-rescuers.
|
|
|
| | (2) |
The National Coal Board should implement as they arise any interim findings of the National Committee referred to in para 124.
|
| | (3) |
The National Coal Board Committee studying the design of self rescuers should be reconvened as soon as possible. The membership and terms of reference should be reviewed.
|
| | (4) |
The National Coal Board should ensure that wherever possible its specifications for auxiliary and booster fans are completed during the time this new equipment is in the prototype stage. Such prototype equipment should be used only in closely controlled conditions. The test and assessment requirements for new equipment of this type should include standards of construction, performance and ease of maintenance underground.
|
| | (5) |
When a plan for the ventilation of a development in a mine has been prepared and signed no change should be made in the proposed system of ventilation without the agreement of all signatories of the said plan.
|
| | (6) |
Any change made in a ventilation circuit should be recorded forthwith on the rescue and ventilation plans. Furthermore, a joint working party should be set up to review the frequency of updating all statutory plans and the available methods of plan reproduction so as to reduce the time between survey and issue.
|
| | (7) |
The equipment to enable deputies to detect flammable gas in extensive roof cavities should be readily available where needed. Such cavities should be positively ventilated or filled.
|
| | (8) |
At large collieries consideration should be given to the appointment of a chief engineer to coordinate the activities of the electrical and mechanical engineering departments. Where there is no chief engineer arrangements should be made to ensure that in respect of matters likely to affect safety, there is a daily exchange of information between the mechanical and electrical engineers for the mine.
|
| | (9) |
The National Coal Board should provide effective means for the immobilisation of apparatus which may be dangerous by reason of some mechanical or electrical defect or abnormality.
|
| | (10) |
The National Coal Board should review the appointment of deputy managers and safety engineers at collieries. The provisions of Section 1 of the Mines Management Act 1971 should be more widely applied in this respect.
|
| | (11) |
The duties of safety officers, ventilation officers, roadway dust samplers, and stone dust barrier supervisors should be specified in writing by the colliery manager.
|
| | (12) |