Appendix III.
National Coal Board Directive On Provision Of Two Intake Airways
1. The Board have decided as a matter of policy that the provision of two main intake airways as required by Section 42 (1) of the Coal Mines Act, 1911 (subject to the exemptions and exceptions provided therein and in General Regulation 89 of 10th July, 1913,), shall be extended as follows in any seam newly opened, and in the further development of any seam already opened unless in the latter case the anticipated length of life of that part of the mine or the number of men to be employed does not justify the provision of two main-intake airways.
2. For each part of the mine having a main transport system serving more than one ventilating district, two main trunk intake airways (which shall be of such size and shall be maintained in such conditions as to afford a ready means of ingress and egress) shall be provided from the entrance to the seam (except within the distances from the shaft or outlet fixed in General Regulation 90 of the 10th July, 1913,) to the point where the last split is taken to ventilate any district of the mine:
Provided that :—
| | (i) |
two main trunk intake airways as aforesaid shall not be required if the number of persons employed below ground on any one shift in that part of the mine does not exceed 100;
|
| | (ii) |
in the case of a seam entered by a cross-measure drift from the surface or from the shaft bottom or from another seam, the "entrance" to the seam shall be the point where the cross-measure drift strikes the seam
|
| | (iii) |
two main trunk intake airways as aforesaid shall not be required in the case of drivage through old workings or goaf existing at the date of this directive.
|
3. In respect of each ventilating district where any working face is more than 1,000 yards from the main transport system, and where an inflammable belt conveyor exceeding 250 yards in length (other than a face conveyor) is installed; the two main-intake airways shall be extended to the working face
Provided that this requirement shall not apply :—
| | (i) |
if the number of persons employed below ground in that district on any shift does not exceed 50;
|
| | (ii) |
in the case of drivage through old workings or goaf existing at the date of this directive.
|
4. Where part of the workings in a seam is connected to workings in another part of the same seam by means of cross-measure drifts, owing to faults or other natural disturbances in the strata, the two intake airways need not be provided through or beyond the cross-measure drifts if they are not justified for the reasons given in paragraph 1.
5. This directive shall take effect forthwith in respect of newly-opened seams and on the 1st January, 1952, in respect of further development of any seam already opened.