Appendix II
Special Code of Precautions to be observed in the working of seams subject to outbursts of Coal and Firedamp in the Anthracite Area of South Wales
In the light of the occurrence of outbursts on a longwall face and having in mind the increasing experience of the firing of rounds of shots to induce outbursts, the Committee decided that a review of the existing Code of precautions was necessary.
However, the Committee realises that further research is necessary and this is actively proceeding. It follows, therefore, that the present revision is not necessarily final.
The revised Code is appended:
1. The precautions should be observed in such mines and seams and subject to such conditions as may from time to time be agreed and specified by the Committee.
2. Where practicable, having regard to all factors relating to safe working, the seam least liable to outburst should be worked first.
(Appendix I).
3. The normal method of working should be longwall with straight faces and without acute angles at the fast ends of the faces. There should be a high standard of roof control. Every effort should be made to provide an adequate travelling way along the face at all times.
4. Each production face should be provided with unit ventilation as soon as practicable after its commencement.
5. Holes in coal should not be drilled by percussive means and pneumatic picks should be prohibited:
(a) in narrow drivages;
(b) on longwall faces where conditions liable to outbursts exist.
(Appendix II).
6. If, in the opinion of the Manager, conditions liable to outbursts exist on any longwall face, inducer shotfiring should be practised. (Appendix III).
The firing should extend for at least ten yards on each side of the disturbance, or to the end of the face if that is less than ten yards away from it.
7. In narrow drivages in coal all the material should be got by inducer shotfiring over the whole face of the heading in one operation.
Temporary and permanent supports should be erected as soon as possible after firing and as close as possible to the face of the heading.
8. In the driving of stone headings as many pilot holes as are required to give adequate information on the nature of the ground being approached should be maintained at least five feet in advance of the back of the next lift. Should a pilot hole prove either a seam of coal 12 inches or more in thickness or ground which is considered liable to outburst, the following additional precautions should be taken:
| | (a) |
inducer shotfiring should be adopted covering the whole face of the drivage in one operation;
|
| | (b) |
where the presence of a seam has been proved, the depth of the shotholes should be adjusted so that in the firing of the round of shots that reaches the seam, the whole or as much as possible of the seam should be penetrated;
|
| | (c) |
temporary and permanent supports should be erected as soon as possible after firing and as close as possible to the face of the heading.
|
9. Whilst inducer firing is proceeding, no persons should be on the return side of the place concerned and the persons engaged in firing the shots at least 200 yards away from that place.
| | (i) |
not more than three persons should be so engaged;
|
| | (ii) |
there should be ready means of communication between the firing station and the surface. Before firing, a message should be sent to a responsible person on the surface who should stand by until notified that the shots have been fired and the examination completed;
|
| | (iii) |
the examination after shotfiring should not be carried out until 20 minutes after firing of the shots. Two persons, including the person firing the shot, should test for gas at intervals of not more than 50 yards as they proceed.
|
10. Where stables on longwall faces are more than six feet in advance of the working face, such stables should be considered as narrow drivages.
(Appendix III).
Appendix I
Experience in many countries has shown that if a seam not subject to outbursts is worked before adjacent seams which are so subject, the risk of outbursts is very much reduced when these seams come to be worked subsequently.
The Committee recognises that in some circumstances the relative positions of the seams may be such that the best sequence from outburst considerations would be wrong so far as strata control is concerned, and realises also that further research is desirable to find the depth to which the relieving action is effective. However, the possibility of avoiding outbursts by a better sequence of working must be a main consideration in planning operations.
Extraction should be complete, because pillars left inside goaved areas cause concentration of stress in underlying and overlying seams.
Appendix II
The Working Party considers that rotary boring is less likely to initiate an outburst than percussive boring. However, they feel that other steps proposed should prove better safeguards and they do not consider that rotary boring should be insisted upon in stone where its adoption would entail a longer time of risk or would impede the carrying out of other precautions.
Appendix III
When considering whether or not conditions liable to outbursts exist, the Manager should have regard to any structural change in the coal seam or adjacent strata, such as faults, folds, rolls thinning or thickening, and soft coal.
Experience in other countries, and to some extent in this country, has shown that the firing of a large round of shots may precipitate an outburst at a time when no one is exposed to risk and by this means may avoid outbursts when persons are working in the vicinity. The more violent the shocks given the more likely is the action of this inducer round to be effective, and it is certainly undesirable that a shotfirer should have to make a second approach to a place in order to complete firing operations. For effective inducer firing, therefore, rounds of more than six shots and an exploder of a type not generally approved for use below ground are necessary.
HM Chief Inspector of Mines has indicated that he will give favourable consideration to any necessary relief from statutory requirements to enable inducer shotfiring to be carried out, subject to suitable precautionary conditions. An essential part of all inducer firing operations will be that no person shall be exposed to risk during the firing of the shots. No person shall be within 200 yards of a place in which an inducer round is to be fired, nor approach within that distance until 20 minutes after the shots have been fired. No person shall be on the return side of the place. The conditions of exemption will also require stringent examination for firedamp.
Joint Advisory Committee on Outbursts of
Coal and Firedamp — Meeting 7 July 1959
Addendum to Code of Outbursts Precautions
Where electric power is used at the face, it shall be switched off prior to the carrying out of inducer firing'.