Introduction
1. In accordance with your direction given under Section 121 of the Mines and Quarries Act 1954, I beg to submit my report on the causes of, and circumstances attending, the spontaneous outburst of coal and firedamp which occurred at Cynheidre/pentremawr Colliery, Carmarthenshire, at about 12 noon on 6 April 1971, when six persons were killed and sixty-nine others suffered varying degrees of asphyxia. Three of the men died in the Road 2 Development and three others in Panel 13, a highly mechanised longwall district around which the firedamp was carried by the main ventilation system. The names, ages and occupations of the men are given in Appendix I to this report.
2. On 4 June 1971 Mr. J. E. G. Roberts, H.M. Coroner for the Three Commots District of Carmarthenshire, sitting with a jury of eight persons concluded the holding of an Inquest and I welcome this opportunity of expressing my appreciation to the Coroner for his courtesy in allowing me to sit with him.
3. It was found that, in accordance with the medical evidence, the men died from asphyxia following an outburst of methane gas from the Road 2 Cross-cut Drivage in the Cross Measure 2 Section of Workings in the Big Seam.
Description of the Colliery
General
4. The Cynheidre/pentremawr Colliery is in the West Wales Area of the National Coal Board and is situated some five miles (8 kilometres) North of Llanelli, Carmarthenshire, at the Western extremity of the coalfield. Cynheidre and Pentremawr Collieries were linked underground in 1966 and came under one manager in 1970. The Pentremawr Colliery began production in 1875. Sinking of the shafts at Cynheidre Colliery commenced during 1954 and production began in 1960. At the time of the outburst the combined colliery produced about 20,000 tons (20,320 tonnes) gross each week and employed 1,178 men underground and 422 on the surface.
5. There are two downcast shafts, two upcast and three intake drifts, all lying within a circle having a radius of 1.5 miles (2.4 kilometres). The No. 1 Downcast and No. 2 Upcast Shafts are 24 feet (7.3 metres) and 20 feet (6.1 metres) in diameter respectively and are both at Cynheidre. The No. 3 Upcast and No. 4 Downcast Shafts, each 18 feet (5.5 metres) in diameter, are three miles (4.6 kilometres) North-East of Cynheidre, near Tumble. The three intake drifts are all at Pentremawr, two miles (3.2 kilometres) North of Cynheidre.
6. The No. 2 Upcast Shaft is equipped with an electrically driven Davidson Sirocco fan extracting 370,000 cubic feet per minute (175 cubic metres per second) of air at 8 inches (20.3 centimetres) of water gauge. The No. 3 Upcast Shaft is equipped with an electrically driven Davidson Sirocco fan extracting 220,000 cubic feet per minute (104 cubic metres per second) at 10.5 inches (26.7 centimetres) of water gauge.
7. Approved electric cap lamps are in general use and flame safety lamps are issued to officials and selected workmen as firedamp detectors. Methanometers are carried and used by the ventilation staff and certain senior officials.
8. The colliery is divided into five main Sections, each of which has a separate ventilation circuit. The outburst occurred in the Cross Measure 2 Section of the mine and much of this report is concerned only with this part of the mine.