|
By Electricity. Five persons were killed by the same number of accidents due to electric shock. I give below a more detailed description of them than appears in Appendix I, as they suggest means which should be taken to prevent similar accidents in future. I was not in charge of the district when the first four of these accidents occurred, and I, therefore, give below a summary of the reports made by Mr. Nelson, His Majesty's Electrical Inspector of Mines, on them. The second accident occurred at Bardykes Colliery, belonging to the Summerlee Iron Company, Limited, on May 5th. The deceased boy was a putter, but he was seated close to a switch controlling the running of a coal conveyor at the time of the accident. The system of supply at this colliery is three-phase 500 volts, the neutral point being insulated. Current is used for haulage and for driving coal conveyors. In the latter case current is led to a triple pole oil switch, mounted on a wooden stand and fixed at a point 10 or 20 yards from the coal face. Between this switch and the conveyor motor is a coil of cable which is payed out as the coal conveyor motor is moved forward. The switch is mounted for firmness on a wooden stand. From the evidence given at the inquiry, the conveyor had been stopped for some repairs, and the lad had therefore nothing to do. He seated himself by the switch, but when the attendant went to switch on current after an interval of about a quarter of an hour he was found to be dead. There is no doubt that deceased's death was due to electric shock, but there is no positive evidence as to how he received it. A piece of wire about 12 inches long was found hooked on to the side of the switch box, and this wire had evidently from its appearance (small globules of metal) carried current at some time or other. On top of the switch were several rows of terminals protected by a metal cover, but between this cover and the switch top on each side was a clear space of about ½ inch by 6 inches. One of these terminals showed signs of arcing, as to a small piece of wire such as that found. This evidence, coupled with the fact that the switch was tested and examined and found to be in order after the accident, suggests that the deceased was himself responsible for his own death by thrusting the wire, which was found hooked on to the side of the switch, underneath the protective cover until he touched a live part. This theory is in some small measure confirmed by the fact that the wire had evidently at some time carried current. The jury found a verdict of "death from electric shock received in some way unknown." An effort was made to restore deceased but without result. The only complete remedy is the enclosure of all live parts, so that, there is no temptation to experiment, The Company have filled up the open spaces at the sides of switches of this pattern since the accident, and one switch has had its terminal box filled with compound. This latter is no doubt a sound precaution, and if all were done it would also provide a saving as regards upkeep, for then no inspection and cleaning of terminals would be required. Source: 1910 Mines Inspectors Report (Cd 5676), Scotland District (No. 1) by W. Walker, H.M. Inspector of Mines, Page: 20 Where to find this report
|
|||||||||||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 31 Dec 2022
|
Search |
|
|||