Loss of life by Suffocation, at Nut Grove Colliery, St. Helens. The manager, the surveyor, and one of the workmen of this colliery were suffocated in foul air while attempting to extinguish a fire in one of the thick mines of this colliery, which had become ignited by the cinders from a fire-grate in the upcast pit, which had been placed there to produce ventilation. It appeared that the heat had caused the upcast pit to collapse, so that the smoke and vapour arising from the fire, together with the carbonic acid gas of the mine, filled the bottom wagon road from the downcast pit. As far as I could ascertain, they were examining the stoppings which had been put in to keep it back, and to prevent the access of air to the fire. As this mistake is often made, it is necessary that I should again explain my views on the subject. When it becomes necessary to extinguish a fire below ground, the top of the pit or the entrance to the mine at the bottom should be hermetically closed, so that no air can reach the fire. A pipe to allow the escape of gas should be fixed in the stopping in the upcast pit. If that be properly done, the fire will go out, and the heat gradually cool down in a short time. The bottom of the upcast had not been regularly examined, and the pit was only used for the egress of the return air. It was lowered and raised by a windlass on the top. Source: 1868 Mines Inspectors Report, South West Lancashire and North Wales District by Peter Higson, H.M. Inspector of Mines, Page: 46
|
|||||||||||||||||||||||||||||||||||
![]() |
||||||||
|