Explosion of Gas, Llantwit Colliery. This is another colliery belonging to Messrs. Powell and Son. I have had in a previous year to report an explosion of gas at this mine. The quantity of air circulating through the works, when I made an examination, was inadequate, and the airways far too small ; and in this particular case the brattice was not sufficiently near to the working place to dilute the gas given off. It is not by any means a "fiery mine," and with care and proper windways it ought to be safely worked. Source: 1860 Mines Inspectors Report, by Thomas Evans, H.M. Inspector of Mines, Page: 117
|
|||||||||||||||||||||||||||||||
![]() |
||||||||
|