Page Bank Colliery Inquest
Extracted from the Annual Mines Inspectors Report for 1858
While the operations for extinguishing this fire were going on there was, at one time, as many as 13 fire engines on the place ; the supply of water from the river, was, however, upwards of 300 yards from the shaft, which rendered them much less efficient than they would have been had it been obtainable nearer the pit.
It was not until Sunday evening after the discovery of the fire that the burning blower of gas in the shaft was finally extinguished by exploding, in quick succession, five quarter barrels of gunpowder, which were lowered down the shaft, on the winding rope, to the point where it was given off ; several ineffectual attempts had previously been made by exploding smaller quantities of gunpowder from a cannon and other contrivances.
During the progress of the repairs of the shaft there were times when the discharge of gas was so great as to render explosive the atmosphere on the surface at some distance from the top of the pit.
I am still of opinion that the furnace was the primary cause of the fire, and think it highly probable that a spark from it had, in the first place, ignited soot in the furnace drift or shaft, and that the fire had by it been transmitted to some small jet or escape of gas from behind the plank tubbing, which had continued to burn a sufficient length of time to ignite the timber composing the shaft brattice and plank tubbing.
After the inquest was over, I was informed by Mr. William Hall that the shaft had been examined by John Mould the overman, the deceased, Thomas Kellet, and himself; on the night before the morning on which the fire was first discovered, and that they then saw no signs of any fire in the shaft.
In my opinion this accident, although one of a character that has rarely, indeed, if ever before, proved fatal to life, indicates that very great and constant attention should be paid to the examination of upcast shafts and drifts containing combustible materials, such as timber and exposed coal, in all cases where ventilation is produced by the action of furnaces; and that the soot accumulating in them should be kept in a wet state by the constant application of water, and cleared away at very short fixed intervals.
That the general safety of a colliery is greatly enhanced by having more than one shaft or opening from the surface to the mine there can be no doubt, although, had there been another shaft at Page Bank Colliery, set apart as an upcast, without any provision immediately available for quickly drawing the workmen up it to the surface (as is but too frequently the case under such circumstances), it seems most probable that the smoke from the fire in the downcast shaft (supposing it to have arisen from a spark of a torch) would have been carried by the air into all the workings of the mine, and finally up the upcast pit, in much larger quantities than was the case in this instance, and therefore have caused a much greater loss of life.
The upcast staple of the Page Bank Colliery was so much damaged by the fire as to require to be filled up and abandoned, and a second shaft is now being sunk.