29th May 1943, Page: 284, Column: 1 High Tension DetonatorsThe paper — "Practical Notes on the Firing of Some High Tension Detonators" — presented by Mr. Alan L. Ford, M.I.M.E., before the North of England Institute of Mining and Mechanical Engineers, was based on experiments undertaken on hearing that a shot-firing accident had occurred through a high tension detonator being inadvertently connected to signalling wires carrying a pressure of not more than 25 volts. It seems that some definite instructions should be given to shot-firers as to the methods they should adopt in running out their cables. Assuming that the shot-firer has carried out all his statutory duties, and that the shothole has been correctly charged, it is suggested from the point of view of safety that the coiled cable be taken to the charged hole, tied near one end to a prop or other convenient place, leaving sufficient length to enable the shot-firer to attach the cable end to the detonator lead wires, then connect up to the detonator wires and run the cable out to the firing point. Mr. Ford gave the advantages of this method as : (1) The cable being moored to the prop, no strain is put on the connection between the detonator lead wires and the cable. (2) The shot-firer, having control of both ends of his cable, is able to ensure that it does not come in contact with any wires, cables or other electrical apparatus. (3) The cable is not likely to be damaged by gear, etc., being dropped on it inadvertently between the time of laying it out and the firing of the shot, as the shot-firer should be the last man to leave the place. The Author proceeded to say that the high tension electric detonator differs from the low tension in the fact that, while in the latter type ignition of the fusehead composition is obtained by a thin bridge wire being heated by the passage of an electrical current, in the high tension type there is no bridge wire, but instead graphite is incorporated with the fusehead composition so that this becomes a partial electric conductor and is itself ignited in microscopic localities by the passage of electric current. In the construction of a high tension detonator the fusehead consists of two metal foils attached to the opposite faces of a strip of insulation. One end is dipped several times in baths of paste composed of ignition composition, etc., and the match head gradually built up. Ultimately the detonator lead wires are soldered to the opposite end of the fusehead. The resistance of a high tension detonator varies from 1,500 to 50,000 ohms, and the Explosives in Mines Research Committee states that high tension detonators must not fire when 5 volts is applied for one minute but must fire when 50 volts is applied for 50 milli-seconds. In actual practice, however, it is difficult to obtain 50 volts for 50 milli-seconds from an approved high tension exploder, and users have to rely upon detonator manufacturers maintaining the sensitiveness of the fuseheads at a level which will allow them to be fired at appreciably lower voltages. Giving the results of the firing of a number of detonators, Mr. Ford said that in three cases there was no time lag between the application of the current and the firing of the detonators, while in seven cases the lag varied from 2 to 14 seconds, and that the remaining detonator did not fire, although 22 volts were applied for 60 seconds. This detonator was fired with no difficulty by an approved high tension exploder. In the fifth test an intrinsically safe electric bell was coupled into the circuit to reproduce actual pit conditions where a shot-firer might couple up a detonator to signal wires. At this stage it was learnt that the effect of repeatedly passing currents through a fusehead, if insufficient to fire it, is to lower its electrical resistance and thereby alter its firing characteristic. Having discussed the results of a final series of tests designed to find out the effect of intentionally using the wrong type of exploder for firing the respective detonators in use, and of attempting to fire a number of detonators simultaneously, Mr. Ford said that, as a matter of interest, both high- and low-tension detonators were coupled up, in turn, to a telephone circuit. For these tests two magneto-call certified intrinsically-safe type telephones were connected by a 50-yard shot-firing cable. These tests resulted in a low-tension detonator not firing, but a high-tension detonator fired at once, and as many as six, when connected in parallel, also fired. Two high-tension detonators coupled- in series did not fire. The tests have given a splendid opportunity of impressing on all who came in contact with them the care needed in shotfiring and handling detonators.
|
|||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||