9th January 1943, Page: 160, Column: 1
Life-Saving By Barricades
Practical Observations
By D. Harrington and W. J. Fene.
[Note. — After mine explosions and during mine fires deadly gases
spread through the workings and imperil the men who survive the violence or the
heat. At such times many miners have saved their lives by building barricades
to protect themselves from such gases, but many others have lost their lives by
neglecting to do so. This question is fully dealt with by the United States
Bureau of Mines in Miners' Circular 42, which has been written in the hope that
any miner who may be trapped in a mine by an explosion or a fire may escape
death by knowing how others have saved their lives by sealing themselves
promptly behind well-located and well-constructed barricades, bulkheads or
stoppings. The authors of the Circular are Messrs. Harrington and
Fene of the Bureau Safety Division. The price of the Circular is 10
cents net, and it is on sale by the Superintendent of Documents, Washington,
D.C. There are 64 pages of text with 40 illustrations. Practical
recommendations by the authors are appended).
1. When miners are entrapped by gases from fires or explosions and forced back
into workings in which there is comparatively good air, they should give
prompt, careful thought to trying to shut themselves away from oncoming
poisonous gases by building a bulkhead or stopping in such manner as to prevent
poisonous gases from entering the region to be barricaded or shut off.
Notwithstanding the strain they are under when entrapped, they should try to
keep cool and not rush aimlessly around trying to get out. As far as possible
they should weigh their chance of escape, and if they find escape is blocked
they should prepare to do everything possible to save themselves.
2. They should collect tools, timber, boards, canvas, brattice cloth, water,
dinner buckets, hay from the stable, and anything else that might be useful,
and should try then to find a place near by where the air is still free of gas
and which is or can he made tight so as to keep out smoke and gases. The place
should enclose, if possible, several rooms or several hundred feet of entries,
so as to have a large volume of fresh air in reserve.
3. As soon as a place is chosen for a barricade its erection should begin, for
the gases often travel quickly. A suitable barricade can be erected in 30
minutes to a few hours, but every effort should be made to have the stopping
made as tight as possible so that the poisonous gases cannot leak through into
the barricaded region.
If compressed air is used, the barricade should be near a valve in the
compressed-air pipe line ; the valve should be opened to furnish additional air
within the barricaded region. If there is no compressed air the next best thing
for miners behind a barricade to do is either to lie down or sit on the floor
in the hope that the rescue crew will find them before they are overcome. In
this relaxed position they will breathe much less air than if they exert
themselves ; however, they should not lie too close to each other, as they may
exhaust the oxygen at that one place while plenty of oxygen may be available 25
to 50 feet away.
4. The ventilation current outside the proposed barricade should be shut off or
short-circuited as soon as possible by opening doors and hanging brattice cloth
or by moving a door to a new place across an entry, or the air may be
short-circuited by knocking out one or more stoppings.
5. It is important always to barricade off as much underground opening as
possible (entries, rooms, drifts, crosscuts, and stopes) without regard to the
number of men in the party, so as to provide the largest possible amount of
fresh air.
A bulkhead drift about 250 feet long, 6 feet high, and 6 feet wide, containing
about 9,000 cubic feet of air, kept 29 men alive for 36 hours in a very
disastrous metal-mine fire. Another one about 130 feet long, 7 feet high, and 7
feet wide, containing about 6,500 cubic feet, supported 6 men for 50 hours ;
however, in the latter instance 8 persons were behind the barricade originally,
and 2 died before the end of the 50 hours, probably because the men all sat
together and consumed the oxygen where they were sitting, though there was
plenty of good air 50 feet away and within the barricaded region. The 6 men who
were saved were taken out unconscious but recovered in the hospital. If the 8
men had been distributed over the barricaded region, or if they had taken turns
walking back and forth to keep the available air well mixed, all 8 probably
would have escaped alive.
6. Before a bulkhead is constructed it is important to make sure that there is
no manway or crosscut or other open connection with other workings through
which gases could come. Moreover, it is important that the workings being used
back of the barricade are not in broken ground or in ground stoped through from
a lower or higher level and back-filled with loose rock through which gas could
find its way ; if in broken ground, even if the bulkhead is made tight, the
enclosed space will be likely to fill with gas that leaks through the broken
ground, and several attempts at barricading have resulted in failure for this
reason.
7. If more than one stopping is built (and generally it is desirable to erect
at least two stoppings) it is important to place a sign of some kind outside
the first or outside stopping to show that men are behind it.
8. If a barricade is made of lumps of coal, slate, or other rock or ore it is
important to build two walls 2 to 3 feet apart and to fill the space between
them with fine material or mud. The stopping must be essentially air-tight, or
it is likely to leak, hence fail to protect the entrapped persons. Board
stoppings are not as easily made gas-tight as those built of dirt or rock and
dirt, particularly if the dirt is in the form of mud or soft clay.
9. To get full benefit from barricading it is important that all chinks and
holes in the barricade should be made thoroughly tight with clay, rags,
clothes, or similar material. Failure to make stoppings to a barricaded region
tight enough to prevent poisonous gases from an explosion seeping in has
resulted in loss of lives that very probably would have been saved had the
stoppings been constructed effectively.
10. Before they begin to build a stopping coal miners should remember that they
should not barricade themselves in any place that gives off gas (methane)
freely ; firedamp may accumulate and be ignited in some way and cause the death
of the whole party, or the entrance of the explosive gas may so reduce the
proportion of oxygen as to cause the atmosphere to be deficient in oxygen,
hence dangerous to breathe.
If carbide lights are used, the number kept lighted should be held down to one
or two, and the more or less spent carbide in the unlighted lamps should, if
possible, be thrown outside the barricade so as not to contaminate the
barricaded region with noxious (explosive) gas. If the workings give off
explosive gas it may be necessary to cease using carbide lights within the
barricade. If electric cap lamps are used it may be wise to keep only one or
two lighted to save the battery charge in some lamps to give light when others
have become exhausted.
11. If a compressed-air pipe with hose attached leads into a drift, entry, or
room, and gas is coming in while the bulkhead is being erected, it would be
good policy to station a man to blow air to keep back the gas ; this has been
done in connection with fires in metal mines.
12. If available, a piece of pipe should be placed through the stopping and
plugged at the inner end, so that the air outside the barricade can be tested
from time to time by removing the plug. This testing should be done carefully
and the pipe kept plugged when not in use.
13. To conserve the oxygen of the air after the barricade has been built the
men should remain as quiet as possible, as a man exerting himself uses
essentially twice as much oxygen as one who remains absolutely quiet. However,
somebody should walk around occasionally to mix the air, and all the men should
not congregate in one place. Moreover, as previously indicated, if carbide
lamps are used only one or two should be kept lighted, and the more or less
spent carbide in the unlighted lamps should be wasted outside the bulkhead if
possible.
14. After the bulkhead has been erected, it should be tested for leaks by a
flame safety-lamp, candle, or carbide lamp, if available.
15. The way in which the flame of a lamp or candle burns will show the
condition of the confined air and how the oxygen is being exhausted. All flame
lamps (except possibly one for part of the time) should be extinguished to save
oxygen; moreover, oil, carbide, and electric batteries should not be used
needlessly. Food and water, of course, should be used sparingly and thereby
kept as long as possible.
16. Men behind a barricade should signal frequently by pounding on the air or
water pipes, the track rails, or the back of the rock drift, or, in a coal
mine, by pounding on the rib or the roof so that listeners may hear them.
Generally, pounding on the rock or coal can be heard farther than pounding on
pipe lines or track rails.
17. Miners should carry with them any chalk found during their retreat from
gases ; chalk also may be part of the working equipment of track men, fire
bosses, shift bosses, etc., who may be among those entrapped. Directions for a
relief party may be written on doors, or an arrow may be drawn on a track rail
or a pipe or a piece of board or slate or on the roof or rib to indicate the
course the workers took in retreating. Under some conditions the flame of a
carbide lamp will enable a mine worker to make good lettering on timber or
rock.
18. It is very important for underground employees to be familiar with all
escapeways, manways, and other exits in addition to those usually travelled ;
in many mines this is not the case, and many lives have been lost as a result
of failure of the supervisory force to inform workers about this really
important matter. Workers should learn, also, which entries serve for intake
and return air-currents ; here, again, is an important safety feature very
frequently neglected by both workers and bosses. A mining company should equip
all parts of a mine with direction signs, which should be kept in readable
condition. Often this is not done. Travelways to emergency exits should always
be kept in passable condition, reasonably free from rock falls, pools of water,
and other obstacles, another safety feature neglected far too frequently.
 |
 |
|
Names mentioned in this article
|
 |
 |
| Name | Age | Occupation | Notes |
| Fene, W. J. | | U.S. Bureau of Mines | |
| Harrington, D. | | U.S. Bureau of Mines | |