9th January 1943, Page: 158, Column: 1 Coal For Steam RaisingAppended are abstracts from the paper on "Coal for Steam Raising" (See also No. 10, page 114) prepared by Mr. J. N. Waite for presentation to the Institution of Electrical Engineers. Volatile Content. Generally speaking, fuel having a volatile content of less than 11 per cent. requires the adoption of pulverised-fuel firing, while with fuels having a higher volatile content there is a choice between various types of mechanical grates with balanced draught or pulverised fuel. In all cases the design of the furnace and the combustion equipment is governed largely by the volatile content of the fuel. The choice of a fuel may to a limited extent be widened by judicious blending, but it should be realised that such blending should produce a homogeneous mixture and should be with coals having somewhat similar characteristics. The practical aspect of volatile content may be visualised from the fact that combustion rates with high-volatile coal range up to about 50 lb. per square foot per hour in practice, while with low-volatile coal the maximum rate of combustion is not more than about 30 lb. per square foot per hour. This, and the fundamental difference in the combustion process, makes it essential for boilers to be supplied with coal having a volatile content approximating to that for which they were designed. Any serious departure from this will lead to a depreciation in performance. The first requisite is consistency in value. Coal Size. At one time, the supply of small-sized coal exceeded the demand, with the result that the price of small coal was relatively low. This led to the development of combustion apparatus which would deal effectively and efficiently with small coal as a fuel for power production, and to-day it may be said that types of combustion apparatus are available which will deal effectively with the smallest-sized coal produced. There exist, however, practical upper and lower limits for coal size for different types of apparatus, which are well known both to the coal trade and to power producers. Agreed nomenclatures and standards of grading for size are long overdue, and it is to be hoped that the British Standard Specifications for sampling, analysis and testing of coals and coke will bo extended to cover analysis and definition of size. The present system of nomenclature is chaotic and leads to unnecessary confusion and difficulties. The more uniform the size of the coal for mechanical stokers, the less likely becomes segregation of size in the bunkers, chutes and on the grate. If a mixture of relatively large and fine coal is used some amount of segregation will always occur. It should be borne in mind that even if the large and small particles are intimately mixed at the colliery all the processes of handling tend to bring about segregation of size, and the greater the difference in size the greater the tendency to segregation. If the best possible result is to be obtained, it is essential that the size range should not spread beyond well-known limits. Where there is a wide variation in size the larger particles will ignite more slowly, and thus will be carried farther along the grate before combustion is well under way. They may actually arrive at the dumping bars before combustion is completed, while the smaller-size coal has long completed its combustion, thus leaving bare patches through which air will flow and thus lower the CO2 and boiler efficiency. This gives rise to two preventable losses. In addition to the effect on efficiency, variation in size beyond definite limits has an effect on boiler output, for the rate of combustion has to bo controlled to suit the largest size. Generally speaking the less the range in size, the better the result from an operating point of view. It is obvious that proper grading of size has a definite commercial value to the power producer. The limits of size for particular types of combustion apparatus are well known. If the limits are exceeded, loss of efficiency occurs and operation becomes more difficult. It should be emphasised that it is consistency that is primarily required. The same size range should be supplied all the time to particular plants. Coal Cleaning. A considerable quantity of coal is already subjected to cleaning processes. The annual report of the Mines Department states that in 1938 the tonnage cleaned for that year was 103.2 million tons, which equalled 45.4 per cent. of the total saleable output. Of the total mechanically cleaned 82.3 per cent. was dealt with at washeries, 15.5 per cent. at dry cleaning plants, and 2.2 per cent. at flotation plants. The need for cleaning is obviously recognised, but there seems to be good grounds for believing that most of the cleaning in use may be legitimately termed partial cleaning, and that while the existing cleaning is of great value in removing some of the foreign matter and thereby enhancing the value of the coal treated it does not remove the whole of the foreign matter. The savings which would accrue from the use of completely cleaned coal for steam-raising purposes having an ash content approximating to the inherent ash value can be conveniently summarised under four main headings :— (a) Gain due to reduction of sensible heat loss in ash. (b) Gain due to increase in boiler efficiency due to loss unburnt carbon enclosed in ash, etc. (c) Gain due to reduction in cost of removing grit, ash and clinker from the boiler, reduction in cost of cleaning and soot blowing, reduction in capital cost of ash handling and cleaning equipment, etc. (d) Gain due to saving in cost of transport. There seems to be little doubt that an economic case exists for the complete cleaning of coal and the removal of superfluous or foreign matter prior to dispatching to the user. It would appear probable that whatever methods are evolved for the complete cleaning of coal, they would all necessarily include for the removal of the very fine particles of coal and foreign matter which may be classed as dust as a preliminary process. Even if this dust removal were not necessitated by the cleaning process, it would be a great advantage from many points of view if the dust were separated out and dealt with as a separate product from the remainder of the coal. The advantages of having a dust-free coal for all types of mechanical grates are too obvious to need recital and it appears certain that advantage would accrue from dust removal in the coal for gas production and metallurgical coke production. If coal production, distribution and utilisation is to be planned to get the best use of our nation's most valuable product, there seems to be no doubt that complete cleaning of coal should form part of such planning. There is also no doubt that better collaboration between users and producers of coal would lead to more efficient utilisation of the nation's coal resources.
|
|||||||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||