26th December 1942, Page: 148, Column: 1
Electricity In Mine Pumping
Extracts from paper on "The Application of Electricity in Mine
Pumping" prepared for presentation to the Installations Session of the
Institution of Electrical Engineers. Date of meeting 10th December.
By G. B. Alvey and N. Tetlow.
Although centrifugal pumps are adopted for the greater range of mine-drainage
duties, there are some duties for which they are not always suitable or
economical.
To apply a centrifugal pump successfully to mine-drainage work, it is first
essential to have a knowledge of the hydrodynamic characteristics of the pump
and of the pipework system through which it is required to discharge.
A centrifugal pump is designed for the specific duty for which it is required,
and its maximum efficiency occurs at one rate of flow and one corresponding net
generated head.
The speed for which a centrifugal pump may be designed is determined by many
factors, the chief of which are :—
(a) The hydrodynamic characteristics required. The pump designer's measure of
the type of pump is its specific speed, where
all these factors being measured at the point of maximum efficiency
(b) The suction performance, or "suction ability" of the pump. This
is one of the most important factors influencing the running speed of a pump.
The peripheral velocity of the vanes at the impeller eye must not, for
instance, exceed the figure at which cavitation takes place.
Sinking and Unwatering Pumps.
During the operation of sinking a mine shaft it is, in general, necessary to
provide pumping equipment capable of removing water from the shaft. A pumping
unit of this type, known as a sinking pump, must be completely self-contained
and must be capable of being moved down the shaft as sinking proceeds. A
similar operation from the point of view of pumping is that of unwatering a
mine which has been allowed to fill with drainage water.
Sinking and unwatering pumps may be either of the centrifugal or of the
positive-displacement type, depending on the duty. The pump, with its driving
motor, suction pipe line and valves, is generally built into a fabricated steel
framework which is suspended in the vertical shaft and can be raised or lowered
at will. Ability to deal with high-suction-lift conditions is an essential
feature because drainage or unwatering can only proceed in steps which are
limited by the suction ability of the pump.
There is a growing tendency to-day in British collieries to centralise
mine-drainage pumping. Disused colliery workings are frequently used for this
purpose and serve as central drainage points for several collieries. If the
shaft is used only for pumping, the surface winding engine and gear may be
removed, so avoiding heavy maintenance costs, routine inspections, etc. Still
further savings can be effected by installing pumping sets of the fully
automatic type requiring only occasional routine inspection. Automatic pumping
sets of this type are usually float-operated from the level of the water in the
sump.
If automatic pumping equipment is to be a success, certain important factors
must be taken into consideration. Precautions must be taken to ensure that the
pump remains fully primed, or is provided with equipment to prime it
automatically when necessary. A ram pump is self-priming within reasonable
limits of suction life. A centrifugal pump, on the other hand, must be provided
with priming equipment.
For driving centrifugal pumps in mines, motors of small, medium and large
capacity are required, usually direct-coupled to the pumps. The drives are
easy, and only comparatively light starting torques are required. For ram
pumps, small- or medium-capacity motors are usually required, and there is
reasonable freedom in the selection of motor speed because the pumps are almost
invariably driven through gears. Ram pumps often start under heavy load.
The driving of mine sinking pumps presents a case where the utmost simplicity
of motor and control gear is especially desirable.
The operation of the motor is sometimes controlled from the surface of the
mine, in which case three conductors only are required where direct-on-started
squirrel-cage machines are installed, as against the six conductors which are
necessary between motor and surface where wound-rotor or star-delta-started
squirrel-cage machines are employed. If controlled from the sinking pump
staging a wound-rotor motor or a fractional voltage-started squirrel-cage motor
requires additional control gear and connections on the staging, whereas the
direct-on-started machine requires only a triple-pole switch of the simplest
type and readily affords the necessary mechanical protection. Another objection
to the wound-rotor machine lies in the reduced reliability resulting from its
insulated rotor winding and slip-rings, under the arduous conditions imposed by
this service, including the probability of considerable vibration. A
squirrel-cage motor is obviously much better able to contend with such severe
conditions.
The type of motor and method of starting employed for pumping service in a mine
may affect the characteristics of the whole of the switchgear installation,
particularly if the pump motors are large compared with other motors in the
mine. For example, the overload protective features of all switches in circuit
with such motors must withstand the starting currents and afford at least
short-circuit protection to the cables. For normal squirrel-cage motors,
started on fractional voltage, the initial starting currents are usually
relatively low, but at change-over from fractional to full voltage heavy
transients occur. Heavy transients are also liable to occur when wound-rotor
motors are switched in circuit.
With squirrel-cage motors designed for direct-on switching with low starting
current, however, it is unusual to find high transient currents at
switching-in. On the other hand the switch-gear must be designed to deal with a
relatively high current maintained for a few seconds. It is obvious that this
requirement may necessitate features in the main switchgear differing from
those required for other starting methods.
Motors of medium and large sizes driving main drainage pumps in mines are
usually of the ventilated type with drip-proof or splash-proof enclosure.
Squirrel-cage induction-type motors are almost unaffected by any reasonable
amount of dirt, and since these motors usually run for long spells, without
extended idle periods, the windings are quite unaffected by ordinary humid
atmospheres, provided they are suitably insulated and impregnated.
Direct-current motors, which are much more susceptible to the effects of dirt
and grit, may with advantage be provided with an air filtering system.
Main drainage pumps in collieries are often installed at or near the bottom of
the downcast shaft, and the motors in such cases may therefore be of the
ventilated type, but conditions sometimes require flameproof construction.
Auxiliary drainage pumps, being frequently installed near to the coal face,
more usually require motors of flameproof design. If a fully flameproof motor
is required, total enclosure of the whole machine is of course essential, and
the incidental advantages and disadvantages of this type of enclosure must be
accepted.
When, as is usual in colliery practice, the main pumping plant is installed at
or near to the bottom of the downcast shaft, it is an easy matter to provide an
adequate supply of fresh air for the purpose of cooling the motors. In other
mines, large motors are often installed in situations where the supply of fresh
air is insufficient to carry away the heat generated in the motors. The pump
chambers are often cut out of solid rock, therefore being of the smallest
possible dimensions, and the walls themselves are unable to absorb sufficient
heat to keep the circulating air cool.
For main or auxiliary drainage pumps a fully flameproof motor is sometimes
necessary. Then total enclosure of the whole machine is, of course, essential
and the incidental advantages and disadvantages of this type of enclosure must
be accepted. Flameproof motors for use in mines in this country must be covered
by a certificate of flameproofness issued by the Mines Department of the Board
of Trade.
Where a ventilated motor is in almost continuous service, it is only necessary
to protect the windings from falling water, even in very damp situations. If
duplicate sets are installed, running during alternate periods, the windings
will usually remain sufficiently dry, but in some situations it may be worth
while to convey the warm air expelled from the running machine, or a portion of
it, to the idle machine.
If a motor is on irregular or very intermittent duty, some means of maintaining
the windings warm and dry should be adopted. In the case of d.c. motors, one
method might be to pass current through the shunt field coils whenever the
motor is stationary. For a.c. motors the ideal method is to switch low-voltage
current through the stator windings, automatically, when the-motor stops. The
supply may be taken from a suitable step-down transformer, and adequate heating
current is usually insufficient to turn the motor when coupled to a pump.
Alternatively, electric space heaters, also automatically controlled, may be
installed and suitably disposed in the motor frame.
 |
 |
|