In the course of his paper on "The Maintenance of a Good Standard of
Ventilation in Mines" in the current issue of The Sheffield University
Mining Magazine, Mr. A. Wright, M.Eng., discusses the question of air
distribution in the following terms :
To ventilate a large mine satisfactorily the air must be directed along a
number of parallel circuits which, in turn, must be split into other parallel
paths. This practice is essential for two reasons, namely, to keep the total
resistance to air flow to an absolute minimum and to supply as many faces as
possible with intake air. The process is known as "splitting."
Main splits should commence as nearly as possible to the pit bottom. Similarly,
when "splits" are further split it should be done as far outbye as
the layout will permit to give parallel paths for as great a distance as
possible.
Where possible, splits should be so arranged that the introduction of
regulators, as is often necessary in short splits, is avoided since these
absorb useful energy which is almost entirely lost.
Generally speaking, no split should ventilate more than one machine face,
particularly one which is more than 100 yards long. The actual length of face
which can be ventilated by one split will depend upon the ease with which the
gas standard can be maintained and the thickness of the seam. If a face cannot
be properly ventilated by, say, 10,000 cubic feet per minute, it might be
argued that, if the quantity were increased to, say, 15,000 cubic feet per
minute, the gas percentage would be reduced to below the standard value. That
may be true but it must be realised that the air velocity on the face would be
increased by 50 per cent., and this might create very uncomfortable working
conditions both from the point of increased cooling power and from aggravation
by air-borne dust, both likely possibilities in thin seams. In a case of this
kind, the desired result should be obtained by maintaining the quantity at
10,000 cubic feet per minute and reducing the length of the face. Conversely,
in a deep, hot mine, where the gas yield may be small and require oialy a small
quantity of air to ventilate the face and roadways, it would be better to have
fewer splits with a bigger length of face per split and a much higher quantity
and velocity of air.
The direction in which the air passes along a face is also an important factor
to consider. It is common practice when the inclination of a seam is more than
about 4° to have the gates in the direction of the strike and the line of
the face at or about full dip. In these circumstances ascensional ventilation
should be practised as far as circumstances permit. If the air travels down the
face it is possible for firedamp to travel against the air-current unless this
is brisk, an occurrence which is highly undesirable since it means that the gas
is not being cleared into the return. Experimental work on the movement of
firedamp in air showed that in a roadway inclined at 1 in 10 firedamp travelled
up the incline for some distance against an air-current of about 80 feet per
minute.
The point at which the air enters a face is important from another point of
view. The author has seen a number of faces ventilated in a manner he considers
to be bad practice. Two cases will suffice to illustrate the principles.
(a) A district may be ventilated by two intakes usually about 100 yards apart,
both terminating at the face. One of these is generally considered to be the
main intake and splits at the face, air travelling up and down the face, one
side however usually being longer than the other. The second intake is then
said to "freshen up" or "reinforce" the ventilation on the
longer face. Such practice is unsound since it is possible for there to be
little or no pressure difference between the points where the two intakes enter
the face so that a portion of the face between them may be badly ventilated or
completely stagnant.
(b) Often on a double unit face, in order to minimise the air velocity at the
loading point so as to lessen the amount of airborne dust, the main intake to
the face is along one rib side with a smaller quantity of air entering the
face, about the middle, from the loader gate. In a gassy seam this is bad
practice since, strictly speaking, the second face is ventilated by partly
vitiated air. Furthermore, an air sample taken in the face return will not give
a true indication of the conditions on the first face. It is much better from a
ventilation point of view to split the air at the loader gate with returns at
both ends of the face and to have the loader gate of large section so as to
reduce the air velocity.
 |
 |
|