14th November 1942, Page: 120, Column: 2 Steel Arch LiningsIn a written contribution to the discussion of the paper read by Dr. W. H. Evans on "Tests on Linings for Steel Arches" before the North Staffordshire Institute of Mining Engineers, Mr. W. H. N. Carter said from the aspect of supplies of materials it was important that no round timber of the critical sizes, from 3 inches to 6 inches in diameter, should be used other than as props. The paper gave useful comparisons, generally reassuring, of the behaviour of other materials, such as coverboards, small diameter timber, concrete and interlocking bricks, in lining or backing road supports. Dr. Evans dealt with concrete blocks so shaped as to make reinforcement unnecessary. Reinforced concrete blocks were, of course, used at several collieries in roadways well back from the face and in one case the colliery supplied the reinforcement in the form of scrap rope to the manufacturer. Another point seriously affecting the conservation of materials was that effective lagging between the flanges of the arches might permit a reduction in the weight of steel required. That such lining added to the strength of the arch was, of course, well known, but the measure of increase that could be obtained in that way had not always been realised.
|
|||||||||||||||||||
![]() |
||||||||
|