|
31st October 1942, Page: 102, Column: 1 Mine Gases And Gas TestingTesting for FiredampBy "Deputy." "If at any time it is found by the person for the time being in charge of the mine, or any part thereof, that, by reason of the presence of inflammable or noxious gases, or of any cause whatever, the mine or any place in the mine is dangerous, every workman shall be withdrawn from the mine or place found dangerous, and a fireman, examiner, or deputy, or other competent person authorised by the manager or under-manager for the purpose, shall inspect the mine or place found dangerous, and, if the danger arises from inflammable gas, shall inspect the mine or place with a locked safety-lamp, and in every case shall make a full and accurate report on the condition of the mine or place (Section 67 (1)). "A place shall be deemed to be dangerous if the percentage of inflammable gas in the general body of the air in that place is found to be two and a half or upwards, or, if situate in a part of the mine worked with naked lights, one and a quarter or upwards (Section 6J (2))." This section of the Coal Mines Act (1911) should be familiar to all firemen, examiners, or deputies, in order that the necessary precautions may be taken to prevent workmen entering, or remaining in, places which have been found unsafe due to the presence of inflammable gas. General Body of the Air. Firedamp escapes from the coal seam, and it may also escape from the roof or the floor, especially at, or near, the face of the workings. When the mine is ventilated by an adequate current of air the gas which exudes from the strata is diluted and carried off through the workings into the return airway, and thence to the upcast shaft. Such gas as enters the current of air passing through the mine becomes intimately mixed with the air and is said to be part of the general body of the air. The proportion of inflammable gas in the general body of the air varies from time to time during the day according to the rate at which the coal is broken down and loaded out. Accumulation of Firedamp. In the normal working of a colliery it is sometimes found that the air-current is not readily conducted into every part of the working, and, because of that, the requisite provision of a ventilating current may not be made, hence inflammable gas may accumulate in such places. Falls of roof may occur and the cavities thus formed may become filled with inflammable gas. In the normal course of working a seam by the longwall method, the roof is brought down in the roadways to make height and to provide the material necessary for building packs along the roadways. A natural consequence of the removal of the coal seam is that the roof subsides, and inflammable gas from the seam and the roof strata finds its way through the cracks in the roof into the space in front of the ripping. Being lighter than air firedamp rises into such cavities and may remain there until they are swept out by air-currents directed into them. Sometimes we find firedamp in concentrations at the ends of longwall faces, where the ventilating currents do not usually pass, unless special provisions are made for leading them right into the rib sides. In testing for firedamp we must therefore distinguish between firedamp in the general body of the air and firedamp which accumulates in places unswept by air-currents. In the former case it is right to estimate the percentage of firedamp in the air, but in the latter case no such estimation is possible, because the concentration of inflammable gas is greater the nearer we approach the roof. In that case the deputy should determine the extent of the accumulation so that he may judge the steps he should take for its safe removal into the return airway. Principle of the Safety-lamp Test. The presence of inflammable gas in mine air has a characteristic effect on the lowered flame of a safety-lamp. When a flame is placed in an atmosphere containing less inflammable gas than is necessary to form a lower-limit mixture (5.7 per cent.), it becomes surrounded by a zone of burning gas which may or may not be visible according to whether the flame has been reduced to non-luminous proportions or is of the normal brightness. The zone of burning gas, or cap, may not be distinguishable if the percentage of inflammable gas is very small, but there is little doubt that if the testing flame is small enough to be non-luminous, and the percentage of inflammable gas is as low as that specified in Section 67 (2) of the Coal Mines Act (1911), the surrounding zone of burning gas will be seen by a person of normal vision. In order to produce a suitable testing flame, the normal illuminating flame of the safety-lamp should bo reduced until it is almost non-luminous, when it will generally be found to be about one-tenth of an inch high. A reduced flame which is quite non-luminous is readily extinguished, and a reduced flame which is surmounted by a small speck of white flame, besides being more stable, tends to illumine the zone of burning gas surrounding the testing flame and render it all the more visible to the eye. In proceeding to test for an accumulation of firedamp it is enough to reduce the flame of the safety-lamp to about half its normal size, when much of the brightness of the flame will have been removed. Should firedamp be present in dangerous amounts the flame will be seen to lengthen, and it may spire into the gauze if there is much firedamp present. The Fuel Cap. When a refined spirit is used as fuel in a safety-lamp the reduced flame may become surrounded in fresh air by what appears to bo a zone of burning gas similar to that produced by the burning of firedamp. This arises from the burning of the vaporised spirit that is produced at the wick tube by seepage from the full chamber that forms the bottom of the lamp. Deputies should become familiar with the fuel cap produced in fresh air by the burning of the vapour, so that they may correctly estimate the percentage of inflammable gas by the height of the cap when the lamp is taken into air containing firedamp. Forms of Wick Tube. The burners of flame safety-lamps are of a great variety of shapes and sizes, but here we are content to refer to three of them. The circular wick tube of one of the newest of modern safety-lamps is 0.3" in diameter and double distilled colzalene is used as the fuel. This ensures a hot flame and a wick which does not readily become sooted. The flat wick tube of another safety-lamp which has long been used by deputies is 0.55" by 0.15", and in that case the fuel used is necessarily of a higher flash point, because the wick dips into the oil reservoir, thus tending to the more rapid vaporisation of the fuel. A bifold burner may have two tubes 0.15" in diameter at 0.25" centres and be designed to burn paraffin. Each type of burner is provided with a surrounding tube which is adjusted by a screw to adjust the testing flame to the required dimensions or state of luminosity. Consideration of these forms of burner leads to the recognition that the width of the testing flame is greater in the cases of the flat and bifold burners than in the case of the circular burner, and that most likely the heights of the caps produced by a given percentage of inflammable gas would be in proportion to the widths of the flames, but when allowance is made for the greater calorific value of the refined colzalene used in the lamp with the round burner it might be expected that the heights of the caps would be about equal for a given percentage of firedamp. Estimation of Percentage of Firedamp. Having arrived at a place where a test is to be made the deputy should lower the flame of the lamp until it is almost non-luminous and raise the lamp slightly above the level of the eyes to avoid reflection of the testing flame to the eyes. He may raise his hand to hide the testing flame, thus enabling a cap to be more easily seen. If there appears to be the formation of the base of a cap on the shoulders of the testing flame it may be assumed that there is about 1 per cent. of firedamp in the general body of the air. Trained observers are sometimes able to distinguish the base of a cap when the percentage of firedamp is as low as 0.5. If a lamp, with any of the wick tubes mentioned above, is placed in a 2 per cent. mixture of firedamp and air a cap one-quarter of an inch high would be most likely to be seen surmounting the testing flame, although in the case of the round wick burner the cap might be complete with 1½ per cent., but of less density than with 2 per cent. The height of the cap in a 3 per cent. mixture is generally found to be about ½-inch, and in a 4 per cent. mixture 1 inch. At 4½ per cent, the cap would spire up into the gauze and reach the top of it. As a rule, the caps given by percentages of firedamp between 2 and 4 are quite complete and easily seen on the lowered flame of a safety-lamp, and the cap may still be complete when the percentage of firedamp is 1½, but the cap given by 1¼ per cent. is definitely incomplete although the base of it is easily seen. Candidates for the Colliery Firemen's Certificate must not only show that they know how to test for firedamp, they must be able to see caps indicating tho presence of from 2 to 4 per cent. and be quite definite about the recognition of the 2 per cent. cap. In order that prospective candidates may have knowledge of the relationship between the height of cap and percentage of firedamp we reproduce the table first given by Prof. T. Gray in the Transactions of the Institution of Mining Engineers, Vol. 39.
Those determinations were made in a coal mine and the results were checked by chemical analyses. Accumulation Test. An accumulation of firedamp may be very dangerous to workmen, therefore it is all the more necessary that the deputy should determine the extent of it, so that he may know how best to remove it. It may be suspected in places unswept by the air-current, as in cavities in the roof, in rippings, and at rib sides. In approaching such a place the flame of the safety lamp should be turned down to half normal size, and then the lamp should be raised towards the roof as the deputy moves forward. Lengthening of the flame denotes the presence of firedamp in dangerous quantities. The accumulation should be approached from all sides to determine its extent, and if it cannot be removed immediately a fence should be erected in each approach to the place to prevent workmen straying into a dangerous atmosphere.
|
|||||||||||||||||||||||||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||