Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

22nd August 1942, Page: 37, Column: 1

Safety Provisions

Fire-fighting Underground

By "Tester."

When an officer of the London Fire Brigade expressed the view that there was nothing quite like water for fire-fighting, in peace as in war, he was backed by a very considerable experience of the use of water in the extinction of fires which had arisen from accidents and from the showers of "incendiaries" that fell from the sky during the Battle of Britain. Experience of mine fires has shown that the use of water in the extinction of underground fires may be the most efficient method, provided there is an adequate supply of water at a suitable pressure.

The fire-fighting regulations require that, in mines employing 100 or more persons, there shall always be available a sufficient supply of water together with efficient means of conveying it and delivering it promptly to every part of a mine where fire is liable to occur. As an alternative to delivering by pipe-lines and hose extensions water shall be delivered from water tanks or barrels by manual force pumps. In addition to a supply of water there shall also be an adequate supply of dry inert dust and sand, or sufficient portable fire extinguishers. As a general rule it will be found that the provisions made at collieries for fire-fighting are adequate, and that liberality has been displayed by the management in the amount and diversity of the materials provided, particularly where the fires are likely to occur in airways, or in places where there are means of ingress and egress, as on a longwall face.

The occurrence of an incipient fire in the gob may present a problem which cannot conveniently or expeditiously be solved with the provisions made in terms of the fire-fighting regulations. It is not contemplated in the regulations that inert dust or sand should be carried into a fire area by means of a stream of water under pressure, but G. C. Hutchison, a student member of the Mining Institute of Scotland, has in a most praiseworthy manner described how a fire which occurred in the waste of an abandoned section in the Lower Jersey seam, midway between two neighbouring collieries, was extinguished by pumping into the waste a mixture of sand and limestone dust in water. Mr. Hutchison's paper is to be found in the Transactions of the Institution of Mining Engineers, at page 369, Part 3, Volume XCVII (June, 1939).

Distribution of Water by Pipes.

In the days when it was customary to have a large number of ponies at work on the haulage of tubs from the workings to the shaft it was essential to the health of the animals that they should be provided with adequate fresh water, and that was most conveniently done by having a system of distributing the water by means of pipes leading from the surface, or from a lodgement in the shaft, inbye to the several districts in which ponies were employed. Malleable iron (or steel pipes with screwed or flanged joints) was taken down the shaft and along the roadways to points at which branch pipes with suitable valves were fitted. In many mines similar arrangements were made for conveying water to nozzles from which the water, sometimes in admixture with compressed air, was sprayed to allay the danger of coal dust deposits on the roof, floor, and sides of airways. Such a distribution system would lend itself to a simple adaptation by which hydrants could be fitted at certain intervals along the roadways. Hydrants might be fitted at intervals of 200 yards along the pipe lines, and at each hydrant there should be at least several lengths of fire hose aggregating a total length of 100 yards. With nozzles an inch in diameter it would be possible to provide a considerable supply of water, which would, of course, depend on the pressure head. The following table gives the approximate delivery of water from 1-inch nozzles at a variety of heads, the head being in feet and the discharge in gallons per second :—

Tanks or Barrels.

Emergency reserves of water can be readily transported from the main water supply near the shafts to points inbye by means of trains of water tanks, or barrels, each having a capacity of 100 gallons. Such trains should be stationed at the entrance to each district of the mine, and where power is transmitted by compressed air the tanks or barrels should be fitted with couplings by which they could be attached to the air supply, so that the water might be discharged from the receptacles through hoses and nozzles by the pressure of the air. Failing such an arrangement it would be necessary to provide double-manual pumps to enable the water to be delivered in the requisite quantities at the seat of the fire. In such a case as that described by Mr. Hutchison it would be necessary to have a power-driven pump capable of maintaining a high enough pressure to enable it to be used for the purpose of injecting dust or sand in water into the fire area.

Fire Stations.

No hard and fast rule can be laid down for the disposal of fire-stations about the mine, but it does seem desirable that they should be placed at vulnerable points, or at least near to points at which fires would be liable to occur. We have seen fire stations placed at intervals of about 600 yards on main roadways in proximity to road junctions, but such distances are mainly defined by the layout of the several districts of the mine.

The equipment provided at such fire-stations in a colliery will as a rule be standardised, and it might conceivably be as follows : 6 water buckets, 6 water carriers, 1 double-manual hand pump, together with 100 yards of hose and two duplex nozzles ; 6 two-gallon fire extinguishers, 2 picks, 2 spades, 2 right-angle bends with Gullick couplings, 1 roll of brattice cloth, 500 Hessian bags for carrying sand or dust; and, where an emergency supply of water is required, there should be a train of 6 water tanks or barrels. In addition to the equipment provided at each fire-station it would be necessary to provide buckets of sand, dust, and water, at each switchgear station, together with at least, one fire extinguisher.

Sand and Dust Dumps.

It seems desirable that there should be a dump for sand and inert dust near to each fire-station, so that in the event of an outbreak of fire all the fire-fighting equipment and material would be readily accessible to those persons who would be engaged in fighting the fire. Liberal supplies of dust and sand are especially necessary in mines where seams are liable to spontaneous combustion. It is rather fortunate that in all the British coalfields much is now known about the seams that are liable to spontaneous combustion, but in spite of that knowledge fire may occur in dry mines where it never was considered likely to occur.

Breathing Appliances.

We must make every provision possible for the safety of the fire-fighters, and on that account it is necessary that self-contained breathing appliances should be readily available to them, together with resuscitating appliances in case of need. It is exceedingly fortunate that in this respect we have in all our coalfields teams of trained men who are always available and ever ready to deal promptly with fire, whenever and wherever it occurs.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Hutchison, G. C.      



Related Articles

Pub.
Date
Article (Newspaper)
04 Apr 1942  Safety Provisions, Mine Air Analysis. — I (The Science and Art of Mining)
18 Apr 1942  Safety Provisions, Mine Air Analysis — II (The Science and Art of Mining)
02 May 1942  Safety Provisions, Mine Air Analysis — III (The Science and Art of Mining)
16 May 1942  Safety Provisions, Firedamp Detectors (The Science and Art of Mining)
30 May 1942  Safety Provisions, Coal Mines General Regulations (Lighting), 1934 (The Science and Art of Mining)
13 Jun 1942  Safety Provisions, Determination of Horizontal Candle-power (The Science and Art of Mining)
27 Jun 1942  Safety Provisions, Horizontal and Vertical Distribution of Light (The Science and Art of Mining)
11 Jul 1942  Safety Provisions, Fire-fighting Regulations (The Science and Art of Mining)
25 Jul 1942  Safety Provisions, Causes of Underground Fires (The Science and Art of Mining)
08 Aug 1942  Safety Provisions, Prevention and Extinction of Underground Fires (The Science and Art of Mining)
22 Aug 1942  Safety Provisions, Fire-fighting Underground (The Science and Art of Mining)

 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print