25th July 1942, Page: 19, Column: 2
Detonators
Dealing with the question of "Safe Opening and Determination of
Construction of Detonators" in U.S. Bureau of Mines Report of
Investigations 3594, Messrs. R. L. Grant and A. B. Coates, of the
Bureau Explosives Division, say that detonators are used to explode permissible
explosives, dynamites, or other high explosives. This explosion or detonation
is brought about by the energy which is liberated as a combination of
concussion and heat when the detonator is fired. In other words, "The
detonator is the key which unlocks the energy of a high explosive." Being
sensitive and latently dangerous, detonators must meet two primary requirements
: They must be safe to handle and must detonate when desired, thereby imparting
detonation to the explosive charge.
In the United States, the commonly accepted terms for classifying and
describing devices for initiating the detonation of high explosives are either
"blasting caps" or "electric blasting caps," depending on
whether these are fired by a length of fuse or by electrical means. In
appearance, a blasting cap is a small, cylindrical, copper capsule closed at
one end ; in the closed end is a charge or series of charges of explosives of
such a nature that when ignited by the spit of a fuse a detonating explosion
results. An electrical blasting cap is similar in external appearance, except
that the end of the capsule that is open in a blasting cap is closed by a plug,
through the centre of which pass two insulated electric wires ; internally it
is also similar to the blasting cap, but the explosive charge is detonated by
heat generated in a "bridge-wire" by the passage of an electric
current.
In the naming of detonators and their parts there is evident lack of a
systematic, widely accepted nomenclature as found in the literature and as
applied to these devices by the manufacturers and users. Consequently, there is
an ambiguity of terms that in many instances has caused confusion. For example,
the word "detonator" sometimes is used in the broad sense to include
generically both blasting caps and electric blasting caps ; sometimes it is
used to refer specifically to blasting caps fired with safety fuse ; again, it
is used in the sense of being synonymous with electric blasting cap.
The Authors of the Report say the following broad classification covers terms
that may be found in the literature or used in the field :—
Detonators or caps. — A. Blasting caps, plain blasting
caps, plain
detonators, fuse-fired detonators. B. Electric blasting caps, electric
detonators, or electric-fired detonators.
As a basis for primary reference, this classification may be simplified to the
following, which represents the minimum departure from common usage :—
Detonators. — A. Plain detonators (common term: Blasting
caps). B. Electric detonators (common term : Electric blasting caps).
1. Instantaneous.
2. Delay.
a. Vented.
b. Ventless.
Thus, the adjective "plain" is introduced to differentiate those
detonators that are fired by safety fuse from those that are fired by an
electric current.
 |
 |
|
Names mentioned in this article
|
 |
 |
| Name | Age | Occupation | Notes |
| Coates, A. B. | | U.S. Bureau of Mines | |
| Grant, R. L. | | U.S. Bureau of Mines | |