Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

11th July 1942, Page: 5, Column: 1

B.T.U. Values Of Coal

The discussion of "The Various B.T.U. Values of a Coal" is undertaken by Messrs. J. F. Barkley and L. B. Burdick, of the U.S. Bureau of Mines Fuel Economy Service, in Information Circular 7193. Appended are extracts.

The inherent heating value or the amount of heat that will be produced when a coal is completely burned is measured in British thermal units per pound of coal. This standard heat unit is the quantity of heat required to raise the temperature of 1 pound of water 1°F. at about 60°F. The amount of inherent heat is determined by burning a small quantity of the coal in a heat meter or calorimeter, which gives results in British thermal units. The value so determined is the total heat developed by complete burning, with all the products of combustion cooled down to the temperature of the calorimeter. The calorimeter is kept at about room temperature. This total heat is sometimes called the "high" or gross heat value, because it includes the latent heat given up by the water vapour in the products of combustion when the vapour condenses to water in the calorimeter. The heat as measured is reported as the heat of combustion at constant volume, since the burning is carried out in a tightly closed calorimeter chamber whose volume does not change.

The chemical elements in coal that produce essentially all the heat are carbon, hydrogen, and sulphur. Therefore, the B.T.U. value of a coal as shown by the calorimeter may be approximated by computation from Dulong's formula :

where C, H, O, and S represent the quantities (fractions, of a pound) of carbon, hydrogen, oxygen, and sulphur in 1 pound of coal. One pound of each element is considered to produce the quantity of heat expressed by the number preceding it in the formula. It is assumed that all oxygen in the coal is combined with hydrogen in the ratio of 8 : 1 to form water (H2O) ; hence, only the remaining uncombined hydrogen is available for producing heat. For anthracite, semianthracite, and bituminous coals the computed B.T.U. values are usually within 1½ per cent, of the values determined by the calorimeter. For sub-bituminous and lignitic coals the computed values often deviate as much as 5 per cent. Causes for these differences include: (1) The heating values given by the numbers in the formula may not be quite correct for the conditions; (2) all the oxygen may not be combined with hydrogen, as part may be combined with other substances, such as carbon ; (3) the percentage of oxygen in coal is determined by subtracting the sum of all the other substances found by analysis from 100 per cent., thus throwing all errors into the percentage of oxygen ; and (4) the production of heat from coal is not as simple as the formula indicates, since various heat reactions occur with other substances in the coal, such as the burning of the iron in the ash. The usefulness of the Dulong formula is quite limited. It is much simpler and cheaper to make a calorimeter test than to analyse for the various chemical elements in the coal. Formulae have been proposed at various times for the calculation of the heating value from the "proximate" analysis of the coal. The proximate analysis gives the moisture, volatile matter, fixed carbon, and ash. Such formulae are apt to give unreliable results.

There are various ways of considering the B.T.U. value of coal. It is ordinarily expressed as the B.T.U. per pound : (1) "As received" or "as sampled" ; (2) "moisture free" or "dry" ; (3) "moisture and ash-free" ; (4) "H" value ; (5) dry, "mineral matter free" ; (6) moist, "mineral matter free." For any one coal sample, all these values are related by values of the chemical analysis of the coal. If the moisture, ash, and sulphur contents are known, any one of these values may be calculated from any other.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Barkley, J. F.    U.S. Bureau of Mines  
Burdick, L. B.    U.S. Bureau of Mines  


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print