Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

11th July 1942, Page: 1, Column: 1

Electrical Hazards In Mechanised Mining

U.S. Survey of Problems

Extracts from U.S. Bureau of Mines Information Circular 7160 on "Mechanised Mining Brings New Electrical Hazards." The authors are electrical engineer and associate electrical engineer respectively at the Pittsburgh Central Experiment Station.

By E. J. Gleim and H. B. Brunot.

In the mining of coal the trend is toward more and more mechanisation. This increased use of machinery to replace hand labour is assuming many new forms and presents a constantly changing aspect. Safety engineers must be alert if the many electrical problems resulting from these new installations are to be handled safely. Some of these problems present possible electrical hazards that may be overlooked by the safety engineer unless they are called to his attention by one who has made a special study of the conditions.

The foregoing is especially true of conveyor systems of mining. The terms "conveyor systems" and "conveyor mining" are used to indicate those systems in which various types of conveyors are employed to transport coal away from the working place. In some mines this means complete elimination of track, cars, and locomotives. In others it means that conveyors take the coal from the working place to a convenient loading point, from which transportation is completed by cars and locomotives.

Under some of the modern systems a number of cuts are made in a working place each day with a mining machine where formerly only one cut was made. This suggests the possibility of liberating more gas than formerly in 24 hours in a given working place, with the probability that ventilation must receive greater consideration. Likewise, more coal dust will be thrown into suspension in the same period unless steps are taken to allay it, as by spraying the cutter bits with water while mining machines are in operation. It is essential to apply water and rock dust or take equally effective measures to safeguard against ignitions of dust.

Conveyor Mining Hazards.

The various schemes of mechanical mining that require the presence of several machines and a number of men in the same working place all at one time tend to enhance both the mechanical and electrical hazards. The object of the Circular is to indicate that the presence of two machines in one place may more than double the hazard from failure of insulation and to emphasise that increase in mechanisation must be accompanied by a commensurate increase in precautions to avoid unsafe conditions.

In recent years an increasing number of instances have been reported to the Bureau's engineers of trouble arising when two or more machines were present in the same working place at the game time. Hazards of this general nature are not new, but fortunately in the past have occurred more or less infrequently. These additional electrical hazards may be divided into two groups — open sparking between normally non-current-carrying parts and overheating of conductors that would not occur if the machine were alone.

As an example of the first group may be cited the possible results of a failure of insulation at or near the grounded terminal of a machine supplied from a grounded direct-current system. This may not seriously hamper operation of the machine. In fact, such an occurrence may not even become evident to the machine runner for an indefinite period in the ordinary course of work. Nevertheless, the machine is in a hazardous condition. If, as is so frequently true, the machine frame is not adequately grounded by a separate conductor of ample size any disturbance of the return circuit, such as might result from a broken or loose rail bond or dislodgment or loosening of the rail hook, may cause the frame to be charged to a dangerous potential. Under such circumstances the operator not only may receive a fatal shock, especially if he is also in contact with a conveyor or other fairly well-grounded machine frame, but open sparking between the faulty machine and the conveyor may, if explosive gas is present, lead to a disastrous explosion with the attendant destruction of life and property.

In addition to sparking, contact between a grounded direct current mining machine and a conveyor has been known to start the machine or cause it to continue running even after the controller has been disconnected. This is possible when the controller is connected only in the line that goes to the return.

Any ground in the machine may create such hazards ; but some grounds make their presence evident by causing distress in the machines' operation, by odour of burning insulation, or by stopping the machine entirely. These grounds may therefore sometimes prove less hazardous to life and property by making themselves manifest sooner and thus demanding correction.

Sources of Danger.

As an example of conditions that might result in overheating of conductors consider a coal-cutting machine, a conveyor, and a hand drill in the same room, the drill receiving its power through a connection on the mining machine. Failure of the drill insulation could provide a parallel path for the return current from the mining machine through the small drill cable. If the drill is not properly protected by a fuse the cable could be overheated. Again, when the drill frame is grounded to the cutting-machine frame to protect the driller from shock the ground wire from the drill might readily become a parallel path for return current from the cutting motor in case of insulation failure in the latter. Open sparking between the conveyor and drill or cutting-machine frames also is one of the possible sources of danger in such a combination. Moreover, should the rail connection become loose or dislodged it would be possible to burn the drill cable by current through the ground wire. It is for this reason that the Bureau requires the fusing of both sides of such branch circuits to drills and headlights.

Previous to conveyor mining it was customary to operate mining machines with cable-reel trucks, which served a double purpose. In addition to providing a means of transporting the machine from room to room they also carried a switch and fuse, or equivalent, to protect the machine. With the adoption of conveyor mining the truck was no longer required for moving the machine, and as track was not laid in the rooms the truck was too large and unwieldy to be taken into the rooms. Consequently there have been many installations in which the machine operator had no means other than the controller of cutting off the power near at hand. Furthermore, the overload protection, if any, was no nearer than the end of the trailing cable. Thus an unsafe operating condition arose. If a machine should suddenly "jump out" of its place because the bits strike some hard substance while the machine is being sumped in, it might get out of control and knock out posts or catch the operator. Without an independent switch for stopping the machine considerable damage or severe injury to men might result before some one could disconnect the trailing to stop it. In such emergencies, and especially when the coal seam is low, considerable time elapses before a man can travel 300 feet or more to reach the point where he can disconnect the cable.

Another hazard that must not be overlooked is the possibility of flashovers in drum controllers on some of the older-type 500-volt machines. Under certain conditions the arcing that follows the flashover can burn a hole in the controller case, and disconnecting the controller will not stop the flow of current. Here, again, the absence of a switch is a serious handicap to prompt action in an emergency.

As mechanisation has advanced the design of mining machinery has become progressively more complicated, until to-day there are single machines with as many as 40 explosion-proof compartments. Corresponding increase in the amount of wiring on these machines now makes adequate protection of the circuits between the explosion-proof enclosures one of the chief problems. Wiring must be so placed and protected by conduit and guards that mechanical injury or deterioration of rubber insulation from contact with oil is minimised. Adequate overload protection for the numerous branch circuits for small motors, headlights, and the control devices, must be devised and provided. This problem also is being solved successfully for any given machine as an individual unit.

Inspection of Equipment.

It cannot be emphasised too strongly that efforts to prevent mine explosions of electrical origin should not cease with the mere purchase of permissible equipment. Equipment that has been abused and neglected is no longer trustworthy as a safeguard against electrical ignition of gas or coal dust. The safety valve on a boiler, the safety catches on a mine cage, and the gauzes in a safety-lamp all must receive periodic inspection, cleaning, adjustment, and lubrication if they are to be relied upon to function as intended. The same is true of permissible equipment. If bolts are omitted, if unauthorised changes are made, if holes are burned or broken through walls of explosion-proof housings, and if cables are poorly spliced on such equipment, it can no longer be truly regarded as permissible because any one of these faulty conditions might cause an ignition. This demands well-trained electricians and mechanics who understand the safety features of permissible equipment, as well as for the correct supplies and replacement parts if the equipment is to be maintained properly.

Thorough inspection must include frequent checking of the insulation of machinery by means of suitable instruments such as "meggers" to find incipient faults before the insulation actually fails ; repair made promptly upon the basis of conscientious use of a megger is one of the best safeguards against electric shock.

Grounding methods must be studied carefully to guard against disaster from such insulation failures as may occur in spite of the best precautions. Some measure of protection against hazards resulting from the proximity and interconnection of several machines in the same locality is obtained by intelligent use of grounding conductors and fuses (or equivalent overload protection). In many instances such expedients alone are not sufficient to protect fully against the hazards introduced by concentration of electrical circuits and machinery.

Restricting Length of Exposed Cable.

Some attempt has been made to reduce the total amount of cable exposed in rooms. One system employs a main cable whose length when fully extended equals or nearly equals that of the completed room. The end toward the face terminates in one or more junction boxes with receptacles or sockets to take plugs attached to cables for the various machines. This permits restricting the length of the individual machine cables merely to that required for convenience in operation and movement of the several machines. In most cases 50-foot lengths are adequate for the purpose.

When shaker conveyors are used further reduction in amount of cable exposed in a room is obtained by the use of a multiple-circuit junction box. In one such system the junction box was placed at the entrance to the room, and three circuits were served, namely : (1) mining machine, (2) shaker conveyor, and (3) blower. As the conveyor drive and the blower were placed at or near the room entrance, the cables to them were relatively short. This left only the mining machine and conveyor control cable to be carried to the face. The mining-machine cable was taken through a fused box (mounted on the mining machine), in which the cable was tapped for a drill circuit, which was protected by this fused switch. In this system the mining machine and control circuits were carried on insulators fastened to the roof or to posts. By comparison with systems employing mobile loaders it is apparent that the system just described offers a much safer arrangement, as far as cables are concerned.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Brunot, H. B.    U.S. Bureau of Mines  
Gleim, E. J.    U.S. Bureau of Mines  


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print