Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

7th February 1942, Page: 230, Column: 1

Signalling On Haulage Roads

A paper on "Rationalisation of Colliery Electrical Equipment" has been read by Mr. J. A. B. Horsley, O.B.E., before the Institution of Electrical Engineers. Under the sub-head signalling it was remarked that signalling on haulage roads by means of electric bells supplied with current from primary batteries is probably coeval with the use of electric power for working the haulages. Trembler bells are universal and since 1913, or thereabouts, the design has generally included a spark-suppressing device, consisting of a non-inductive shunt, a closed-circuit insulated winding or a copper sleeve. On long roads a relay is used to counteract voltage drop in the line which, with rare exceptions, is constructed of bare galvanised iron wire.

The voltage used for signalling is limited by law to 25 volts, and for many years signalling bells and relays have been tested and certified as safe for use in firedamp, at first by the Home Office and since 1921 by the Mines Department of H.M. Board of Trade. Nevertheless, it was pointed out, there would seem to have been no attempt to standardise the resistance of such bells and relays, to say nothing of the variety in the spark-suppressing devices.

Bells, the products of nine manufacturers, are to be found in variety, with values of resistance ranging from 10 to 80 ohms, with intermediate values, neglecting fractional values, of 20, 25, 30, 60 and 60 ohms. Similarly, relays by seven manufacturers are to be found with values of resistance ranging from 20 to 500 ohms, with intermediate values of 50, 100, 200, 250 and 300 ohms. All of these bells and relays are required to be safe when tested at 25 volts, and the range of resistance values is doubtless dictated by the user who wishes to use some lower voltage. It should be possible to agree upon one value of resistance for all relays and upon two values of resistance at the most for bells, whereby substantial reduction in variety could be secured. It should be possible also to decide that one or other of the" 3 types of spark-suppressing device has the advantage on balance and to limit manufacture to that device.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Horsley, James Arthur Bennett      Whos Who Page


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print