13th December 1941, Page: 179, Column: 1 Survey Of Coal Utilisation FactorsUniversity of Illinois LecturesConcluded from page 162. Function of a Stoker. In the course of his paper on "The Designing of Domestic Boilers for Stoker Firing" Mr. W. B. Hughes* introduces some notes on the function of a stoker, over which the student may ponder to advantage and add somewhat to his general knowledge. Thus Mr. Hughes says :— The function of a stoker is to feed and burn a given amount of coal in a certain period of time in the most efficient manner, thereby releasing the greatest amount of heat energy. The function of the boiler is to absorb as much of this released heat energy as possible, before it reaches the chimney, to heat the water in the boiler or to make steam with which to supply the heating system. Thus, it is clear that for economical stoker-boiler operation, the work done by the stoker and boiler must be properly co-ordinated. In order to burn coal, a certain amount of oxygen is required, which in turn means that a certain amount of air containing this oxygen has to be supplied. Any air beyond this amount is excess air. Some excess air is always needed because the air distribution is never exact enough so that just the right amount of oxygen is always where it is needed, hence by supplying an excess amount of air there is everywhere enough oxygen to satisfy the requirements. This amount of excess air should, however, be kept as low as possible, because the larger the amount of excess air the larger the amount of gases rising from the fuel bed and the lower the gas temperature. It is quite obvious that a lump of coal can heat a small quantity of air to a higher temperature than a large quantity. A high temperature is desirable, however, as it keeps the fuel bed hot, and it is easier to transfer the heat to the boiler surfaces from a small amount of hot gases than from a large amount of cooler gases. There is still another reason why high temperature in the gases rising from the fuel bed is desirable. These gases usually contain some combustible matter which has to be burned by secondary air above the fuel bed. This combustible matter burns only if kept at a sufficiently high temperature. Naturally, the gases giving up heat to the boiler cool down, therefore the higher the initial temperature the longer before the gases cool below the ignition temperature of the combustible matter. It is desirable to have the gases at a temperature above the ignition temperature of the combustible matter in order to give the matter more time to burn out. This shows also that it is helpful to keep the heat loss from the gases low until the combustible matter is burned. This can be done by forcing the gases to travel either to the front or rear of the boiler before they are subject to the chilling effects of the flues. Uptakes in front or rear are therefore preferable to uptakes between sections, as in the latter case the gases are chilled too quickly, and the time given the combustible matter to burn out is reduced. In any event, only a part of the heat is transferred to the water in the firebox section of the boiler, and the combustion gases depart from the firebox at a high temperature. It becomes now the duty of the flue surfaces to extract this heat from the gases. Naturally, only such parts of the flue surfaces as come into contact with the flue gases can partake in such heat extraction. Surfaces hidden away in recesses or covered by baffle plates, etc., can obviously not partake in this heat extraction because they are out of the way of the gas stream. Therefore, a square foot of flue surface can contribute much, little, or nothing to the extraction of heat, depending on where it is located and how intimate its contact with the flue gas is. There are some more points to be considered in evaluating the effectiveness of flue surfaces. The longer the path the gases have to travel through the flues, the more time they have to lose their heat. Consequently, long flue travels are advantageous. The faster the gases move, the stronger is their scrubbing action, and, consequently, a square foot of surface in a fast moving gas stream receives more heat than one in a sluggish stream. The more the gas stream is sub-divided into small parallel streams, the better is the chance of the gas particles travelling in the core of the stream to reach the flue surfaces. Hence, it is advantageous to subdivide the flue passage. Of course, all these methods of improving the heat transfer have their limitations ; too much subdividing results in too small flues which are liable to clog up; too high flues lead to high draught resistance; too long flues make the boiler longer and more costly. A happy compromise has to be found to show all to the best advantage. From the foregoing it is obvious that a square foot of flue surface may act very differently, depending on just how well it is placed. While a square foot of flue surface is always 144 square inches of surface, it is by no means always 144 square inches of active surface. However, the active surface is what counts. Just hiding away somewhere in the boiler some surface which is not reached by the gases is just so much dead weight, adding nothing as far as the boiler performance is concerned. High CO2, indicates good combustion and good operation. Low CO2 indicates poor combustion and poor operation. Many boilers with an excess amount of inactive heating surface operate at a low stack temperature, but usually with low CO2. A reasonably high stack temperature, together with a high CO2 performance, indicates both efficient combustion and satisfactory boiler operation. * Manager of Stoker Division, Butler Manufacturing Company, Kansas City.
|
|||||||||||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||