6th September 1941, Page: 73, Column: 2
Importance Of Water-Gauge Readings
Writing in Information Circular 7037 of the U.S. Bureau of Mines,
Mr. G. W. Grove, of the Bureau Safety Division, says :—
Much could be said about the importance and meaning of water-gauge readings.
The pressure registered by a water-gauge and the volume of air being circulated
rather definitely indicate the capacity and condition of mine airways. A mine
ventilating system that requires an abnormally high water-gauge is generally
inefficient and expensive ; many persons consider water-gauge readings of 5 or
more inches as abnormally high.
High blood pressure in the human system is a sign of danger and indicates that
the heart is being overworked. Similarly, a high water-gauge in mine
ventilation indicates that too much power is being consumed in driving the mine
fan, probably because there are not enough airways, or they are inadequate in
size, or they are choked with falls ; in some cases probably all three of these
things are true. Although the water-gauge generally indicates certain things
with respect to the ventilation system, it cannot be depended upon to show
everything that is caused by changing conditions.
Many mine officials believe that the water-gauge will indicate all ventilating
conditions ; however, this is not true. Under some conditions a large fall may
completely block an entry or entries, or something may occur to
"short-circuit" the air completely, yet the water-gauge will not be
affected because the quantity of air flowing may be changed to such an extent
that little or no difference will be recorded by the water-gauge.
It is necessary, also, to consider the amount of air flowing and the amount of
power consumed by the fan motor when one interprets the record of the
water-gauge or a change in water-gauge readings.
 |
 |
|