6th September 1941, Page: 69, Column: 1
Air Flow Of Fan-Pipe Lines
In the introduction to the U.S. Bureau of Mines Report of Investigations 3531,
on "Air Flow at Discharge of Fan-Pipe Lines in Mines," Mr. G. E. McElroy,
supervising engineer of the mine ventilation section, says that
the ventilation of development faces in mines for diluting gas or dust
concentrations, and in hot mines for providing air-motion cooling effect, by
fan-pipe units discharging high-velocity streams of air close to the face, is
an important phase of mine ventilation. The effectiveness of such units depends
largely on the air flow distribution between the pipe discharge and the face, a
subject on which little definite information is available. A study of the air
flow from grills into rooms has provided some basic data, but under conditions
so different from mine fan-pipe installations in development ends that the data
are of doubtful application to mine installations, owing to differences in air
flow conditions.
The purpose of the report is to present and discuss the results of an initial
series of tests of a general investigation designed to yield definite laws and
design data for the discharge of fan-pipe lines in mines. The series was
planned to yield preliminary data on the effects of velocity of discharge, size
and shape of pipe, and adjacent Walls on the air flow distribution. Tests were
made on 10-inch pipe with seven different end conditions and one change of wall
condition. Changes in size and shape of discharge were made by short
transformation pieces directly at the discharge end, with the result that
effects due to contraction and expansion of the flow, which proved to be of
much greater importance than was expected, totally obscured any normal effects
due to size and shape.
Tests were made in a 100-foot drift, temporarily idle, that branches off the
main adit at the 350-foot point. Its cross-section ranged from a minimum of 6
by 7 feet to a maximum of 8 by 8 feet. The pipe discharge was about 55 feet
from the face. Air flow was induced by a small, radial-blade blower fan
belt-driven by a 4 H.P., single-cylinder gasoline engine. Tests were limited to
volumes of 1,000 and 1,500 cubic feet per minute. At 500 c.f.m. operation of
the fan engine was unsteady, and at 2.000 c.f.m. belt slip and engine vibration
prevented steady flow. The air pipe in place was a 10-inch, 20-gauge,
galvanised iron in 10-foot lengths, with swaged slip-joint ends. Joints were
wrapped with asphalted cloth and covered by draw bands that engaged the
swaging. They were airtight at the beginning and only minor leakages developed
later owing to heavy blasting concussions every few days. During test periods
the pipe line in the adit inbye the drift branch was disconnected and the open
end was blanked off with an airtight seal.
Following details of the tests Mr. McElroy summarises the results as
follows :—
Tests were made to determine velocity distributions in the stream discharged
from a 10-inch pipe line fitted with seven different end or discharge sections,
and results accurate enough for practical application were obtained. However,
changes of area and shape of discharge by means of relatively short
transformation pieces directly at the discharge yielded data on the effect of
contraction and expansion of the flow previous to discharge on velocity
distributions in the discharged-air stream, but not on the effect of area and
shape of pipe on the distribution, for which information additional tests will
be required.
Conditions of flow were found to be markedly different within about 4 feet of
the discharge (in which zone a complete alteration of velocity distribution
took place) than beyond this point, in which zone the type of distribution
remained constant and for which the decrease of velocity with distance was
found to be expressed correctly by the equation, log VR = log VRo — KL.
Values of constant K appeared to be a minimum for normal flow and higher for
either contracted or expanded discharge. Other tests have indicated that K also
varies directly as the square root of the area of the pipe line, a point that
should be confirmed.
The angle of expansion of the flow appeared to be constant — about
13° for uniform-area circular discharge and up to 16° for more
turbulent flow conditions.
Beyond about the 4-foot point the velocity distribution over the cross-section
appeared to be regular for unobstructed normal flow, with velocity varying
directly with the radius of the stream, except that in these tests, whether due
to test conditions or test apparatus, the nose of the air stream was flattened
somewhat. For normal flow conditions, maximum velocities were about 75 per
cent. of the peak velocities indicated by the side velocities ; for both
contracted and expanded discharge, the variation was much greater.
The effect of introducing a wall 1 foot off the centre line of the flow was to
increase the velocities of flow, first along the wall and then, with increasing
distance from the discharge, eventually throughout the air stream. The
resulting increases in maximum velocities were found also to follow the same
logarithmic law.
The flow was found to terminate rather abruptly — at about 24 feet for
1,000 c.f.m. and at 28 feet for 1,500 c.f.m., with but slight variations. This
condition has been ascribed to the back pressure required to pass the return
air 420 feet to surface and would thus not occur with discharge into an open
space, as from a grill into a room.
Enough data for very approximate calculations of change in quantity with
distance from discharge were obtained. Air is drawn into the expanding stream
at a rate roughly proportional to the discharged quantity times the square root
of the length. More complete test data are required for more accurate
computations of quantity changes.
 |
 |
|
Names mentioned in this article
|
 |
 |
| Name | Age | Occupation | Notes |
| McElroy, G. E. | | U.S. Bureau of Mines | |