17th May 1941, Page: 358, Column: 2
Building in Subsidence Areas
Discussing "Building Design in Subsidence Areas," Mr. G. Hurst,
B.Eng., explained to members of the Yorkshire branch of the
Institute of Mine Surveyors how excessive foundation area aggravated the
effects of subsidence. He suggested that large buildings and other structures
should be constructed in sections with definite vertical joints, so that
movement would be isolated and provision could be made for "jacking
up" to the original position. He contended that such designing would
obviate in some degree the necessity for support, and at the same time greater
areas of coal would be made available for working. Also the cost of working
round pillars of coal left to support buildings would be avoided.
 |
 |
|
Names mentioned in this article
|
 |
 |
| Name | Age | Occupation | Notes |
| Hurst, G. | | Mine Surveyor | |