17th May 1941, Page: 357, Column: 1 Electricity In MinesEvidence on the use of electricity in and about coal mines under the Coal Mines Act 1911 was taken during the sittings of the Royal Commission on Safety in Coal Mines, and in 1939, in pursuance of a recommendation of the Commission, a Departmental Committee was appointed to review the General Regulations. The chairman of the Committee was the late Professor William Cramp, D.Sc, and he was succeeded by Professor W. M. Thornton, O.B.E., D.Sc, D.Eng. Other members of the Committee were Mr. A. J. A. B. Horsley, O.B.E., Mr. A. M. Bell, and Mr. A. G. Connell. The Committee held nineteen meetings before the outbreak of war, and as the immediate introduction of new regulations then appeared to be impracticable took time to review tentative decisions and to prepare the report and the draft for the amended regulations, holding ten further meetings for those purposes. In their published Report (H.M. Stationery Office, price 1s. net) the Committee recommend a comprehensive revision of the existing General Regulations, which date from 1912, in order to bring them into harmony with modern electrical practice and to embody in them the higher standards of safety which are now attainable, and have appended to the Report a full draft of the revised regulations that it recommends for adoption. The Secretary for Mines, in Mines Department Circular No. 131, says he feels that so comprehensive a revision of the General Regulations cannot be undertaken at present, but he has arranged the publication of the Report in order to give mine owners, agents, managers and electrical engineers, as well as manufacturers of mining electrical equipment, the opportunity to study it and the draft revised regulations. He earnestly hopes that they will do so, and will apply the new code gradually, as opportunity offers, by adapting existing installations and practice and by installing new plant in compliance with it. In this way both mine managements and manufacturers of electrical equipment can, by their co-operation, hasten the general adoption of the higher standards of safety and practice recommended by the Committee, and by anticipating the requirements of the revised code of regulations they will facilitate its establishment in due course and save themselves trouble and expense. Extracts from the Report will be given in future issues of this Journal. A variety of subjects are discussed under the following general heads: (1) Colliery electrical staff; (2) ventilation standards ; (3) explosion hazard ; (4) fire hazard ; (5) quality of plant; (6) voltage limits ; (7) control of circuits ; (8) installation and maintenance of plant; (9) accidents attributed to the use of electricity; and (10) ancillary and amending Regulations. Proposals relating to the colliery electrical staff may be summarised thus :— (a) Duties. — Electricians should have specific responsibility, within the scope of their authority, for the installation, maintenance and testing of all apparatus and cables, including telephone and signalling circuits and appliances. (b) Authority. — Electricians in charge should have authority to stop immediately the use of any apparatus or cable observed to be in a dangerously defective condition, and they and their assistants should be required to report to an official of the mine, with a view to prompt remedy, any condition or use that is likely to affect the safety of the electrical installation.
|
|||||||||||||||||||||||||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||