|
17th May 1941, Page: 353, Column: 1 Dust Problem At Main Gate Transfer PointsReport of South Wales CommitteeThe third report has been issued by the Coal Dust Research Committee of the Monmouthshire and South Wales Coal Owners' Association, of which Mr. D. A. Hann is chairman. It deals with "The Suppression of Dust at (he Main Gate Transfer Point of a Conveyor District," and constitutes a frank discussion of everyday difficulties, though as regards conveyor systems it should not be assumed that South Wales is any worse than other coalfields. Dr. T. David Jones is the Director of Research, and in the introduction to the report there is an appreciation of the work of the Investigators, Mr. W. A. Terrell, M.Sc. (Underground), and Mr. J. Howard Griffiths, M.Sc. (Laboratory). A point of interest to which attention is directed is that of the width of the conveyor belts. This is accentuated by the intermittent method of loading usually adopted in the coalfield. It is suggested that after the war it may be well to review the whole position in regard to the width of the belts to be used from the standpoints of both longer life and reduction in the amount of dust produced. Activities at Transfer Point. Discussing the question of more dust being raised at transfer points in comparison with the rest of the coal face, the report states that coal, moving at a speed of about 150 feet per minute on the coal face belts, is suddenly discharged on to the main gate belt which has a speed of about 250 feet per minute, and travels in a direction at right angles to the coal face belts, so that it is inevitable that there is a good deal of rolling and spinning of the large coal. The transfer of the coal would take place much more smoothly if the face belts could be made to deliver the coal into chutes or slides arranged so that the coal pile is moving in the same direction as the main gate belt at the point of transfer between the conveyors. This implies that the actual design of the discharge ends of the coal face conveyors, is such as to deserve much more attention in the future than has been given to it in the past. The transfer point is a part of the conveyor system where there is always a good deal of activity, and is so crowded by the presence of machinery that only a small amount of room is available for the installation of dust suppression plant. Conditions are rendered more unfavourable on account of the fact that the discharge ends of the conveyors themselves must of necessity be left "open" as much as possible, not only to allow of free delivery of the coal, but to facilitate detail observation of the flow of coal. This is essential for efficient working of the coal face belts, and especially to allow of proper loading of the main gate belt by spreading the coal pile over its width and length, thereby reducing spillage of coal. Further, the transfer point is not fixed in position, but is moved forward regularly with the advance of the coal face, so that mobility is a factor which must greatly influence the design of any dust suppression apparatus. Again, to be successful in practice, it must be capable of being moved forward readily after each turnover of the conveyors, or moved backwards at a time when blasting has to be done at the ripping lip of the main gate roadway. Factors Affecting Dust Produced. It has been found that the dustiness of main gate transfer points varies considerably. In general the dust raised depends upon factors which can be conveniently divided into two categories as follows :— A. Dust raised which, owing to the dusty nature of a particular coal, cannot be prevented by the ordinary methods at present available for effecting transfer of the coal between the conveyors. The main factors influencing the amount of dust produced in this case is that of a dry friable coal producing a large percentage of small, and where the speed of discharge of the coal from the coal face conveyors is high in order to deal effectively with a large output. Under these conditions the transfer point usually presents a serious dust problem, and some form of dust collector would have to be installed to bring about an improvement. B. Dust raised which can either be greatly reduced or eliminated by a change in the practical conditions prevailing at the transfer point. The main factors affecting the amount of dust produced in this way are : (1) The type of coal face conveyors used ; (2) The correct setting of the discharge ends of the coal face conveyors ; (3) The maintenance of the conveyors in good condition at the transfer point; (4) The intermittent working of the conveyors ; (5) The position of the ripping lip of the main gate roadway, and its effect upon the velocity of the air-current at the transfer point ; (6) The direction of the air-currents ; (7) The quantity of air circulating. In about twenty conveyor districts investigated in the South Wales coalfield it was found that, in the majority of cases, the cause of the dustiness was due chiefly to one or more of the factors enumerated in category B, rather than that of category A. (1) In cases where the face conveyor nearest to the mnin gate conveyor is of the jigger type, it appears that less dust is raised during the transfer of the coal than is the case with a belt conveyor. This is because with a jigger conveyor a sudden fall of the coal can be avoided by the careful adjustment of plates to effect the transfer. (2) Greater attention should be paid to the correct setting of the conveyors, so as to reduce the height of fall of the coal to its absolute minimum. In some cases, it has been observed that the coal face conveyors have been set as much as twenty-four inches above the level of the main gate belt. Any reduction in the height of fall of the coal, no matter how small, will be well worth while from the point of view of the amount of dust produced. (3) At most of the transfer points examined, a source of much dust with belt conveyors was found to be the gap between the upper edge of the small transfer chute and the belt on the main drum of the coal face conveyor. A considerable amount of very small coal is continually carried through this gap by the motion of the belt and drum. (4) Intermittent loading of groups of trams at the main loading station is the system most generally adopted in South Wales collieries . . . The intermittent working of the conveyor belts causes more dust to be raised at the transfer point than would be the case if the belts were worked continuously throughout the coaling shift. The standard widths adopted for conveyor belts are usually a 20-inch coal face belt, and a 26-inch main gate belt, irrespective of the output of coal being dealt with. Whereas these standards might be suitable in cases where the system of continuous loading is adopted, it appears that they need revision in cases of intermittent loading. (5) It was found, frequently, that where the transfer point is very dusty in comparison with the rest of the coal face, the gate road ripping lip was some distance behind the coal face, and the resultant high velocity of the air-current was one of the causes of so much dust being produced, with the further disadvantage of greatly reducing the available space at a point of the conveyor system where ample room is essential, not only for the efficient working of the conveyors, but for eliminating one of the chief reasons for the discharge ends not being adjusted in their correct position relative to the main gate conveyor. It also renders more difficult the application of any apparatus for dust suppression. (6) The main gate transfer point is a part of the conveyor district where it is inevitable that changes in the direction of the air-current take place, producing eddy currents which tend to raise the very finest particles of dust from the coal as it is being transferred between the conveyors. (7) It now appears to have become more generally recognised that to control effectively, and also limit the amount of dust raised in any particular conveyor district, a correct balance must be made in practice between the velocity of the air and the quantity circulated. This rule is particularly applicable to the main gate transfer point, since the whole output of coal is dealt with at this point. Methods of Dust Suppression. In general, it is found that at main gate transfer points there are two sets of conditions, each of which requires separate treatment as to the possible methods of dust suppression to be adopted. Two cases met with in practice are : (1) Where the nature of the roof makes it impracticable to maintain the gate road rippings in advance of the transfer point, resulting in very little room for a dust collector to be installed and maintained. (2) Where it is possible to maintain the gate road rippings in advance of the transfer point, thereby affording sufficient room for the installation of a dust collector. In case (1), it appears that the best method yet adopted for reducing the dust is by the use of either water sprays or mist sprays, placed near the discharge ends of the coal face conveyors, so that the spray of water or mist is projected directly on the coal pile, at the point where most dust is being raised. Dust Collecting Apparatus. Of the many transfer points examined, it was observed that the quantity of dust produced was by far the greatest in a conveyor district in the "Yard" Seam, Cambrian Colliery, where the amount of dust raised at the transfer point was even greater than that at the main loading station of the district, which is contrary to the conditions existing in conveyor districts in general. A dust collecting apparatus was designed for the transfer point, made in the workshop at Cambrian Colliery, and after a preliminary test on the surface was installed underground. A hood is placed over the discharge ends of the face conveyors at the transfer point. The lower portion of the hood is made up of strips of conveyor belting, with slits cut in the belt so as to form a movable flap, which allows the coal to pass through at the point where it is discharged into the chute leading to the main gate conveyor. The dust produced during the discharge and transfer of the coal is drawn from the inside of the hood into a suitable length of 18-inch diameter tube, the necessary air flow being produced by a fan. The dust is allayed by means of a mist projector fixed in the end of the tube. It has been found that increased deposition of the dust is attained when the mist is blown, not only against the direction of the dust-laden air, but so that the motion of the air is turbulent and not stream-line. In the dust collector, a high degree of turbulence is imparted to the dust-laden air by means of the fan and a system of baffle plates in the tube. Efficiency of Extractor. From the results for two series of sample surveys before and after the installation of the dust extractor, it is possible to determine its effectiveness in reducing the dust concentration of the air in the region of the main gate transfer point. A graph shows the dust concentrations along the line of the coal face conveyors. Over a distance of 20 feet in the region of the transfer point the reduction in the amount of air-borne dust is about 87 per cent. A second graph shows the dust concentrations along the line of the main gate roadway, and over a length of the gate road from the coal face to a point 17 feet outbye the reduction in the amount of air borne dust is about 87 per cent. The report says these figures do not fully represent the actual efficiency of the dust extractor, as if, appears that it is quite effective in collecting all the dust raised during the actual process of transfer of the coal, from the face conveyor to the main gate conveyor. An important feature to which attention is directed is a very high dust concentration which exists between the tension end of the gate conveyor and the position of the coal face in the end of the main gate roadway. This region is one in which the air has only a slow eddying motion, and constitutes one of the "dead ends" of a conveyor district. Before the installation of the dust extractor, visibility was very bad in this part of the conveyor district, as a large amount of dust was being raised at this point from the working of the belt and drum in the tension box of the main gale conveyor. An important effect brought about by the dust extractor was to eliminate the stagnation of the air in this region, the dust-laden air being constantly drawn towards the hood of the dust extractor, resulting in a considerable reduction in the dust concentration. With the dust extractor working, visibility was greatly improved in the region of the transfer point, and the appreciation shown by the workmen and officials of the dust extractor was considerable.
|
|||||||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||