19th April 1941, Page: 327, Column: 2
Underground Supports
Dealing with the question of "Suitability of Supports Used
Underground," at the January meeting of the South African Institution of
Engineers, Mr. J. W. Bowen, M.Sc, recalled that various types of
concrete pipes and iron rings were made and a number of them were tested by
Professor Walker of the Witwatersrand University in 1927. Pressures of
10 to 15 tons were sufficient to break some of the concrete pipes, whereas some
of the telescopic iron pipes withstood a load of 290 tons. In view of the
results obtained, further investigations were carried out by Professor
Walker and Mr. Gimkey. A number of mild steel pipes of varying
diameters and re-entrant telescopic pipes were sand-filled and placed under
load. The maximum load taken by a sand-filled, 12-inch mild stool pipe 3 feet
long, ¼ inch thick, was approximately 300 tons. Further tests wore carried
out on sand-filled, telescopic, reinforced concrete pipes, concrete discs and
timber packs. Maximum pressures of 500 tons were applied and from graphs it
appears that the majority of the supports tested were in a reasonably sound
condition at this load. It appears that the maximum load available was 500
tons, while photographs indicate that the maximum bearing surface that could be
tested was approximately 4 square feet.
Mr. Bowen said the question of the suitability of the various types of
support used underground has always been a contentious one. This has led to the
introduction of various types of support, without due consideration being given
to their suitability for the purpose for which they are used. The object of
using support is to enable miners to extract the ore required from a stope in
safety. To be practical the method of support adopted must be economical.
Some confusion exists in regard to the moaning of the term
"strength." In a broad sense strength, the Author says, implies all
the properties which enable wood or other materials to resist different forces
or loads. In a restricted sense strength may apply to any one particular
property, in which case the name of the property should be stated. If the
individual strength properties of one timber were related it would be possible
to use the term for a particular timber, but unfortunately there is not always
a relationship between the various strength properties of the one wood. In some
cases the modulus of rupture of one timber is much greater than that of another
timber, and yet the impact strength is much lower. In Mr. Bowen's work
the term "strength," in the case of poles and columns, applies to the
maximum crushing load centrally applied which the pole or column is able to
withstand. In the case of pigsties, chock mats and Sloan-wire packs, the term
is applied to the ratio, load over compression. With timber mats the property
which is really being determined is the compression perpendicular to grain. In
standard tests this property is determined by impressing a 2-inch steel plate
into a standard test piece and determining the stress at proportional limit. In
the case of timber chock mats, stress at proportional limit is almost
impossible to determine. In view of this it was considered advisable to give
the load taken by the pack at a 25 and 50 per cent. compression. The mechanical
properties of timber are appreciably affected by the duration of loading. It is
well known that if the modulus of rupture of a sample after five minutes load
is taken as 100, after 10 years' duration it may have dropped to 50.
 |
 |
|
Names mentioned in this article
|
 |
 |
| Name | Age | Occupation | Notes |
| Bowen, J. W. | | | |
| Gimkey, S. F. | | | |
| Walker, —, Prof. | | | |