19th April 1941, Page: 327, Column: 1
Dust Sampling On The Rand
The Journal for December of the Chemical, Metallurgical and Mining Society of
South Africa is devoted to "A Critical Review of Dust Sampling Methods
Employed in Witwatersrand Gold Mines," by J. de V. Lambrechts, two
methods of dust sampling being discussed, namely, those utilising respectively
the Konimeter and the Thermal Precipitator. These are the only instruments
generally in use on the Witwatersrand for this purpose.
The sugar-tube gravimetric method, which has been in use since about 1912, and
which had yielded very valuable information for many years, was inevitably
discarded in 1938.
Since 1916 the Konimeter has been very closely associated with dust control in
Witwatersrand mines, and the method of using it has undergone various changes.
Yet it has always been accepted that on an average the Konimeter does indicate,
even if only very approximately, the silicosis risk to which persons are
exposed underground, and it can be claimed that in general actual results, as
reflected by silicosis incidence rates, have borne out this assumption.
In 1934 the Thermal Precipitator was introduced to dust sampling. The
Konimeter, however, remains the most widely used dust-sampling instrument in
Witwatersrand mines and, in the view of the Author, with certain alterations in
technique its usefulness has under present-day mining conditions probably
become greater than ever before, not only for routine work, but if necessary
also for critical investigations.
At the same time the Thermal Precipitator has probably come to stay, since its
value for critical investigations is undisputed. It depends for its action on
the fact that normally a dust-free zone surrounds a hot body. In practice the
hot body consists of an electrically heated wire ; the air to be sampled is
aspirated over the hot wire and, due to the inability of the dust particles to
penetrate the dust-free zone, they are deposited on glass cover-slips, which
are placed parallel to and in close proximity to the hot wire.
Up till now the dust records have been examined and counted under direct
illumination at a magnification of 1,000 to 1,500, using a 13 N.A.
oil-immersion objective.
There are two main types of the Konimeter in use on the Witwatersrand. Very
briefly, five cubic centimetres of dust-laden air is impinged at a velocity of
30-100 metres per second through a circular orifice or jet on to a jelly-coated
glass slide where the dust particles adhere in the form of a "spot."
The spots are "counted" at a magnification of about 150, using a form
of oblique or darkfield illumination obtained under standardised conditions.
For both the Thermal Precipitator and the Konimeter, dust counts are expressed
as particles per cubic centimetre, commonly abbreviated to p.p.c.c.
 |
 |
|